Modeling respiratory motion variations in the 4D NCAT phantom

The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution low...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Segars, W.P., Mori, S., Chen, G.T.Y., Tsui, B.M.W.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4533
container_issue
container_start_page 4531
container_title
container_volume 6
creator Segars, W.P.
Mori, S.
Chen, G.T.Y.
Tsui, B.M.W.
description The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution lower than that offered by more advanced CT scanners and consisted of only four time frames that did not adequately cover normal tidal breathing.We further develop the 4D NCAT to more accurately model normal and abnormal states of respiration. Over two- hundred sets of 4D respiratory gated CT image data from normal and abnormal patients obtained from the Massachusetts General Hospital were used to characterize variations in the respiratory motion. Each dataset contains twenty time frames over the respiratory cycle with the patient breathing normally.With the improved resolution and better coverage of tidal breathing, this data was used to improve the respiratory model of the 4D NCAT phantom. Using automatic and semiautomatic techniques, the different respiratory structures were segmented from each time frame of each CT dataset. The time series of segmented structures were used to characterize the respiratory motion in each case. From an analysis of all normal and abnormal patient datasets, we determined the range of sizes and shapes of the right and left lungs and the range in motion (expansion in the anterior and inferior (diaphragm)directions)in the different lung regions. This analysis was used to further parameterize the general respiratory model of the 4D NCAT to more realistically model normal and abnormal variations in anatomy and in the respiratory motion. With the ability to model variations in the respiratory motion indicative of a patient population, the phantom will be a great resource to investigate the effects of respiratory motion on medical imaging and to develop compensation methods for these effects.
doi_str_mv 10.1109/NSSMIC.2007.4437117
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4437117</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4437117</ieee_id><sourcerecordid>4437117</sourcerecordid><originalsourceid>FETCH-LOGICAL-i105t-214149f44df6e5d351f6f3a53222bcf241292e59bc7944157f16eccf81a1759a3</originalsourceid><addsrcrecordid>eNpFkMtOwzAURM1LIi18QTf-gQTf6-u4XrCoQoFKbVm0rCs3salR85ATIfXvAVGJ1YzOSGcxjE1AZADCPKw3m9WiyFAInRFJDaAv2AgIiYRBKS9ZgkrrVEzRXP0PqK5ZAj8wlbmiWzbq-08hUEiihD2u2sodQ_PBo-u7EO3QxhOv2yG0Df-yMdjf1vPQ8OHgOD3xdTHb8u5gm6Gt79iNt8fe3Z9zzN6f59viNV2-vSyK2TININSQIhCQ8USVz52qpAKfe2mVRMR96ZEADTpl9qU2RKC0h9yVpZ-CBa2MlWM2-fMG59yui6G28bQ7fyC_AcsISyY</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Modeling respiratory motion variations in the 4D NCAT phantom</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Segars, W.P. ; Mori, S. ; Chen, G.T.Y. ; Tsui, B.M.W.</creator><creatorcontrib>Segars, W.P. ; Mori, S. ; Chen, G.T.Y. ; Tsui, B.M.W.</creatorcontrib><description>The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution lower than that offered by more advanced CT scanners and consisted of only four time frames that did not adequately cover normal tidal breathing.We further develop the 4D NCAT to more accurately model normal and abnormal states of respiration. Over two- hundred sets of 4D respiratory gated CT image data from normal and abnormal patients obtained from the Massachusetts General Hospital were used to characterize variations in the respiratory motion. Each dataset contains twenty time frames over the respiratory cycle with the patient breathing normally.With the improved resolution and better coverage of tidal breathing, this data was used to improve the respiratory model of the 4D NCAT phantom. Using automatic and semiautomatic techniques, the different respiratory structures were segmented from each time frame of each CT dataset. The time series of segmented structures were used to characterize the respiratory motion in each case. From an analysis of all normal and abnormal patient datasets, we determined the range of sizes and shapes of the right and left lungs and the range in motion (expansion in the anterior and inferior (diaphragm)directions)in the different lung regions. This analysis was used to further parameterize the general respiratory model of the 4D NCAT to more realistically model normal and abnormal variations in anatomy and in the respiratory motion. With the ability to model variations in the respiratory motion indicative of a patient population, the phantom will be a great resource to investigate the effects of respiratory motion on medical imaging and to develop compensation methods for these effects.