Nondestructive Assay of Fissile Material Samples in Support of Nuclear Safeguards
Samples of fissile material can be assayed by bombarding with 300-to 600-keV neutrons and counting delayed neutrons from fission. Interrogating neutron energy selection is based upon considerations of sample penetrability and insensitivity of response to nonfissile isotopes. Significant cost savings...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on nuclear science 1974-01, Vol.21 (1), p.628-632 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 632 |
---|---|
container_issue | 1 |
container_start_page | 628 |
container_title | IEEE transactions on nuclear science |
container_volume | 21 |
creator | Evans, Albert E. |
description | Samples of fissile material can be assayed by bombarding with 300-to 600-keV neutrons and counting delayed neutrons from fission. Interrogating neutron energy selection is based upon considerations of sample penetrability and insensitivity of response to nonfissile isotopes. Significant cost savings in nuclear safeguards and quality control are possible. |
doi_str_mv | 10.1109/TNS.1974.4327524 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_4327524</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4327524</ieee_id><sourcerecordid>10_1109_TNS_1974_4327524</sourcerecordid><originalsourceid>FETCH-LOGICAL-c305t-a8ffced11baebf28482bd123636e8679fa88b886ff214d0fc319819b9f2ba3313</originalsourceid><addsrcrecordid>eNo9kF1LwzAYhYMoOKf3gjf5A61589Eml2M4FeZENq9L2r6RSLeWpBX2723Z9OpwOB8XDyH3wFIAZh53m20KJpepFDxXXF6QGSilE1C5viQzxkAnRhpzTW5i_B6tVEzNyMemPdQY-zBUvf9BuojRHmnr6MrH6Bukb7bH4G1Dt3bfNRipP9Dt0HVt6KfaZqgatGFMHX4NNtTxllw520S8O-ucfK6edsuXZP3-_LpcrJNKMNUnVjtXYQ1QWiwd11LzsgYuMpGhznLjrNal1plzHGTNXCXAaDClcby0QoCYE3b6rUIbY0BXdMHvbTgWwIoJSTEiKSYkxRnJOHk4TTwi_tf_0l9ThV4p</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Nondestructive Assay of Fissile Material Samples in Support of Nuclear Safeguards</title><source>IEEE Electronic Library (IEL)</source><creator>Evans, Albert E.</creator><creatorcontrib>Evans, Albert E.</creatorcontrib><description>Samples of fissile material can be assayed by bombarding with 300-to 600-keV neutrons and counting delayed neutrons from fission. Interrogating neutron energy selection is based upon considerations of sample penetrability and insensitivity of response to nonfissile isotopes. Significant cost savings in nuclear safeguards and quality control are possible.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.1974.4327524</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>IEEE</publisher><subject>Chemical analysis ; Costs ; Delay effects ; Fuels ; Isotopes ; Laboratories ; Material storage ; Neutrons ; Nuclear measurements ; Quality control</subject><ispartof>IEEE transactions on nuclear science, 1974-01, Vol.21 (1), p.628-632</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c305t-a8ffced11baebf28482bd123636e8679fa88b886ff214d0fc319819b9f2ba3313</citedby><cites>FETCH-LOGICAL-c305t-a8ffced11baebf28482bd123636e8679fa88b886ff214d0fc319819b9f2ba3313</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4327524$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27922,27923,54756</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4327524$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Evans, Albert E.</creatorcontrib><title>Nondestructive Assay of Fissile Material Samples in Support of Nuclear Safeguards</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>Samples of fissile material can be assayed by bombarding with 300-to 600-keV neutrons and counting delayed neutrons from fission. Interrogating neutron energy selection is based upon considerations of sample penetrability and insensitivity of response to nonfissile isotopes. Significant cost savings in nuclear safeguards and quality control are possible.</description><subject>Chemical analysis</subject><subject>Costs</subject><subject>Delay effects</subject><subject>Fuels</subject><subject>Isotopes</subject><subject>Laboratories</subject><subject>Material storage</subject><subject>Neutrons</subject><subject>Nuclear measurements</subject><subject>Quality control</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1974</creationdate><recordtype>article</recordtype><recordid>eNo9kF1LwzAYhYMoOKf3gjf5A61589Eml2M4FeZENq9L2r6RSLeWpBX2723Z9OpwOB8XDyH3wFIAZh53m20KJpepFDxXXF6QGSilE1C5viQzxkAnRhpzTW5i_B6tVEzNyMemPdQY-zBUvf9BuojRHmnr6MrH6Bukb7bH4G1Dt3bfNRipP9Dt0HVt6KfaZqgatGFMHX4NNtTxllw520S8O-ucfK6edsuXZP3-_LpcrJNKMNUnVjtXYQ1QWiwd11LzsgYuMpGhznLjrNal1plzHGTNXCXAaDClcby0QoCYE3b6rUIbY0BXdMHvbTgWwIoJSTEiKSYkxRnJOHk4TTwi_tf_0l9ThV4p</recordid><startdate>19740101</startdate><enddate>19740101</enddate><creator>Evans, Albert E.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19740101</creationdate><title>Nondestructive Assay of Fissile Material Samples in Support of Nuclear Safeguards</title><author>Evans, Albert E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c305t-a8ffced11baebf28482bd123636e8679fa88b886ff214d0fc319819b9f2ba3313</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1974</creationdate><topic>Chemical analysis</topic><topic>Costs</topic><topic>Delay effects</topic><topic>Fuels</topic><topic>Isotopes</topic><topic>Laboratories</topic><topic>Material storage</topic><topic>Neutrons</topic><topic>Nuclear measurements</topic><topic>Quality control</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Evans, Albert E.</creatorcontrib><collection>CrossRef</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Evans, Albert E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Nondestructive Assay of Fissile Material Samples in Support of Nuclear Safeguards</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>1974-01-01</date><risdate>1974</risdate><volume>21</volume><issue>1</issue><spage>628</spage><epage>632</epage><pages>628-632</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>Samples of fissile material can be assayed by bombarding with 300-to 600-keV neutrons and counting delayed neutrons from fission. Interrogating neutron energy selection is based upon considerations of sample penetrability and insensitivity of response to nonfissile isotopes. Significant cost savings in nuclear safeguards and quality control are possible.</abstract><pub>IEEE</pub><doi>10.1109/TNS.1974.4327524</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9499 |
ispartof | IEEE transactions on nuclear science, 1974-01, Vol.21 (1), p.628-632 |
issn | 0018-9499 1558-1578 |
language | eng |
recordid | cdi_ieee_primary_4327524 |
source | IEEE Electronic Library (IEL) |
subjects | Chemical analysis Costs Delay effects Fuels Isotopes Laboratories Material storage Neutrons Nuclear measurements Quality control |
title | Nondestructive Assay of Fissile Material Samples in Support of Nuclear Safeguards |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T20%3A42%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Nondestructive%20Assay%20of%20Fissile%20Material%20Samples%20in%20Support%20of%20Nuclear%20Safeguards&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Evans,%20Albert%20E.&rft.date=1974-01-01&rft.volume=21&rft.issue=1&rft.spage=628&rft.epage=632&rft.pages=628-632&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.1974.4327524&rft_dat=%3Ccrossref_RIE%3E10_1109_TNS_1974_4327524%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4327524&rfr_iscdi=true |