A Beta-Gamma Discriminator Circuit
The major difficulty encountered in the determination of beta-ray dose in field conditions is generally the presence of a relatively high gamma-ray component. Conventional dosimetry instruments use a shield on the detector to estimate the gamma-ray component in comparison with the beta-ray component...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on nuclear science 1985-01, Vol.32 (1), p.969-971 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 971 |
---|---|
container_issue | 1 |
container_start_page | 969 |
container_title | IEEE transactions on nuclear science |
container_volume | 32 |
creator | Erkkila, B. H. Wolf, M. A. Eisen, Y. Unruh, W. P. Brake, R. J. |
description | The major difficulty encountered in the determination of beta-ray dose in field conditions is generally the presence of a relatively high gamma-ray component. Conventional dosimetry instruments use a shield on the detector to estimate the gamma-ray component in comparison with the beta-ray component. More accurate dosimetry information can be obtained from the measured beta spectrum itself. At Los Alamos, a detector and discriminator circuit suitable for use in a portable spectrometer have been developed. This instrument will discriminate between gammas and betas in a mixed field. The portable package includes a 256-channel MCA [1] which can be programmed to give a variety of outputs, including a spectral display, and may be programmed to read dose directly. |
doi_str_mv | 10.1109/TNS.1985.4336978 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_4336978</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4336978</ieee_id><sourcerecordid>10_1109_TNS_1985_4336978</sourcerecordid><originalsourceid>FETCH-LOGICAL-c303t-2f36ff97ac3642d9b6b645a30c53335f589fb263812192fb057380428c42c99b3</originalsourceid><addsrcrecordid>eNo9j0FLAzEQRoMouFbvgpfFe7ZJJslmjnWttVD0YD2HbEwg4lpJ1oP_3i2tnj6Gb94wj5BrzhrOGc63Ty8NR6MaCaCxNSek4koZylVrTknFGDcUJeI5uSjlfRqlYqoit4v6LoyOrtwwuPo-FZ_TkD7duMt1l7L_TuMlOYvuo4SrY87I68Ny2z3SzfNq3S021AODkYoIOkZsnQctxRv2utdSOWBeAYCKymDshQbDBUcRe6ZaMEwK46XwiD3MCDvc9XlXSg7Rfk2_uPxjObN7Rzs52r2jPTpOyM0BSSGE__W_9hdKxkq8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Beta-Gamma Discriminator Circuit</title><source>IEEE Electronic Library (IEL)</source><creator>Erkkila, B. H. ; Wolf, M. A. ; Eisen, Y. ; Unruh, W. P. ; Brake, R. J.</creator><creatorcontrib>Erkkila, B. H. ; Wolf, M. A. ; Eisen, Y. ; Unruh, W. P. ; Brake, R. J.</creatorcontrib><description>The major difficulty encountered in the determination of beta-ray dose in field conditions is generally the presence of a relatively high gamma-ray component. Conventional dosimetry instruments use a shield on the detector to estimate the gamma-ray component in comparison with the beta-ray component. More accurate dosimetry information can be obtained from the measured beta spectrum itself. At Los Alamos, a detector and discriminator circuit suitable for use in a portable spectrometer have been developed. This instrument will discriminate between gammas and betas in a mixed field. The portable package includes a 256-channel MCA [1] which can be programmed to give a variety of outputs, including a spectral display, and may be programmed to read dose directly.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.1985.4336978</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>IEEE</publisher><subject>Circuits ; Displays ; Dosimetry ; Gamma ray detection ; Gamma ray detectors ; Instruments ; Laboratories ; Packaging ; Pulse amplifiers ; Spectroscopy</subject><ispartof>IEEE transactions on nuclear science, 1985-01, Vol.32 (1), p.969-971</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c303t-2f36ff97ac3642d9b6b645a30c53335f589fb263812192fb057380428c42c99b3</citedby><cites>FETCH-LOGICAL-c303t-2f36ff97ac3642d9b6b645a30c53335f589fb263812192fb057380428c42c99b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4336978$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,778,782,794,27907,27908,54741</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4336978$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Erkkila, B. H.</creatorcontrib><creatorcontrib>Wolf, M. A.</creatorcontrib><creatorcontrib>Eisen, Y.</creatorcontrib><creatorcontrib>Unruh, W. P.</creatorcontrib><creatorcontrib>Brake, R. J.