A Novel Telemedicine System for Monitoring Congestive Heart Failure Patients

Summary form only given. The aim of this project was to build a portable system designed to monitor on a daily basis the severity of pulmonary edema in chronic heart failure (CHF) patients. As for today, the current methods for monitoring pulmonary edema severity in these patients are inaccurate (we...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Radai, M.M., Krief, H., Engelman, T., Abboud, S.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 45
container_issue
container_start_page 45
container_title
container_volume
creator Radai, M.M.
Krief, H.
Engelman, T.
Abboud, S.
description Summary form only given. The aim of this project was to build a portable system designed to monitor on a daily basis the severity of pulmonary edema in chronic heart failure (CHF) patients. As for today, the current methods for monitoring pulmonary edema severity in these patients are inaccurate (weighing), or involve ionizing radiation (CT imaging). The proposed system is based on the principles of bio-impedance - a non invasive technique which retrieves information regarding the electrical characteristics of internal tissues by applying small amplitude currents into the body, and measuring the developed electrical potentials.
doi_str_mv 10.1109/ITRE.2006.381530
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4266291</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4266291</ieee_id><sourcerecordid>4266291</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-fd622d57bf1519d658bd7891ee17719a2ed19f72c1719c0d0901b7860a0819093</originalsourceid><addsrcrecordid>eNo1jF1LwzAUQCMiqLPvgi_5A633pk2TPI6yuUH9QCv4NtLmdkT6IW0c7N87UM_L4bwcxm4REkQw99vqdZUIgDxJNcoUzlhklMZMZBloadQ5u_4P_XHJonn-hBOpkaiyK1Yu-dN4oI5X1FFPzjd-IP52nAP1vB0n_jgOPoyTH_a8GIc9zcEfiG_IToGvre--J-IvNngawnzDLlrbzRT9ecHe16uq2MTl88O2WJaxRyVD3LpcCCdV3aJE43Kpa6e0QSJUCo0V5NC0SjR4qgYcGMBa6RwsaDRg0gW7-_16Itp9Tb6303GXiTwXBtMfjnJNpw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A Novel Telemedicine System for Monitoring Congestive Heart Failure Patients</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Radai, M.M. ; Krief, H. ; Engelman, T. ; Abboud, S.</creator><creatorcontrib>Radai, M.M. ; Krief, H. ; Engelman, T. ; Abboud, S.</creatorcontrib><description>Summary form only given. The aim of this project was to build a portable system designed to monitor on a daily basis the severity of pulmonary edema in chronic heart failure (CHF) patients. As for today, the current methods for monitoring pulmonary edema severity in these patients are inaccurate (weighing), or involve ionizing radiation (CT imaging). The proposed system is based on the principles of bio-impedance - a non invasive technique which retrieves information regarding the electrical characteristics of internal tissues by applying small amplitude currents into the body, and measuring the developed electrical potentials.</description><identifier>ISBN: 142440858X</identifier><identifier>ISBN: 9781424408580</identifier><identifier>EISBN: 9781424408597</identifier><identifier>EISBN: 1424408598</identifier><identifier>DOI: 10.1109/ITRE.2006.381530</identifier><language>eng</language><publisher>IEEE</publisher><subject>Computed tomography ; Condition monitoring ; Current measurement ; Electric variables ; Heart ; Information retrieval ; Ionizing radiation ; Patient monitoring ; Radiation monitoring ; Telemedicine</subject><ispartof>2006 International Conference on Information Technology: Research and Education, 2006, p.45-45</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4266291$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,777,781,786,787,2052,27906,54901</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4266291$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Radai, M.M.</creatorcontrib><creatorcontrib>Krief, H.</creatorcontrib><creatorcontrib>Engelman, T.</creatorcontrib><creatorcontrib>Abboud, S.</creatorcontrib><title>A Novel Telemedicine System for Monitoring Congestive Heart Failure Patients</title><title>2006 International Conference on Information Technology: Research and Education</title><addtitle>ITRE</addtitle><description>Summary form only given. The aim of this project was to build a portable system designed to monitor on a daily basis the severity of pulmonary edema in chronic heart failure (CHF) patients. As for today, the current methods for monitoring pulmonary edema severity in these patients are inaccurate (weighing), or involve ionizing radiation (CT imaging). The proposed system is based on the principles of bio-impedance - a non invasive technique which retrieves information regarding the electrical characteristics of internal tissues by applying small amplitude currents into the body, and measuring the developed electrical potentials.