Detection of Blood Vessels in Fundus Images of the Retina using Gabor Wavelets
The monitoring of the effects of diabetes, hypertension, and premature birth on the visual system can be assisted by quantitative analysis of the vascular architecture of the retina. The application of image analysis techniques in ophthalmology becomes possible after the desired features have been d...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 6454 |
---|---|
container_issue | |
container_start_page | 6451 |
container_title | |
container_volume | 2007 |
creator | Oloumi, F. Rangayyan, R.M. Eshghzadeh-Zanjani, P. Ayres, F.J. |
description | The monitoring of the effects of diabetes, hypertension, and premature birth on the visual system can be assisted by quantitative analysis of the vascular architecture of the retina. The application of image analysis techniques in ophthalmology becomes possible after the desired features have been detected through the use of an appropriate method. We propose image processing techniques for the detection of blood vessels in the retina. The methods include the design of a bank of directionally sensitive Gabor filters for several values of the scale and elongation parameters. Forty images of the retina from the DRIVE database were used to evaluate the performance of the methods. High efficiency in the detection of blood vessels with the area under the receiver operating characteristics curve of up to 0.96 was achieved. |
doi_str_mv | 10.1109/IEMBS.2007.4353836 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>pubmed_6IE</sourceid><recordid>TN_cdi_ieee_primary_4353836</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4353836</ieee_id><sourcerecordid>18003502</sourcerecordid><originalsourceid>FETCH-LOGICAL-i338t-c4d46832a70fc8bc0772e96a0cf7d01b6c5f017d873bc74a1345d16e070e29593</originalsourceid><addsrcrecordid>eNpVkNtKAzEQhuMJW2pfQEHyAlsnm2STvbRHC1XB813JJrM1st0tza7g27vSKjg3w_B9DPw_IecMBoxBejWf3A4fBzGAGgguuebJAemnSjMRCwFKazgkXSaljkTC5NE_pvhxyyAVUaLVW4f0Q_iAdnjaYn1KOky3h4S4S-7GWKOtfVXSKqfDoqocfcEQsAjUl3TalK4JdL42Kww_Rv2O9AFrXxraBF-u6Mxk1Za-mk8ssA5n5CQ3RcD-fvfI83TyNLqJFvez-eh6EXnOdR1Z4USieWwU5FZnFpSKMU0M2Fw5YFliZQ5MuTZJZpUwjAvpWIKgAONUprxHLnd_N022RrfcbP3abL-Wv8Fa4WIneET8w_sm-TeDPV5y</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Detection of Blood Vessels in Fundus Images of the Retina using Gabor Wavelets</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Oloumi, F. ; Rangayyan, R.M. ; Eshghzadeh-Zanjani, P. ; Ayres, F.J.</creator><creatorcontrib>Oloumi, F. ; Rangayyan, R.M. ; Eshghzadeh-Zanjani, P. ; Ayres, F.J.</creatorcontrib><description>The monitoring of the effects of diabetes, hypertension, and premature birth on the visual system can be assisted by quantitative analysis of the vascular architecture of the retina. The application of image analysis techniques in ophthalmology becomes possible after the desired features have been detected through the use of an appropriate method. We propose image processing techniques for the detection of blood vessels in the retina. The methods include the design of a bank of directionally sensitive Gabor filters for several values of the scale and elongation parameters. Forty images of the retina from the DRIVE database were used to evaluate the performance of the methods. High efficiency in the detection of blood vessels with the area under the receiver operating characteristics curve of up to 0.96 was achieved.