Geometric model, control & calibration of universal benchtop CT system
A universal benchtop CT system has recently been developed and installed at GE Global Research. The system consists of a source, detector and phantom table that are mounted on a set of high accuracy motion stages. These stages permit positioning and orienting the source, detector and phantom with re...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2984 |
---|---|
container_issue | |
container_start_page | 2980 |
container_title | |
container_volume | 4 |
creator | Beque, D. Harrison, D.D. Basu, S.K. Fitzgerald, P.F. |
description | A universal benchtop CT system has recently been developed and installed at GE Global Research. The system consists of a source, detector and phantom table that are mounted on a set of high accuracy motion stages. These stages permit positioning and orienting the source, detector and phantom with respect to each other. The benchtop system is thereby able to simulate any realistic clinical CT system geometry. This work provides a geometrical model of this benchtop system and illustrates how the stages need to be controlled in order to simulate a particular CT system. This illustrates at the same time the geometrical capabilities of the system. The method and first results of the geometrical calibration of the system are also shown. |
doi_str_mv | 10.1109/NSSMIC.2007.4436760 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4436760</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4436760</ieee_id><sourcerecordid>4436760</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-2c59f3ed6571bc67e8825cbcf085c9dd0f1dfd51baae0337f03675163c8a72b33</originalsourceid><addsrcrecordid>eNpFkEtLw0AUhccX2FZ_QTezcmXinVcmWUpoa6HqonVd5nEHR5JMSaLQf2_BgqsD54MD3yFkziBnDKqnt-32dV3nHEDnUopCF3BBpkxyKaHiQlySCVdaZ1Dy6uofcHVNJuxUZqJQ8pZMh-ELgIOQckKWK0wtjn10tE0em0fqUjf2qaEP1Jkm2t6MMXU0BfrdxR_sB9NQi537HNOB1js6HIcR2ztyE0wz4P05Z-RjudjVL9nmfbWunzdZZFqNGXeqCgJ9oTSzrtBYllw56wKUylXeQ2A-eMWsMQhC6AAnS8UK4UqjuRViRuZ_uxER94c-tqY_7s9niF9L00-a</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Geometric model, control & calibration of universal benchtop CT system</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Beque, D. ; Harrison, D.D. ; Basu, S.K. ; Fitzgerald, P.F.</creator><creatorcontrib>Beque, D. ; Harrison, D.D. ; Basu, S.K. ; Fitzgerald, P.F.</creatorcontrib><description>A universal benchtop CT system has recently been developed and installed at GE Global Research. The system consists of a source, detector and phantom table that are mounted on a set of high accuracy motion stages. These stages permit positioning and orienting the source, detector and phantom with respect to each other. The benchtop system is thereby able to simulate any realistic clinical CT system geometry. This work provides a geometrical model of this benchtop system and illustrates how the stages need to be controlled in order to simulate a particular CT system. This illustrates at the same time the geometrical capabilities of the system. The method and first results of the geometrical calibration of the system are also shown.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 1424409225</identifier><identifier>ISBN: 9781424409228</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 1424409233</identifier><identifier>EISBN: 9781424409235</identifier><identifier>DOI: 10.1109/NSSMIC.2007.4436760</identifier><language>eng</language><publisher>IEEE</publisher><subject>Calibration ; Detectors ; Geometry ; Hardware ; Imaging phantoms ; Laboratories ; Motion detection ; Protocols ; Solid modeling ; Testing</subject><ispartof>2007 IEEE Nuclear Science Symposium Conference Record, 2007, Vol.4, p.2980-2984</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4436760$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27904,54898</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4436760$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Beque, D.</creatorcontrib><creatorcontrib>Harrison, D.D.</creatorcontrib><creatorcontrib>Basu, S.K.</creatorcontrib><creatorcontrib>Fitzgerald, P.F.</creatorcontrib><title>Geometric model, control & calibration of universal benchtop CT system</title><title>2007 IEEE Nuclear Science Symposium Conference Record</title><addtitle>NSSMIC</addtitle><description>A universal benchtop CT system has recently been developed and installed at GE Global Research. The system consists of a source, detector and phantom table that are mounted on a set of high accuracy motion stages. These stages permit positioning and orienting the source, detector and phantom with respect to each other. The benchtop system is thereby able to simulate any realistic clinical CT system geometry. This work provides a geometrical model of this benchtop system and illustrates how the stages need to be controlled in order to simulate a particular CT system. This illustrates at the same time the geometrical capabilities of the system. The method and first results of the geometrical calibration of the system are also shown.