Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review

Coaxial line reflection methods for measuring dielectric properties of biological materials at radio (RF) and microwave (MF) frequencies are reviewed and compared from the point of view of their relative uncertainties of measurement of lossy substances with high dielectric constant. Advantages and l...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on instrumentation and measurement 1980-01, Vol.29 (3), p.176-183
Hauptverfasser: Stuchly, Maria A., Stuchly, Stanislaw S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 183
container_issue 3
container_start_page 176
container_title IEEE transactions on instrumentation and measurement
container_volume 29
creator Stuchly, Maria A.
Stuchly, Stanislaw S.
description Coaxial line reflection methods for measuring dielectric properties of biological materials at radio (RF) and microwave (MF) frequencies are reviewed and compared from the point of view of their relative uncertainties of measurement of lossy substances with high dielectric constant. Advantages and limitations of different methods and some practical recommendations are presented.
doi_str_mv 10.1109/TIM.1980.4314902
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_4314902</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4314902</ieee_id><sourcerecordid>10_1109_TIM_1980_4314902</sourcerecordid><originalsourceid>FETCH-LOGICAL-c374t-be33edcfda3817b0bbb97dd03e3f510501e3165c3bee1f324c0e1bc922e2b9063</originalsourceid><addsrcrecordid>eNo9kM1OAjEQxxujiYjeTbz0BRan2_2gR0RREogG8bxpu1OsWbfaLqBv4GNbAnqaSf4fM_kRcslgwBiI6-V0PmBiCIOMs0xAekR6LM_LRBRFekx6AGyYiCwvTslZCG8AUBZZ2SM_Yye_rGzozLZIF2ga1J11LZ1j9-rqQI3zcZdh7W27orcWdwZvNX3y7gN9ZzFQZ-iNdY1bWR2bntcqdLLVUZAdXcjaOirbms6t9m4rN0gnHj_X2OqYTUbx6Mbi9pycGNkEvDjMPnmZ3C3HD8ns8X46Hs0SzcusSxRyjrU2teRDVipQSomyroEjNzmDHBhyVuSaK0RmeJppQKa0SFNMlYCC9wnse-MzIXg01Ye379J_VwyqHckqkqx2JKsDyRi52kcsIv7b_9RfGhhyTg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review</title><source>IEEE Electronic Library (IEL)</source><creator>Stuchly, Maria A. ; Stuchly, Stanislaw S.</creator><creatorcontrib>Stuchly, Maria A. ; Stuchly, Stanislaw S.</creatorcontrib><description>Coaxial line reflection methods for measuring dielectric properties of biological materials at radio (RF) and microwave (MF) frequencies are reviewed and compared from the point of view of their relative uncertainties of measurement of lossy substances with high dielectric constant. Advantages and limitations of different methods and some practical recommendations are presented.</description><identifier>ISSN: 0018-9456</identifier><identifier>EISSN: 1557-9662</identifier><identifier>DOI: 10.1109/TIM.1980.4314902</identifier><identifier>CODEN: IEIMAO</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biological materials ; Coaxial components ; Dielectric loss measurement ; Dielectric losses ; Dielectric measurements ; Frequency measurement ; Loss measurement ; Microwave measurements ; Microwave theory and techniques ; Reflection</subject><ispartof>IEEE transactions on instrumentation and measurement, 1980-01, Vol.29 (3), p.176-183</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c374t-be33edcfda3817b0bbb97dd03e3f510501e3165c3bee1f324c0e1bc922e2b9063</citedby><cites>FETCH-LOGICAL-c374t-be33edcfda3817b0bbb97dd03e3f510501e3165c3bee1f324c0e1bc922e2b9063</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4314902$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4314902$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Stuchly, Maria A.</creatorcontrib><creatorcontrib>Stuchly, Stanislaw S.</creatorcontrib><title>Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review</title><title>IEEE transactions on instrumentation and measurement</title><addtitle>TIM</addtitle><description>Coaxial line reflection methods for measuring dielectric properties of biological materials at radio (RF) and microwave (MF) frequencies are reviewed and compared from the point of view of their relative uncertainties of measurement of lossy substances with high dielectric constant. Advantages and limitations of different methods and some practical recommendations are presented.