Modeling respiratory motion variations in the 4D NCAT phantom
The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution low...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4533 |
---|---|
container_issue | |
container_start_page | 4531 |
container_title | |
container_volume | 6 |
creator | Segars, W.P. Mori, S. Chen, G.T.Y. Tsui, B.M.W. |
description | The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution lower than that offered by more advanced CT scanners and consisted of only four time frames that did not adequately cover normal tidal breathing.We further develop the 4D NCAT to more accurately model normal and abnormal states of respiration. Over two- hundred sets of 4D respiratory gated CT image data from normal and abnormal patients obtained from the Massachusetts General Hospital were used to characterize variations in the respiratory motion. Each dataset contains twenty time frames over the respiratory cycle with the patient breathing normally.With the improved resolution and better coverage of tidal breathing, this data was used to improve the respiratory model of the 4D NCAT phantom. Using automatic and semiautomatic techniques, the different respiratory structures were segmented from each time frame of each CT dataset. The time series of segmented structures were used to characterize the respiratory motion in each case. From an analysis of all normal and abnormal patient datasets, we determined the range of sizes and shapes of the right and left lungs and the range in motion (expansion in the anterior and inferior (diaphragm)directions)in the different lung regions. This analysis was used to further parameterize the general respiratory model of the 4D NCAT to more realistically model normal and abnormal variations in anatomy and in the respiratory motion. With the ability to model variations in the respiratory motion indicative of a patient population, the phantom will be a great resource to investigate the effects of respiratory motion on medical imaging and to develop compensation methods for these effects. |
doi_str_mv | 10.1109/NSSMIC.2007.4437117 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4437117</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4437117</ieee_id><sourcerecordid>4437117</sourcerecordid><originalsourceid>FETCH-LOGICAL-i105t-214149f44df6e5d351f6f3a53222bcf241292e59bc7944157f16eccf81a1759a3</originalsourceid><addsrcrecordid>eNpFkMtOwzAURM1LIi18QTf-gQTf6-u4XrCoQoFKbVm0rCs3salR85ATIfXvAVGJ1YzOSGcxjE1AZADCPKw3m9WiyFAInRFJDaAv2AgIiYRBKS9ZgkrrVEzRXP0PqK5ZAj8wlbmiWzbq-08hUEiihD2u2sodQ_PBo-u7EO3QxhOv2yG0Df-yMdjf1vPQ8OHgOD3xdTHb8u5gm6Gt79iNt8fe3Z9zzN6f59viNV2-vSyK2TININSQIhCQ8USVz52qpAKfe2mVRMR96ZEADTpl9qU2RKC0h9yVpZ-CBa2MlWM2-fMG59yui6G28bQ7fyC_AcsISyY</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Modeling respiratory motion variations in the 4D NCAT phantom</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Segars, W.P. ; Mori, S. ; Chen, G.T.Y. ; Tsui, B.M.W.</creator><creatorcontrib>Segars, W.P. ; Mori, S. ; Chen, G.T.Y. ; Tsui, B.M.W.</creatorcontrib><description>The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution lower than that offered by more advanced CT scanners and consisted of only four time frames that did not adequately cover normal tidal breathing.We further develop the 4D NCAT to more accurately model normal and abnormal states of respiration. Over two- hundred sets of 4D respiratory gated CT image data from normal and abnormal patients obtained from the Massachusetts General Hospital were used to characterize variations in the respiratory motion. Each dataset contains twenty time frames over the respiratory cycle with the patient breathing normally.With the improved resolution and better coverage of tidal breathing, this data was used to improve the respiratory model of the 4D NCAT phantom. Using automatic and semiautomatic techniques, the different respiratory structures were segmented from each time frame of each CT dataset. The time series of segmented structures were used to characterize the respiratory motion in each case. From an analysis of all normal and abnormal patient datasets, we determined the range of sizes and shapes of the right and left lungs and the range in motion (expansion in the anterior and inferior (diaphragm)directions)in the different lung regions. This analysis was used to further parameterize the general respiratory model of the 4D NCAT to more realistically model normal and abnormal variations in anatomy and in the respiratory motion. With the ability to model variations in the respiratory motion indicative of a patient population, the phantom will be a great resource to investigate the effects of respiratory motion on medical imaging and to develop compensation methods for these effects.