</description><subject>Calibration</subject><subject>Detectors</subject><subject>Geometry</subject><subject>Hardware</subject><subject>Imaging phantoms</subject><subject>Laboratories</subject><subject>Motion detection</subject><subject>Protocols</subject><subject>Solid modeling</subject><subject>Testing</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>1424409225</isbn><isbn>9781424409228</isbn><isbn>1424409233</isbn><isbn>9781424409235</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpFkEtLw0AUhccX2FZ_QTezcmXinVcmWUpoa6HqonVd5nEHR5JMSaLQf2_BgqsD54MD3yFkziBnDKqnt-32dV3nHEDnUopCF3BBpkxyKaHiQlySCVdaZ1Dy6uofcHVNJuxUZqJQ8pZMh-ELgIOQckKWK0wtjn10tE0em0fqUjf2qaEP1Jkm2t6MMXU0BfrdxR_sB9NQi537HNOB1js6HIcR2ztyE0wz4P05Z-RjudjVL9nmfbWunzdZZFqNGXeqCgJ9oTSzrtBYllw56wKUylXeQ2A-eMWsMQhC6AAnS8UK4UqjuRViRuZ_uxER94c-tqY_7s9niF9L00-a</recordid><startdate>200710</startdate><enddate>200710</enddate><creator>Beque, D.</creator><creator>Harrison, D.D.</creator><creator>Basu, S.K.</creator><creator>Fitzgerald, P.F.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200710</creationdate><title>Geometric model, control & calibration of universal benchtop CT system</title><author>Beque, D. ; Harrison, D.D. ; Basu, S.K. ; Fitzgerald, P.F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-2c59f3ed6571bc67e8825cbcf085c9dd0f1dfd51baae0337f03675163c8a72b33</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Calibration</topic><topic>Detectors</topic><topic>Geometry</topic><topic>Hardware</topic><topic>Imaging phantoms</topic><topic>Laboratories</topic><topic>Motion detection</topic><topic>Protocols</topic><topic>Solid modeling</topic><topic>Testing</topic><toplevel>online_resources</toplevel><creatorcontrib>Beque, D.</creatorcontrib><creatorcontrib>Harrison, D.D.</creatorcontrib><creatorcontrib>Basu, S.K.</creatorcontrib><creatorcontrib>Fitzgerald, P.F.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Beque, D.</au><au>Harrison, D.D.</au><au>Basu, S.K.</au><au>Fitzgerald, P.F.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Geometric model, control & calibration of universal benchtop CT system</atitle><btitle>2007 IEEE Nuclear Science Symposium Conference Record</btitle><stitle>NSSMIC</stitle><date>2007-10</date><risdate>2007</risdate><volume>4</volume><spage>2980</spage><epage>2984</epage><pages>2980-2984</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>1424409225</isbn><isbn>9781424409228</isbn><eisbn>1424409233</eisbn><eisbn>9781424409235</eisbn><abstract>A universal benchtop CT system has recently been developed and installed at GE Global Research. The system consists of a source, detector and phantom table that are mounted on a set of high accuracy motion stages. These stages permit positioning and orienting the source, detector and phantom with respect to each other. The benchtop system is thereby able to simulate any realistic clinical CT system geometry. This work provides a geometrical model of this benchtop system and illustrates how the stages need to be controlled in order to simulate a particular CT system. This illustrates at the same time the geometrical capabilities of the system. The method and first results of the geometrical calibration of the system are also shown.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2007.4436760</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1082-3654 |
ispartof | 2007 IEEE Nuclear Science Symposium Conference Record, 2007, Vol.4, p.2980-2984 |
issn | 1082-3654 2577-0829 |
language | eng |
recordid | cdi_ieee_primary_4436760 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Calibration Detectors Geometry Hardware Imaging phantoms Laboratories Motion detection Protocols Solid modeling Testing |
title | Geometric model, control & calibration of universal benchtop CT system |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T01%3A08%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Geometric%20model,%20control%20&%20calibration%20of%20universal%20benchtop%20CT%20system&rft.btitle=2007%20IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record&rft.au=Beque,%20D.&rft.date=2007-10&rft.volume=4&rft.spage=2980&rft.epage=2984&rft.pages=2980-2984&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=1424409225&rft.isbn_list=9781424409228&rft_id=info:doi/10.1109/NSSMIC.2007.4436760&rft_dat=%3Cieee_6IE%3E4436760%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424409233&rft.eisbn_list=9781424409235&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4436760&rfr_iscdi=true |