</description><subject>Biological materials</subject><subject>Coaxial components</subject><subject>Dielectric loss measurement</subject><subject>Dielectric losses</subject><subject>Dielectric measurements</subject><subject>Frequency measurement</subject><subject>Loss measurement</subject><subject>Microwave measurements</subject><subject>Microwave theory and techniques</subject><subject>Reflection</subject><issn>0018-9456</issn><issn>1557-9662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1980</creationdate><recordtype>article</recordtype><recordid>eNo9kM1OAjEQxxujiYjeTbz0BRan2_2gR0RREogG8bxpu1OsWbfaLqBv4GNbAnqaSf4fM_kRcslgwBiI6-V0PmBiCIOMs0xAekR6LM_LRBRFekx6AGyYiCwvTslZCG8AUBZZ2SM_Yye_rGzozLZIF2ga1J11LZ1j9-rqQI3zcZdh7W27orcWdwZvNX3y7gN9ZzFQZ-iNdY1bWR2bntcqdLLVUZAdXcjaOirbms6t9m4rN0gnHj_X2OqYTUbx6Mbi9pycGNkEvDjMPnmZ3C3HD8ns8X46Hs0SzcusSxRyjrU2teRDVipQSomyroEjNzmDHBhyVuSaK0RmeJppQKa0SFNMlYCC9wnse-MzIXg01Ye379J_VwyqHckqkqx2JKsDyRi52kcsIv7b_9RfGhhyTg</recordid><startdate>19800101</startdate><enddate>19800101</enddate><creator>Stuchly, Maria A.</creator><creator>Stuchly, Stanislaw S.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19800101</creationdate><title>Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review</title><author>Stuchly, Maria A. ; Stuchly, Stanislaw S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c374t-be33edcfda3817b0bbb97dd03e3f510501e3165c3bee1f324c0e1bc922e2b9063</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1980</creationdate><topic>Biological materials</topic><topic>Coaxial components</topic><topic>Dielectric loss measurement</topic><topic>Dielectric losses</topic><topic>Dielectric measurements</topic><topic>Frequency measurement</topic><topic>Loss measurement</topic><topic>Microwave measurements</topic><topic>Microwave theory and techniques</topic><topic>Reflection</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stuchly, Maria A.</creatorcontrib><creatorcontrib>Stuchly, Stanislaw S.</creatorcontrib><collection>CrossRef</collection><jtitle>IEEE transactions on instrumentation and measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Stuchly, Maria A.</au><au>Stuchly, Stanislaw S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review</atitle><jtitle>IEEE transactions on instrumentation and measurement</jtitle><stitle>TIM</stitle><date>1980-01-01</date><risdate>1980</risdate><volume>29</volume><issue>3</issue><spage>176</spage><epage>183</epage><pages>176-183</pages><issn>0018-9456</issn><eissn>1557-9662</eissn><coden>IEIMAO</coden><abstract>Coaxial line reflection methods for measuring dielectric properties of biological materials at radio (RF) and microwave (MF) frequencies are reviewed and compared from the point of view of their relative uncertainties of measurement of lossy substances with high dielectric constant. Advantages and limitations of different methods and some practical recommendations are presented.</abstract><pub>IEEE</pub><doi>10.1109/TIM.1980.4314902</doi><tpages>8</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9456
ispartof IEEE transactions on instrumentation and measurement, 1980-01, Vol.29 (3), p.176-183
issn 0018-9456
1557-9662
language eng
recordid cdi_ieee_primary_4314902
source IEEE Electronic Library (IEL)
subjects Biological materials
Coaxial components
Dielectric loss measurement
Dielectric losses
Dielectric measurements
Frequency measurement
Loss measurement
Microwave measurements
Microwave theory and techniques
Reflection
title Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T17%3A50%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Coaxial%20Line%20Reflection%20Methods%20for%20Measuring%20Dielectric%20Properties%20of%20Biological%20Substances%20at%20Radio%20and%20Microwave%20Frequencies-A%20Review&rft.jtitle=IEEE%20transactions%20on%20instrumentation%20and%20measurement&rft.au=Stuchly,%20Maria%20A.&rft.date=1980-01-01&rft.volume=29&rft.issue=3&rft.spage=176&rft.epage=183&rft.pages=176-183&rft.issn=0018-9456&rft.eissn=1557-9662&rft.coden=IEIMAO&rft_id=info:doi/10.1109/TIM.1980.4314902&rft_dat=%3Ccrossref_RIE%3E10_1109_TIM_1980_4314902%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4314902&rfr_iscdi=true