Application of Reset Voltage Feedback for Droop Minimization in the Unidirectional Current Pulse Transformer

This paper investigates the application of reset voltage feedback for reducing errors due to droop in the signal derived from a current transformer sensing unidirectional current pulses in switched-mode power converter applications. Droop is minimised by applying a correcting voltage in series with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power electronics 2008-03, Vol.23 (2), p.591-599, Article 591
Hauptverfasser: McNeill, N., Gupta, N.K., Burrow, S.G., Holliday, D., Mellor, P.H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper investigates the application of reset voltage feedback for reducing errors due to droop in the signal derived from a current transformer sensing unidirectional current pulses in switched-mode power converter applications. Droop is minimised by applying a correcting voltage in series with the transformer's output terminals during the current pulse. The magnitude of the correcting voltage is based on the transformer's reset voltage sensed during the power converter's previous switching cycles. A model of the scheme is presented and a circuit is implemented. Reductions in both peak and average current droop are demonstrated.
ISSN:0885-8993
1941-0107
DOI:10.1109/TPEL.2007.915662