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 1424409225</identifier><identifier>ISBN: 9781424409228</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 1424409233</identifier><identifier>EISBN: 9781424409235</identifier><identifier>DOI: 10.1109/NSSMIC.2007.4437117</identifier><language>eng</language><publisher>IEEE</publisher><subject>Anatomy ; Biomedical imaging ; Computed tomography ; Hospitals ; Humans ; Image segmentation ; Imaging phantoms ; Lungs ; Motion analysis ; Spline</subject><ispartof>2007 IEEE Nuclear Science Symposium Conference Record, 2007, Vol.6, p.4531-4533</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4437117$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4437117$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Segars, W.P.</creatorcontrib><creatorcontrib>Mori, S.</creatorcontrib><creatorcontrib>Chen, G.T.Y.</creatorcontrib><creatorcontrib>Tsui, B.M.W.</creatorcontrib><title>Modeling respiratory motion variations in the 4D NCAT phantom</title><title>2007 IEEE Nuclear Science Symposium Conference Record</title><addtitle>NSSMIC</addtitle><description>The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution lower than that offered by more advanced CT scanners and consisted of only four time frames that did not adequately cover normal tidal breathing.We further develop the 4D NCAT to more accurately model normal and abnormal states of respiration. Over two- hundred sets of 4D respiratory gated CT image data from normal and abnormal patients obtained from the Massachusetts General Hospital were used to characterize variations in the respiratory motion. Each dataset contains twenty time frames over the respiratory cycle with the patient breathing normally.With the improved resolution and better coverage of tidal breathing, this data was used to improve the respiratory model of the 4D NCAT phantom. Using automatic and semiautomatic techniques, the different respiratory structures were segmented from each time frame of each CT dataset. The time series of segmented structures were used to characterize the respiratory motion in each case. From an analysis of all normal and abnormal patient datasets, we determined the range of sizes and shapes of the right and left lungs and the range in motion (expansion in the anterior and inferior (diaphragm)directions)in the different lung regions. This analysis was used to further parameterize the general respiratory model of the 4D NCAT to more realistically model normal and abnormal variations in anatomy and in the respiratory motion. With the ability to model variations in the respiratory motion indicative of a patient population, the phantom will be a great resource to investigate the effects of respiratory motion on medical imaging and to develop compensation methods for these effects.</description><subject>Anatomy</subject><subject>Biomedical imaging</subject><subject>Computed tomography</subject><subject>Hospitals</subject><subject>Humans</subject><subject>Image segmentation</subject><subject>Imaging phantoms</subject><subject>Lungs</subject><subject>Motion analysis</subject><subject>Spline</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>1424409225</isbn><isbn>9781424409228</isbn><isbn>1424409233</isbn><isbn>9781424409235</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpFkMtOwzAURM1LIi18QTf-gQTf6-u4XrCoQoFKbVm0rCs3salR85ATIfXvAVGJ1YzOSGcxjE1AZADCPKw3m9WiyFAInRFJDaAv2AgIiYRBKS9ZgkrrVEzRXP0PqK5ZAj8wlbmiWzbq-08hUEiihD2u2sodQ_PBo-u7EO3QxhOv2yG0Df-yMdjf1vPQ8OHgOD3xdTHb8u5gm6Gt79iNt8fe3Z9zzN6f59viNV2-vSyK2TININSQIhCQ8USVz52qpAKfe2mVRMR96ZEADTpl9qU2RKC0h9yVpZ-CBa2MlWM2-fMG59yui6G28bQ7fyC_AcsISyY</recordid><startdate>200710</startdate><enddate>200710</enddate><creator>Segars, W.P.</creator><creator>Mori, S.</creator><creator>Chen, G.T.Y.</creator><creator>Tsui, B.M.W.