</description><identifier>ISSN: 1094-687X</identifier><identifier>ISSN: 1557-170X</identifier><identifier>ISBN: 9781424407873</identifier><identifier>ISBN: 1424407877</identifier><identifier>EISSN: 1558-4615</identifier><identifier>EISBN: 9781424407880</identifier><identifier>EISBN: 1424407885</identifier><identifier>DOI: 10.1109/IEMBS.2007.4353836</identifier><identifier>PMID: 18003502</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>Biomedical imaging ; Blood vessels ; Computer vision ; Diabetes ; Humans ; Hypertension ; Image analysis ; Image Interpretation, Computer-Assisted - methods ; Image processing ; Monitoring ; Retina ; Retinal Diseases - diagnosis ; Retinal Diseases - pathology ; Retinal Vessels - pathology ; Visual system</subject><ispartof>2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2007, Vol.2007, p.6451-6454</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4353836$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2051,27904,54899</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4353836$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18003502$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Oloumi, F.</creatorcontrib><creatorcontrib>Rangayyan, R.M.</creatorcontrib><creatorcontrib>Eshghzadeh-Zanjani, P.</creatorcontrib><creatorcontrib>Ayres, F.J.</creatorcontrib><title>Detection of Blood Vessels in Fundus Images of the Retina using Gabor Wavelets</title><title>2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><addtitle>Conf Proc IEEE Eng Med Biol Soc</addtitle><description>The monitoring of the effects of diabetes, hypertension, and premature birth on the visual system can be assisted by quantitative analysis of the vascular architecture of the retina. The application of image analysis techniques in ophthalmology becomes possible after the desired features have been detected through the use of an appropriate method. We propose image processing techniques for the detection of blood vessels in the retina. The methods include the design of a bank of directionally sensitive Gabor filters for several values of the scale and elongation parameters. Forty images of the retina from the DRIVE database were used to evaluate the performance of the methods. High efficiency in the detection of blood vessels with the area under the receiver operating characteristics curve of up to 0.96 was achieved.</description><subject>Biomedical imaging</subject><subject>Blood vessels</subject><subject>Computer vision</subject><subject>Diabetes</subject><subject>Humans</subject><subject>Hypertension</subject><subject>Image analysis</subject><subject>Image Interpretation, Computer-Assisted - methods</subject><subject>Image processing</subject><subject>Monitoring</subject><subject>Retina</subject><subject>Retinal Diseases - diagnosis</subject><subject>Retinal Diseases - pathology</subject><subject>Retinal Vessels - pathology</subject><subject>Visual system</subject><issn>1094-687X</issn><issn>1557-170X</issn><issn>1558-4615</issn><isbn>9781424407873</isbn><isbn>1424407877</isbn><isbn>9781424407880</isbn><isbn>1424407885</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><sourceid>EIF</sourceid><recordid>eNpVkNtKAzEQhuMJW2pfQEHyAlsnm2STvbRHC1XB813JJrM1st0tza7g27vSKjg3w_B9DPw_IecMBoxBejWf3A4fBzGAGgguuebJAemnSjMRCwFKazgkXSaljkTC5NE_pvhxyyAVUaLVW4f0Q_iAdnjaYn1KOky3h4S4S-7GWKOtfVXSKqfDoqocfcEQsAjUl3TalK4JdL42Kww_Rv2O9AFrXxraBF-u6Mxk1Za-mk8ssA5n5CQ3RcD-fvfI83TyNLqJFvez-eh6EXnOdR1Z4USieWwU5FZnFpSKMU0M2Fw5YFliZQ5MuTZJZpUwjAvpWIKgAONUprxHLnd_N022RrfcbP3abL-Wv8Fa4WIneET8w_sm-TeDPV5y</recordid><startdate>20070101</startdate><enddate>20070101</enddate><creator>Oloumi, F.</creator><creator>Rangayyan, R.M.</creator><creator>Eshghzadeh-Zanjani, P.</creator><creator>Ayres, F.J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope></search><sort><creationdate>20070101</creationdate><title>Detection of Blood Vessels in Fundus Images of the Retina using Gabor Wavelets</title><author>Oloumi, F. ; Rangayyan, R.M. ; Eshghzadeh-Zanjani, P. ; Ayres, F.