</description><subject>Computed tomography</subject><subject>Condition monitoring</subject><subject>Current measurement</subject><subject>Electric variables</subject><subject>Heart</subject><subject>Information retrieval</subject><subject>Ionizing radiation</subject><subject>Patient monitoring</subject><subject>Radiation monitoring</subject><subject>Telemedicine</subject><isbn>142440858X</isbn><isbn>9781424408580</isbn><isbn>9781424408597</isbn><isbn>1424408598</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2006</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1jF1LwzAUQCMiqLPvgi_5A633pk2TPI6yuUH9QCv4NtLmdkT6IW0c7N87UM_L4bwcxm4REkQw99vqdZUIgDxJNcoUzlhklMZMZBloadQ5u_4P_XHJonn-hBOpkaiyK1Yu-dN4oI5X1FFPzjd-IP52nAP1vB0n_jgOPoyTH_a8GIc9zcEfiG_IToGvre--J-IvNngawnzDLlrbzRT9ecHe16uq2MTl88O2WJaxRyVD3LpcCCdV3aJE43Kpa6e0QSJUCo0V5NC0SjR4qgYcGMBa6RwsaDRg0gW7-_16Itp9Tb6303GXiTwXBtMfjnJNpw</recordid><startdate>200610</startdate><enddate>200610</enddate><creator>Radai, M.M.</creator><creator>Krief, H.</creator><creator>Engelman, T.</creator><creator>Abboud, S.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200610</creationdate><title>A Novel Telemedicine System for Monitoring Congestive Heart Failure Patients</title><author>Radai, M.M. ; Krief, H. ; Engelman, T. ; Abboud, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-fd622d57bf1519d658bd7891ee17719a2ed19f72c1719c0d0901b7860a0819093</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Computed tomography</topic><topic>Condition monitoring</topic><topic>Current measurement</topic><topic>Electric variables</topic><topic>Heart</topic><topic>Information retrieval</topic><topic>Ionizing radiation</topic><topic>Patient monitoring</topic><topic>Radiation monitoring</topic><topic>Telemedicine</topic><toplevel>online_resources</toplevel><creatorcontrib>Radai, M.M.</creatorcontrib><creatorcontrib>Krief, H.</creatorcontrib><creatorcontrib>Engelman, T.</creatorcontrib><creatorcontrib>Abboud, S.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Radai, M.M.</au><au>Krief, H.</au><au>Engelman, T.</au><au>Abboud, S.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A Novel Telemedicine System for Monitoring Congestive Heart Failure Patients</atitle><btitle>2006 International Conference on Information Technology: Research and Education</btitle><stitle>ITRE</stitle><date>2006-10</date><risdate>2006</risdate><spage>45</spage><epage>45</epage><pages>45-45</pages><isbn>142440858X</isbn><isbn>9781424408580</isbn><eisbn>9781424408597</eisbn><eisbn>1424408598</eisbn><abstract>Summary form only given. The aim of this project was to build a portable system designed to monitor on a daily basis the severity of pulmonary edema in chronic heart failure (CHF) patients. As for today, the current methods for monitoring pulmonary edema severity in these patients are inaccurate (weighing), or involve ionizing radiation (CT imaging). The proposed system is based on the principles of bio-impedance - a non invasive technique which retrieves information regarding the electrical characteristics of internal tissues by applying small amplitude currents into the body, and measuring the developed electrical potentials.</abstract><pub>IEEE</pub><doi>10.1109/ITRE.2006.381530</doi><tpages>1</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 142440858X
ispartof 2006 International Conference on Information Technology: Research and Education, 2006, p.45-45
issn
language eng
recordid cdi_ieee_primary_4266291
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Computed tomography
Condition monitoring
Current measurement
Electric variables
Heart
Information retrieval
Ionizing radiation
Patient monitoring
Radiation monitoring
Telemedicine
title A Novel Telemedicine System for Monitoring Congestive Heart Failure Patients
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T14%3A01%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20Novel%20Telemedicine%20System%20for%20Monitoring%20Congestive%20Heart%20Failure%20Patients&rft.btitle=2006%20International%20Conference%20on%20Information%20Technology:%20Research%20and%20Education&rft.au=Radai,%20M.M.&rft.date=2006-10&rft.spage=45&rft.epage=45&rft.pages=45-45&rft.isbn=142440858X&rft.isbn_list=9781424408580&rft_id=info:doi/10.1109/ITRE.2006.381530&rft_dat=%3Cieee_6IE%3E4266291%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424408597&rft.eisbn_list=1424408598&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4266291&rfr_iscdi=true