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200710</creationdate><title>Modeling respiratory motion variations in the 4D NCAT phantom</title><author>Segars, W.P. ; Mori, S. ; Chen, G.T.Y. ; Tsui, B.M.W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i105t-214149f44df6e5d351f6f3a53222bcf241292e59bc7944157f16eccf81a1759a3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Anatomy</topic><topic>Biomedical imaging</topic><topic>Computed tomography</topic><topic>Hospitals</topic><topic>Humans</topic><topic>Image segmentation</topic><topic>Imaging phantoms</topic><topic>Lungs</topic><topic>Motion analysis</topic><topic>Spline</topic><toplevel>online_resources</toplevel><creatorcontrib>Segars, W.P.</creatorcontrib><creatorcontrib>Mori, S.</creatorcontrib><creatorcontrib>Chen, G.T.Y.</creatorcontrib><creatorcontrib>Tsui, B.M.W.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Segars, W.P.</au><au>Mori, S.</au><au>Chen, G.T.Y.</au><au>Tsui, B.M.W.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Modeling respiratory motion variations in the 4D NCAT phantom</atitle><btitle>2007 IEEE Nuclear Science Symposium Conference Record</btitle><stitle>NSSMIC</stitle><date>2007-10</date><risdate>2007</risdate><volume>6</volume><spage>4531</spage><epage>4533</epage><pages>4531-4533</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>1424409225</isbn><isbn>9781424409228</isbn><eisbn>1424409233</eisbn><eisbn>9781424409235</eisbn><abstract>The current 4D NCAT phantom includes a flexible, parameterized respiratory model based on respiratory-gated CT data of a normal subject. A limitation of this model is that it is based on only one realization of the normal respiratory motion. The data upon which it was based also had a resolution lower than that offered by more advanced CT scanners and consisted of only four time frames that did not adequately cover normal tidal breathing.We further develop the 4D NCAT to more accurately model normal and abnormal states of respiration. Over two- hundred sets of 4D respiratory gated CT image data from normal and abnormal patients obtained from the Massachusetts General Hospital were used to characterize variations in the respiratory motion. Each dataset contains twenty time frames over the respiratory cycle with the patient breathing normally.With the improved resolution and better coverage of tidal breathing, this data was used to improve the respiratory model of the 4D NCAT phantom. Using automatic and semiautomatic techniques, the different respiratory structures were segmented from each time frame of each CT dataset. The time series of segmented structures were used to characterize the respiratory motion in each case. From an analysis of all normal and abnormal patient datasets, we determined the range of sizes and shapes of the right and left lungs and the range in motion (expansion in the anterior and inferior (diaphragm)directions)in the different lung regions. This analysis was used to further parameterize the general respiratory model of the 4D NCAT to more realistically model normal and abnormal variations in anatomy and in the respiratory motion. With the ability to model variations in the respiratory motion indicative of a patient population, the phantom will be a great resource to investigate the effects of respiratory motion on medical imaging and to develop compensation methods for these effects.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2007.4437117</doi><tpages>3</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2007 IEEE Nuclear Science Symposium Conference Record, 2007, Vol.6, p.4531-4533
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_4437117
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Anatomy
Biomedical imaging
Computed tomography
Hospitals
Humans
Image segmentation
Imaging phantoms
Lungs
Motion analysis
Spline
title Modeling respiratory motion variations in the 4D NCAT phantom
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T04%3A22%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Modeling%20respiratory%20motion%20variations%20in%20the%204D%20NCAT%20phantom&rft.btitle=2007%20IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record&rft.au=Segars,%20W.P.&rft.date=2007-10&rft.volume=6&rft.spage=4531&rft.epage=4533&rft.pages=4531-4533&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=1424409225&rft.isbn_list=9781424409228&rft_id=info:doi/10.1109/NSSMIC.2007.4437117&rft_dat=%3Cieee_6IE%3E4437117%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424409233&rft.eisbn_list=9781424409235&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4437117&rfr_iscdi=true