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 1424409225</identifier><identifier>ISBN: 9781424409228</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 1424409233</identifier><identifier>EISBN: 9781424409235</identifier><identifier>DOI: 10.1109/NSSMIC.2007.4437117</identifier><language>eng</language><publisher>IEEE</publisher><subject>Anatomy ; Biomedical imaging ; Computed tomography ; Hospitals ; Humans ; Image segmentation ; Imaging phantoms ; Lungs ; Motion analysis ; Spline</subject><ispartof>2007 IEEE Nuclear Science Symposium Conference Record, 2007, Vol.6, p.4531-4533</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4437117$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4437117$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Segars, W.P.</creatorcontrib><creatorcontrib>Mori, S.</creatorcontrib><creatorcontrib>Chen, G.T.Y.</creatorcontrib><creatorcontrib>Tsui, B.M.W.</creatorcontrib><title>Modeling respiratory motion variations in the 4D NCAT phantom</title><title>2007 IEEE Nuclear Science Symposium Conference Record</title><addtitle>NSSMIC</addtitle><description>The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution lower than that offered by more advanced CT scanners and consisted of only four time frames that did not adequately cover normal tidal breathing.We further develop the 4D NCAT to more accurately model normal and abnormal states of respiration. Over two- hundred sets of 4D respiratory gated CT image data from normal and abnormal patients obtained from the Massachusetts General Hospital were used to characterize variations in the respiratory motion. Each dataset contains twenty time frames over the respiratory cycle with the patient breathing normally.With the improved resolution and better coverage of tidal breathing, this data was used to improve the respiratory model of the 4D NCAT phantom. Using automatic and semiautomatic techniques, the different respiratory structures were segmented from each time frame of each CT dataset. The time series of segmented structures were used to characterize the respiratory motion in each case. From an analysis of all normal and abnormal patient datasets, we determined the range of sizes and shapes of the right and left lungs and the range in motion (expansion in the anterior and inferior (diaphragm)directions)in the different lung regions. This analysis was used to further parameterize the general respiratory model of the 4D NCAT to more realistically model normal and abnormal variations in anatomy and in the respiratory motion. With the ability to model variations in the respiratory motion indicative of a patient population, the phantom will be a great resource to investigate the effects of respiratory motion on medical imaging and to develop compensation methods for these effects.</description><subject>Anatomy</subject><subject>Biomedical imaging</subject><subject>Computed tomography</subject><subject>Hospitals</subject><subject>Humans</subject><subject>Image segmentation</subject><subject>Imaging phantoms</subject><subject>Lungs</subject><subject>Motion analysis</subject><subject>Spline</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>1424409225</isbn><isbn>9781424409228</isbn><isbn>1424409233</isbn><isbn>9781424409235</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpFkMtOwzAURM1LIi18QTf-gQTf6-u4XrCoQoFKbVm0rCs3salR85ATIfXvAVGJ1YzOSGcxjE1AZADCPKw3m9WiyFAInRFJDaAv2AgIiYRBKS9ZgkrrVEzRXP0PqK5ZAj8wlbmiWzbq-08hUEiihD2u2sodQ_PBo-u7EO3QxhOv2yG0Df-yMdjf1vPQ8OHgOD3xdTHb8u5gm6Gt79iNt8fe3Z9zzN6f59viNV2-vSyK2TININSQIhCQ8USVz52qpAKfe2mVRMR96ZEADTpl9qU2RKC0h9yVpZ-CBa2MlWM2-fMG59yui6G28bQ7fyC_AcsISyY</recordid><startdate>200710</startdate><enddate>200710</enddate><creator>Segars, W.P.</creator><creator>Mori, S.</creator><creator>Chen, G.T.Y.</creator><creator>Tsui, B.M.W.