Synthetic Jet Cooling Part II: Experimental Results of an Acoustic Dipole Cooler
The paper discusses experimental results for a typical embodiment of synthetic jet cooling technology: an acoustic dipole cooler comprised of a standard loudspeaker in a housing provided with two pipes. A transient measurement set up is used to measure the average heat transfer coefficient based on...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The paper discusses experimental results for a typical embodiment of synthetic jet cooling technology: an acoustic dipole cooler comprised of a standard loudspeaker in a housing provided with two pipes. A transient measurement set up is used to measure the average heat transfer coefficient based on cooling a 5*5 cm 2 metal plate. Heat transfer and noise results are presented for a range of frequencies, pipe lengths and diameters. The results are compared with a standard 60*60 mm fan. It is concluded that, at least for the cases studied, the synthetic jet is superior on all fronts: heat transfer performance, noise level and dissipated power. |
---|---|
ISSN: | 1065-2221 2577-1000 |