Z-Source Inverter Based Power Quality Compensator with Enhanced Ride-Through Capability
Distributed generation has been gaining acceptance over the years and it has the potential to provide reliable power to sensitive loads. However, distributed networks are prone to unbalanced faults conditions. This makes single inverter DG systems unsuitable as UPS systems. This paper proposes a Z-...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 962 |
---|---|
container_issue | |
container_start_page | 955 |
container_title | |
container_volume | |
creator | Gajanayake, C.J. Vilathgamuwa, D.M. Loh, P.C. Blaabjerg, F. Teodorescu, R. |
description | Distributed generation has been gaining acceptance over the years and it has the potential to provide reliable power to sensitive loads. However, distributed networks are prone to unbalanced faults conditions. This makes single inverter DG systems unsuitable as UPS systems. This paper proposes a Z- source inverter based power quality compensator and a control structure that supplies high quality voltage to the connected sensitive load in the presence of other non linear loads. The proposed topology consists of combination of shunt and series inverters connected to a common Z-source impedance network. The shunt inverter is controlled to maintain a quality voltage waveform at the load bus. Whereas the series inverter enhances the ride-through capability during grid faults, protects the shunt inverter by limiting the current and also controls the power delivered to the grid. The performance of proposed topology and controller is validated with simulation results obtained using Matlab/Simulink/PLECS. Further, it is supported with experimental results obtained using a prototype built in the laboratory. |
doi_str_mv | 10.1109/07IAS.2007.148 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4347897</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4347897</ieee_id><sourcerecordid>4347897</sourcerecordid><originalsourceid>FETCH-LOGICAL-i105t-2dc36f60f620d6eb45e22edcb0edbd0d388381c96a465907c78bf8bbeddb00e43</originalsourceid><addsrcrecordid>eNpNjEtPwkAUhcdXIiJbN276BwbvPDqPJTagJCQ-wGjckJnOrR0DLWmLhH8vRheuzkm-8x1CrhgMGQN7A3o6mg85gB4yaY7IwGrDJJeScQVwTHo81Ypq4G8n_1lq5SnpAbOacsXMOblo208AEEaxHnl9p_N62-SYTKsvbDpsklvXYkge692hP23dKnb7JKvXG6xa19VNsotdmYyr0lX5YfccA9JF2dTbjzLJ3Mb5-GNckrPCrVoc_GWfvEzGi-yezh7uptloRiODtKM85EIVCgrFISj0MkXOMeQeMPgAQRgjDMutclKlFnSujS-M9xiCB0Ap-uT69zci4nLTxLVr9ksppDZWi2_HAFaY</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Z-Source Inverter Based Power Quality Compensator with Enhanced Ride-Through Capability</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Gajanayake, C.J. ; Vilathgamuwa, D.M. ; Loh, P.C. ; Blaabjerg, F. ; Teodorescu, R.</creator><creatorcontrib>Gajanayake, C.J. ; Vilathgamuwa, D.M. ; Loh, P.C. ; Blaabjerg, F. ; Teodorescu, R.</creatorcontrib><description>Distributed generation has been gaining acceptance over the years and it has the potential to provide reliable power to sensitive loads. However, distributed networks are prone to unbalanced faults conditions. This makes single inverter DG systems unsuitable as UPS systems. This paper proposes a Z- source inverter based power quality compensator and a control structure that supplies high quality voltage to the connected sensitive load in the presence of other non linear loads. The proposed topology consists of combination of shunt and series inverters connected to a common Z-source impedance network. The shunt inverter is controlled to maintain a quality voltage waveform at the load bus. Whereas the series inverter enhances the ride-through capability during grid faults, protects the shunt inverter by limiting the current and also controls the power delivered to the grid. The performance of proposed topology and controller is validated with simulation results obtained using Matlab/Simulink/PLECS. Further, it is supported with experimental results obtained using a prototype built in the laboratory.</description><identifier>ISSN: 0197-2618</identifier><identifier>ISBN: 9781424412594</identifier><identifier>ISBN: 1424412595</identifier><identifier>EISSN: 2576-702X</identifier><identifier>EISBN: 9781424412600</identifier><identifier>EISBN: 1424412609</identifier><identifier>DOI: 10.1109/07IAS.2007.148</identifier><language>eng</language><publisher>IEEE</publisher><subject>Distributed control ; Impedance ; Inverters ; Network topology ; Power quality ; Power system reliability ; Power system stability ; Protection ; Uninterruptible power systems ; Voltage control</subject><ispartof>2007 IEEE Industry Applications Annual Meeting, 2007, p.955-962</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4347897$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4347897$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Gajanayake, C.J.</creatorcontrib><creatorcontrib>Vilathgamuwa, D.M.</creatorcontrib><creatorcontrib>Loh, P.C.</creatorcontrib><creatorcontrib>Blaabjerg, F.</creatorcontrib><creatorcontrib>Teodorescu, R.</creatorcontrib><title>Z-Source Inverter Based Power Quality Compensator with Enhanced Ride-Through Capability</title><title>2007 IEEE Industry Applications Annual Meeting</title><addtitle>IAS</addtitle><description>Distributed generation has been gaining acceptance over the years and it has the potential to provide reliable power to sensitive loads. However, distributed networks are prone to unbalanced faults conditions. This makes single inverter DG systems unsuitable as UPS systems. This paper proposes a Z- source inverter based power quality compensator and a control structure that supplies high quality voltage to the connected sensitive load in the presence of other non linear loads. The proposed topology consists of combination of shunt and series inverters connected to a common Z-source impedance network. The shunt inverter is controlled to maintain a quality voltage waveform at the load bus. Whereas the series inverter enhances the ride-through capability during grid faults, protects the shunt inverter by limiting the current and also controls the power delivered to the grid. The performance of proposed topology and controller is validated with simulation results obtained using Matlab/Simulink/PLECS. Further, it is supported with experimental results obtained using a prototype built in the laboratory.