Reduction of the streak artifacts in circular cone beam CT using scanograms

We propose a method to estimate line data from scanogram in a CT scan. Combining the circle data with the estimated line data, we can reconstruct the volumetric images by use of an exact filtered backprojection or backprojection filtration algorithm for circle-line trajectories. The results show tha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Yu Zou, Zamyatin, A.A., Chiang, B.S., Silver, M.D.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3536
container_issue
container_start_page 3531
container_title
container_volume 5
creator Yu Zou
Zamyatin, A.A.
Chiang, B.S.
Silver, M.D.
description We propose a method to estimate line data from scanogram in a CT scan. Combining the circle data with the estimated line data, we can reconstruct the volumetric images by use of an exact filtered backprojection or backprojection filtration algorithm for circle-line trajectories. The results show that the streak artifacts are reduced significantly compared to that of circle-only reconstruction.
doi_str_mv 10.1109/NSSMIC.2007.4436890
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4436890</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4436890</ieee_id><sourcerecordid>4436890</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-aab602bc2ce566ba5450e3eb359d12927df171794e7604a86c693f95c0aaa8173</originalsourceid><addsrcrecordid>eNpFkM1Kw0AURsc_sK0-QTfzAql3_jNLCVqLVcHWdbmZ3tTRJpGZdOHbK1hw9cE5cBYfY1MBMyHA3zyvVk-LaiYB3ExrZUsPJ2wstNQavFTqlI2kca6AUvqzfyHNORuJX1goa_QlG-f8ASBBaT1ij6-0PYQh9h3vGz68E89DIvzkmIbYYBgyjx0PMYXDHhMPfUe8Jmx5teaHHLsdzwG7fpewzVfsosF9puvjTtjb_d26eiiWL_NFdbssonBmKBBrC7IOMpCxtkajDZCiWhm_FdJLt22EE85rchY0ljZYrxpvAiBiKZyasOlfNxLR5ivFFtP35viI-gEImFDq</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Reduction of the streak artifacts in circular cone beam CT using scanograms</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Yu Zou ; Zamyatin, A.A. ; Chiang, B.S. ; Silver, M.D.</creator><creatorcontrib>Yu Zou ; Zamyatin, A.A. ; Chiang, B.S. ; Silver, M.D.</creatorcontrib><description>We propose a method to estimate line data from scanogram in a CT scan. Combining the circle data with the estimated line data, we can reconstruct the volumetric images by use of an exact filtered backprojection or backprojection filtration algorithm for circle-line trajectories. The results show that the streak artifacts are reduced significantly compared to that of circle-only reconstruction.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 1424409225</identifier><identifier>ISBN: 9781424409228</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 1424409233</identifier><identifier>EISBN: 9781424409235</identifier><identifier>DOI: 10.1109/NSSMIC.2007.4436890</identifier><language>eng</language><publisher>IEEE</publisher><subject>Band pass filters ; Computed tomography ; Detectors ; Filtration ; Frequency ; Image reconstruction ; Interpolation ; Nuclear and plasma sciences ; Particle beams ; Silver</subject><ispartof>2007 IEEE Nuclear Science Symposium Conference Record, 2007, Vol.5, p.3531-3536</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4436890$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4436890$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Yu Zou</creatorcontrib><creatorcontrib>Zamyatin, A.A.</creatorcontrib><creatorcontrib>Chiang, B.S.</creatorcontrib><creatorcontrib>Silver, M.D.</creatorcontrib><title>Reduction of the streak artifacts in circular cone beam CT using scanograms</title><title>2007 IEEE Nuclear Science Symposium Conference Record</title><addtitle>NSSMIC</addtitle><description>We propose a method to estimate line data from scanogram in a CT scan. Combining the circle data with the estimated line data, we can reconstruct the volumetric images by use of an exact filtered backprojection or backprojection filtration algorithm for circle-line trajectories. The results show that the streak artifacts are reduced significantly compared to that of circle-only reconstruction.