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200710</creationdate><title>Modeling respiratory motion variations in the 4D NCAT phantom</title><author>Segars, W.P. ; Mori, S. ; Chen, G.T.Y. ; Tsui, B.M.W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i105t-214149f44df6e5d351f6f3a53222bcf241292e59bc7944157f16eccf81a1759a3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Anatomy</topic><topic>Biomedical imaging</topic><topic>Computed tomography</topic><topic>Hospitals</topic><topic>Humans</topic><topic>Image segmentation</topic><topic>Imaging phantoms</topic><topic>Lungs</topic><topic>Motion analysis</topic><topic>Spline</topic><toplevel>online_resources</toplevel><creatorcontrib>Segars, W.P.</creatorcontrib><creatorcontrib>Mori, S.</creatorcontrib><creatorcontrib>Chen, G.T.Y.</creatorcontrib><creatorcontrib>Tsui, B.M.W.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Segars, W.P.</au><au>Mori, S.</au><au>Chen, G.T.Y.</au><au>Tsui, B.M.W.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Modeling respiratory motion variations in the 4D NCAT phantom</atitle><btitle>2007 IEEE Nuclear Science Symposium Conference Record</btitle><stitle>NSSMIC</stitle><date>2007-10</date><risdate>2007</risdate><volume>6</volume><spage>4531</spage><epage>4533</epage><pages>4531-4533</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>1424409225</isbn><isbn>9781424409228</isbn><eisbn>1424409233</eisbn><eisbn>9781424409235</eisbn><abstract>The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution lower than that offered by more advanced CT scanners and consisted of only four time frames that did not adequately cover normal tidal breathing.We further develop the 4D NCAT to more accurately model normal and abnormal states of respiration. Over two- hundred sets of 4D respiratory gated CT image data from normal and abnormal patients obtained from the Massachusetts General Hospital were used to characterize variations in the respiratory motion. Each dataset contains twenty time frames over the respiratory cycle with the patient breathing normally.With the improved resolution and better coverage of tidal breathing, this data was used to improve the respiratory model of the 4D NCAT phantom. Using automatic and semiautomatic techniques, the different respiratory structures were segmented from each time frame of each CT dataset. The time series of segmented structures were used to characterize the respiratory motion in each case. From an analysis of all normal and abnormal patient datasets, we determined the range of sizes and shapes of the right and left lungs and the range in motion (expansion in the anterior and inferior (diaphragm)directions)in the different lung regions. This analysis was used to further parameterize the general respiratory model of the 4D NCAT to more realistically model normal and abnormal variations in anatomy and in the respiratory motion. With the ability to model variations in the respiratory motion indicative of a patient population, the phantom will be a great resource to investigate the effects of respiratory motion on medical imaging and to develop compensation methods for these effects.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2007.4437117</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1082-3654 |
ispartof | 2007 IEEE Nuclear Science Symposium Conference Record, 2007, Vol.6, p.4531-4533 |
issn | 1082-3654 2577-0829 |
language | eng |
recordid | cdi_ieee_primary_4437117 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Anatomy Biomedical imaging Computed tomography Hospitals Humans Image segmentation Imaging phantoms Lungs Motion analysis Spline |
title | Modeling respiratory motion variations in the 4D NCAT phantom |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T04%3A22%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Modeling%20respiratory%20motion%20variations%20in%20the%204D%20NCAT%20phantom&rft.btitle=2007%20IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record&rft.au=Segars,%20W.P.&rft.date=2007-10&rft.volume=6&rft.spage=4531&rft.epage=4533&rft.pages=4531-4533&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=1424409225&rft.isbn_list=9781424409228&rft_id=info:doi/10.1109/NSSMIC.2007.4437117&rft_dat=%3Cieee_6IE%3E4437117%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424409233&rft.eisbn_list=9781424409235&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4437117&rfr_iscdi=true |