</description><subject>Distributed control</subject><subject>Impedance</subject><subject>Inverters</subject><subject>Network topology</subject><subject>Power quality</subject><subject>Power system reliability</subject><subject>Power system stability</subject><subject>Protection</subject><subject>Uninterruptible power systems</subject><subject>Voltage control</subject><issn>0197-2618</issn><issn>2576-702X</issn><isbn>9781424412594</isbn><isbn>1424412595</isbn><isbn>9781424412600</isbn><isbn>1424412609</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpNjEtPwkAUhcdXIiJbN276BwbvPDqPJTagJCQ-wGjckJnOrR0DLWmLhH8vRheuzkm-8x1CrhgMGQN7A3o6mg85gB4yaY7IwGrDJJeScQVwTHo81Ypq4G8n_1lq5SnpAbOacsXMOblo208AEEaxHnl9p_N62-SYTKsvbDpsklvXYkge692hP23dKnb7JKvXG6xa19VNsotdmYyr0lX5YfccA9JF2dTbjzLJ3Mb5-GNckrPCrVoc_GWfvEzGi-yezh7uptloRiODtKM85EIVCgrFISj0MkXOMeQeMPgAQRgjDMutclKlFnSujS-M9xiCB0Ap-uT69zci4nLTxLVr9ksppDZWi2_HAFaY</recordid><startdate>200709</startdate><enddate>200709</enddate><creator>Gajanayake, C.J.</creator><creator>Vilathgamuwa, D.M.</creator><creator>Loh, P.C.</creator><creator>Blaabjerg, F.</creator><creator>Teodorescu, R.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200709</creationdate><title>Z-Source Inverter Based Power Quality Compensator with Enhanced Ride-Through Capability</title><author>Gajanayake, C.J. ; Vilathgamuwa, D.M. ; Loh, P.C. ; Blaabjerg, F. ; Teodorescu, R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i105t-2dc36f60f620d6eb45e22edcb0edbd0d388381c96a465907c78bf8bbeddb00e43</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Distributed control</topic><topic>Impedance</topic><topic>Inverters</topic><topic>Network topology</topic><topic>Power quality</topic><topic>Power system reliability</topic><topic>Power system stability</topic><topic>Protection</topic><topic>Uninterruptible power systems</topic><topic>Voltage control</topic><toplevel>online_resources</toplevel><creatorcontrib>Gajanayake, C.J.</creatorcontrib><creatorcontrib>Vilathgamuwa, D.M.</creatorcontrib><creatorcontrib>Loh, P.C.</creatorcontrib><creatorcontrib>Blaabjerg, F.</creatorcontrib><creatorcontrib>Teodorescu, R.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Gajanayake, C.J.</au><au>Vilathgamuwa, D.M.</au><au>Loh, P.C.</au><au>Blaabjerg, F.</au><au>Teodorescu, R.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Z-Source Inverter Based Power Quality Compensator with Enhanced Ride-Through Capability</atitle><btitle>2007 IEEE Industry Applications Annual Meeting</btitle><stitle>IAS</stitle><date>2007-09</date><risdate>2007</risdate><spage>955</spage><epage>962</epage><pages>955-962</pages><issn>0197-2618</issn><eissn>2576-702X</eissn><isbn>9781424412594</isbn><isbn>1424412595</isbn><eisbn>9781424412600</eisbn><eisbn>1424412609</eisbn><abstract>Distributed generation has been gaining acceptance over the years and it has the potential to provide reliable power to sensitive loads. However, distributed networks are prone to unbalanced faults conditions. This makes single inverter DG systems unsuitable as UPS systems. This paper proposes a Z- source inverter based power quality compensator and a control structure that supplies high quality voltage to the connected sensitive load in the presence of other non linear loads. The proposed topology consists of combination of shunt and series inverters connected to a common Z-source impedance network. The shunt inverter is controlled to maintain a quality voltage waveform at the load bus. Whereas the series inverter enhances the ride-through capability during grid faults, protects the shunt inverter by limiting the current and also controls the power delivered to the grid. The performance of proposed topology and controller is validated with simulation results obtained using Matlab/Simulink/PLECS. Further, it is supported with experimental results obtained using a prototype built in the laboratory.</abstract><pub>IEEE</pub><doi>10.1109/07IAS.2007.148</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0197-2618 |
ispartof | 2007 IEEE Industry Applications Annual Meeting, 2007, p.955-962 |
issn | 0197-2618 2576-702X |
language | eng |
recordid | cdi_ieee_primary_4347897 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Distributed control Impedance Inverters Network topology Power quality Power system reliability Power system stability Protection Uninterruptible power systems Voltage control |
title | Z-Source Inverter Based Power Quality Compensator with Enhanced Ride-Through Capability |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T10%3A30%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Z-Source%20Inverter%20Based%20Power%20Quality%20Compensator%20with%20Enhanced%20Ride-Through%20Capability&rft.btitle=2007%20IEEE%20Industry%20Applications%20Annual%20Meeting&rft.au=Gajanayake,%20C.J.&rft.date=2007-09&rft.spage=955&rft.epage=962&rft.pages=955-962&rft.issn=0197-2618&rft.eissn=2576-702X&rft.isbn=9781424412594&rft.isbn_list=1424412595&rft_id=info:doi/10.1109/07IAS.2007.148&rft_dat=%3Cieee_6IE%3E4347897%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424412600&rft.eisbn_list=1424412609&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4347897&rfr_iscdi=true |