</description><subject>Band pass filters</subject><subject>Computed tomography</subject><subject>Detectors</subject><subject>Filtration</subject><subject>Frequency</subject><subject>Image reconstruction</subject><subject>Interpolation</subject><subject>Nuclear and plasma sciences</subject><subject>Particle beams</subject><subject>Silver</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>1424409225</isbn><isbn>9781424409228</isbn><isbn>1424409233</isbn><isbn>9781424409235</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpFkM1Kw0AURsc_sK0-QTfzAql3_jNLCVqLVcHWdbmZ3tTRJpGZdOHbK1hw9cE5cBYfY1MBMyHA3zyvVk-LaiYB3ExrZUsPJ2wstNQavFTqlI2kca6AUvqzfyHNORuJX1goa_QlG-f8ASBBaT1ij6-0PYQh9h3vGz68E89DIvzkmIbYYBgyjx0PMYXDHhMPfUe8Jmx5teaHHLsdzwG7fpewzVfsosF9puvjTtjb_d26eiiWL_NFdbssonBmKBBrC7IOMpCxtkajDZCiWhm_FdJLt22EE85rchY0ljZYrxpvAiBiKZyasOlfNxLR5ivFFtP35viI-gEImFDq</recordid><startdate>200710</startdate><enddate>200710</enddate><creator>Yu Zou</creator><creator>Zamyatin, A.A.</creator><creator>Chiang, B.S.</creator><creator>Silver, M.D.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200710</creationdate><title>Reduction of the streak artifacts in circular cone beam CT using scanograms</title><author>Yu Zou ; Zamyatin, A.A. ; Chiang, B.S. ; Silver, M.D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-aab602bc2ce566ba5450e3eb359d12927df171794e7604a86c693f95c0aaa8173</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Band pass filters</topic><topic>Computed tomography</topic><topic>Detectors</topic><topic>Filtration</topic><topic>Frequency</topic><topic>Image reconstruction</topic><topic>Interpolation</topic><topic>Nuclear and plasma sciences</topic><topic>Particle beams</topic><topic>Silver</topic><toplevel>online_resources</toplevel><creatorcontrib>Yu Zou</creatorcontrib><creatorcontrib>Zamyatin, A.A.</creatorcontrib><creatorcontrib>Chiang, B.S.</creatorcontrib><creatorcontrib>Silver, M.D.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Yu Zou</au><au>Zamyatin, A.A.</au><au>Chiang, B.S.</au><au>Silver, M.D.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Reduction of the streak artifacts in circular cone beam CT using scanograms</atitle><btitle>2007 IEEE Nuclear Science Symposium Conference Record</btitle><stitle>NSSMIC</stitle><date>2007-10</date><risdate>2007</risdate><volume>5</volume><spage>3531</spage><epage>3536</epage><pages>3531-3536</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>1424409225</isbn><isbn>9781424409228</isbn><eisbn>1424409233</eisbn><eisbn>9781424409235</eisbn><abstract>We propose a method to estimate line data from scanogram in a CT scan. Combining the circle data with the estimated line data, we can reconstruct the volumetric images by use of an exact filtered backprojection or backprojection filtration algorithm for circle-line trajectories. The results show that the streak artifacts are reduced significantly compared to that of circle-only reconstruction.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2007.4436890</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2007 IEEE Nuclear Science Symposium Conference Record, 2007, Vol.5, p.3531-3536
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_4436890
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Band pass filters
Computed tomography
Detectors
Filtration
Frequency
Image reconstruction
Interpolation
Nuclear and plasma sciences
Particle beams
Silver
title Reduction of the streak artifacts in circular cone beam CT using scanograms
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T21%3A41%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Reduction%20of%20the%20streak%20artifacts%20in%20circular%20cone%20beam%20CT%20using%20scanograms&rft.btitle=2007%20IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record&rft.au=Yu%20Zou&rft.date=2007-10&rft.volume=5&rft.spage=3531&rft.epage=3536&rft.pages=3531-3536&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=1424409225&rft.isbn_list=9781424409228&rft_id=info:doi/10.1109/NSSMIC.2007.4436890&rft_dat=%3Cieee_6IE%3E4436890%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424409233&rft.eisbn_list=9781424409235&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4436890&rfr_iscdi=true