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i338t-c4d46832a70fc8bc0772e96a0cf7d01b6c5f017d873bc74a1345d16e070e29593</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Biomedical imaging</topic><topic>Blood vessels</topic><topic>Computer vision</topic><topic>Diabetes</topic><topic>Humans</topic><topic>Hypertension</topic><topic>Image analysis</topic><topic>Image Interpretation, Computer-Assisted - methods</topic><topic>Image processing</topic><topic>Monitoring</topic><topic>Retina</topic><topic>Retinal Diseases - diagnosis</topic><topic>Retinal Diseases - pathology</topic><topic>Retinal Vessels - pathology</topic><topic>Visual system</topic><toplevel>online_resources</toplevel><creatorcontrib>Oloumi, F.</creatorcontrib><creatorcontrib>Rangayyan, R.M.</creatorcontrib><creatorcontrib>Eshghzadeh-Zanjani, P.</creatorcontrib><creatorcontrib>Ayres, F.J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Oloumi, F.</au><au>Rangayyan, R.M.</au><au>Eshghzadeh-Zanjani, P.</au><au>Ayres, F.J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Detection of Blood Vessels in Fundus Images of the Retina using Gabor Wavelets</atitle><btitle>2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</btitle><stitle>IEMBS</stitle><addtitle>Conf Proc IEEE Eng Med Biol Soc</addtitle><date>2007-01-01</date><risdate>2007</risdate><volume>2007</volume><spage>6451</spage><epage>6454</epage><pages>6451-6454</pages><issn>1094-687X</issn><issn>1557-170X</issn><eissn>1558-4615</eissn><isbn>9781424407873</isbn><isbn>1424407877</isbn><eisbn>9781424407880</eisbn><eisbn>1424407885</eisbn><abstract>The monitoring of the effects of diabetes, hypertension, and premature birth on the visual system can be assisted by quantitative analysis of the vascular architecture of the retina. The application of image analysis techniques in ophthalmology becomes possible after the desired features have been detected through the use of an appropriate method. We propose image processing techniques for the detection of blood vessels in the retina. The methods include the design of a bank of directionally sensitive Gabor filters for several values of the scale and elongation parameters. Forty images of the retina from the DRIVE database were used to evaluate the performance of the methods. High efficiency in the detection of blood vessels with the area under the receiver operating characteristics curve of up to 0.96 was achieved.</abstract><cop>United States</cop><pub>IEEE</pub><pmid>18003502</pmid><doi>10.1109/IEMBS.2007.4353836</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1094-687X |
ispartof | 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2007, Vol.2007, p.6451-6454 |
issn | 1094-687X 1557-170X 1558-4615 |
language | eng |
recordid | cdi_ieee_primary_4353836 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Biomedical imaging Blood vessels Computer vision Diabetes Humans Hypertension Image analysis Image Interpretation, Computer-Assisted - methods Image processing Monitoring Retina Retinal Diseases - diagnosis Retinal Diseases - pathology Retinal Vessels - pathology Visual system |
title | Detection of Blood Vessels in Fundus Images of the Retina using Gabor Wavelets |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T10%3A58%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Detection%20of%20Blood%20Vessels%20in%20Fundus%20Images%20of%20the%20Retina%20using%20Gabor%20Wavelets&rft.btitle=2007%2029th%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Oloumi,%20F.&rft.date=2007-01-01&rft.volume=2007&rft.spage=6451&rft.epage=6454&rft.pages=6451-6454&rft.issn=1094-687X&rft.eissn=1558-4615&rft.isbn=9781424407873&rft.isbn_list=1424407877&rft_id=info:doi/10.1109/IEMBS.2007.4353836&rft_dat=%3Cpubmed_6IE%3E18003502%3C/pubmed_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424407880&rft.eisbn_list=1424407885&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/18003502&rft_ieee_id=4353836&rfr_iscdi=true |