</creatorcontrib><title>A Beta-Gamma Discriminator Circuit</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>The major difficulty encountered in the determination of beta-ray dose in field conditions is generally the presence of a relatively high gamma-ray component. Conventional dosimetry instruments use a shield on the detector to estimate the gamma-ray component in comparison with the beta-ray component. More accurate dosimetry information can be obtained from the measured beta spectrum itself. At Los Alamos, a detector and discriminator circuit suitable for use in a portable spectrometer have been developed. This instrument will discriminate between gammas and betas in a mixed field. The portable package includes a 256-channel MCA [1] which can be programmed to give a variety of outputs, including a spectral display, and may be programmed to read dose directly.</description><subject>Circuits</subject><subject>Displays</subject><subject>Dosimetry</subject><subject>Gamma ray detection</subject><subject>Gamma ray detectors</subject><subject>Instruments</subject><subject>Laboratories</subject><subject>Packaging</subject><subject>Pulse amplifiers</subject><subject>Spectroscopy</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1985</creationdate><recordtype>article</recordtype><recordid>eNo9j0FLAzEQRoMouFbvgpfFe7ZJJslmjnWttVD0YD2HbEwg4lpJ1oP_3i2tnj6Gb94wj5BrzhrOGc63Ty8NR6MaCaCxNSek4koZylVrTknFGDcUJeI5uSjlfRqlYqoit4v6LoyOrtwwuPo-FZ_TkD7duMt1l7L_TuMlOYvuo4SrY87I68Ny2z3SzfNq3S021AODkYoIOkZsnQctxRv2utdSOWBeAYCKymDshQbDBUcRe6ZaMEwK46XwiD3MCDvc9XlXSg7Rfk2_uPxjObN7Rzs52r2jPTpOyM0BSSGE__W_9hdKxkq8</recordid><startdate>19850101</startdate><enddate>19850101</enddate><creator>Erkkila, B. H.</creator><creator>Wolf, M. A.</creator><creator>Eisen, Y.</creator><creator>Unruh, W. P.</creator><creator>Brake, R. J.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19850101</creationdate><title>A Beta-Gamma Discriminator Circuit</title><author>Erkkila, B. H. ; Wolf, M. A. ; Eisen, Y. ; Unruh, W. P. ; Brake, R. J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c303t-2f36ff97ac3642d9b6b645a30c53335f589fb263812192fb057380428c42c99b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1985</creationdate><topic>Circuits</topic><topic>Displays</topic><topic>Dosimetry</topic><topic>Gamma ray detection</topic><topic>Gamma ray detectors</topic><topic>Instruments</topic><topic>Laboratories</topic><topic>Packaging</topic><topic>Pulse amplifiers</topic><topic>Spectroscopy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Erkkila, B. H.</creatorcontrib><creatorcontrib>Wolf, M. A.</creatorcontrib><creatorcontrib>Eisen, Y.</creatorcontrib><creatorcontrib>Unruh, W. P.</creatorcontrib><creatorcontrib>Brake, R. J.</creatorcontrib><collection>CrossRef</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Erkkila, B. H.</au><au>Wolf, M. A.</au><au>Eisen, Y.</au><au>Unruh, W. P.</au><au>Brake, R. J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Beta-Gamma Discriminator Circuit</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>1985-01-01</date><risdate>1985</risdate><volume>32</volume><issue>1</issue><spage>969</spage><epage>971</epage><pages>969-971</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>The major difficulty encountered in the determination of beta-ray dose in field conditions is generally the presence of a relatively high gamma-ray component. Conventional dosimetry instruments use a shield on the detector to estimate the gamma-ray component in comparison with the beta-ray component. More accurate dosimetry information can be obtained from the measured beta spectrum itself. At Los Alamos, a detector and discriminator circuit suitable for use in a portable spectrometer have been developed. This instrument will discriminate between gammas and betas in a mixed field. The portable package includes a 256-channel MCA [1] which can be programmed to give a variety of outputs, including a spectral display, and may be programmed to read dose directly.</abstract><pub>IEEE</pub><doi>10.1109/TNS.1985.4336978</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9499 |
ispartof | IEEE transactions on nuclear science, 1985-01, Vol.32 (1), p.969-971 |
issn | 0018-9499 1558-1578 |
language | eng |
recordid | cdi_ieee_primary_4336978 |
source | IEEE Electronic Library (IEL) |
subjects | Circuits Displays Dosimetry Gamma ray detection Gamma ray detectors Instruments Laboratories Packaging Pulse amplifiers Spectroscopy |
title | A Beta-Gamma Discriminator Circuit |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T06%3A55%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Beta-Gamma%20Discriminator%20Circuit&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Erkkila,%20B.%20H.&rft.date=1985-01-01&rft.volume=32&rft.issue=1&rft.spage=969&rft.epage=971&rft.pages=969-971&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.1985.4336978&rft_dat=%3Ccrossref_RIE%3E10_1109_TNS_1985_4336978%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4336978&rfr_iscdi=true |