Optimal monitoring and management of a water storage with pollution constraints

The aim is to fill water storage with potable water of a given quality, for subsequent treatment and distribution to a water conveying system. During a given period, a set of several pumping stations is working to deliver water from different sources at different locations. A multi-stage control pro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ioslovich, I., Gutman, P.-O.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 6
container_issue
container_start_page 1
container_title
container_volume
creator Ioslovich, I.
Gutman, P.-O.
description The aim is to fill water storage with potable water of a given quality, for subsequent treatment and distribution to a water conveying system. During a given period, a set of several pumping stations is working to deliver water from different sources at different locations. A multi-stage control process is considered whereby the total pumping time is divided into short sampling intervals. The intensity of pumping as a function of time is the control variable. It is assumed that there exists a reliable forecast of every pollutant as a function of time and water source. The amount of the pollutants is constrained in the final mass of water in the storage. The mass of water at the end of the operation period should be maximized
doi_str_mv 10.1109/MED.2006.328851
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4124957</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4124957</ieee_id><sourcerecordid>4124957</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-c410fed581dad3d851d2fc21c9ba749df0ef4fdc4c08c2bab75e1c07e25d84493</originalsourceid><addsrcrecordid>eNo1T81KxDAYjIigrj178JIX6PolTZvkKOu6Ciu97H1J87NG2qQ0kcW3N6AehmGGYZhB6J7AmhCQj-_b5zUF6NYNFaIlF6iSXEBBx4vdXKLbf0HINapS-gQAIjvOgN2gvp-zn9SIpxh8josPJ6yCwZMK6mQnGzKODit8VtkuOJVEsfHZ5w88x3H8yj4GrGNIeVE-5HSHrpwak63-eIUOL9vD5rXe97u3zdO-9hJyrRkBZ00riFGmMWW2oU5TouWgOJPGgXXMGc00CE0HNfDWEg3c0tYIxmSzQg-_td5ae5yXcmH5PjJCmWx58wP8uVEP</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Optimal monitoring and management of a water storage with pollution constraints</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ioslovich, I. ; Gutman, P.-O.</creator><creatorcontrib>Ioslovich, I. ; Gutman, P.-O.</creatorcontrib><description>The aim is to fill water storage with potable water of a given quality, for subsequent treatment and distribution to a water conveying system. During a given period, a set of several pumping stations is working to deliver water from different sources at different locations. A multi-stage control process is considered whereby the total pumping time is divided into short sampling intervals. The intensity of pumping as a function of time is the control variable. It is assumed that there exists a reliable forecast of every pollutant as a function of time and water source. The amount of the pollutants is constrained in the final mass of water in the storage. The mass of water at the end of the operation period should be maximized</description><identifier>ISBN: 0978672011</identifier><identifier>ISBN: 9780978672010</identifier><identifier>EISBN: 9780978672003</identifier><identifier>EISBN: 0978672003</identifier><identifier>DOI: 10.1109/MED.2006.328851</identifier><language>eng</language><publisher>IEEE</publisher><subject>Decision support systems ; Effluents ; Environmentally friendly manufacturing techniques ; Industrial pollution ; Monitoring ; Quality management ; Sampling methods ; Water pollution ; Water resources ; Water storage</subject><ispartof>2006 14th Mediterranean Conference on Control and Automation, 2006, p.1-6</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4124957$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4124957$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ioslovich, I.</creatorcontrib><creatorcontrib>Gutman, P.-O.</creatorcontrib><title>Optimal monitoring and management of a water storage with pollution constraints</title><title>2006 14th Mediterranean Conference on Control and Automation</title><addtitle>MED</addtitle><description>The aim is to fill water storage with potable water of a given quality, for subsequent treatment and distribution to a water conveying system. During a given period, a set of several pumping stations is working to deliver water from different sources at different locations. A multi-stage control process is considered whereby the total pumping time is divided into short sampling intervals. The intensity of pumping as a function of time is the control variable. It is assumed that there exists a reliable forecast of every pollutant as a function of time and water source. The amount of the pollutants is constrained in the final mass of water in the storage. The mass of water at the end of the operation period should be maximized</description><subject>Decision support systems</subject><subject>Effluents</subject><subject>Environmentally friendly manufacturing techniques</subject><subject>Industrial pollution</subject><subject>Monitoring</subject><subject>Quality management</subject><subject>Sampling methods</subject><subject>Water pollution</subject><subject>Water resources</subject><subject>Water storage</subject><isbn>0978672011</isbn><isbn>9780978672010</isbn><isbn>9780978672003</isbn><isbn>0978672003</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2006</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1T81KxDAYjIigrj178JIX6PolTZvkKOu6Ciu97H1J87NG2qQ0kcW3N6AehmGGYZhB6J7AmhCQj-_b5zUF6NYNFaIlF6iSXEBBx4vdXKLbf0HINapS-gQAIjvOgN2gvp-zn9SIpxh8josPJ6yCwZMK6mQnGzKODit8VtkuOJVEsfHZ5w88x3H8yj4GrGNIeVE-5HSHrpwak63-eIUOL9vD5rXe97u3zdO-9hJyrRkBZ00riFGmMWW2oU5TouWgOJPGgXXMGc00CE0HNfDWEg3c0tYIxmSzQg-_td5ae5yXcmH5PjJCmWx58wP8uVEP</recordid><startdate>200606</startdate><enddate>200606</enddate><creator>Ioslovich, I.</creator><creator>Gutman, P.-O.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200606</creationdate><title>Optimal monitoring and management of a water storage with pollution constraints</title><author>Ioslovich, I. ; Gutman, P.-O.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-c410fed581dad3d851d2fc21c9ba749df0ef4fdc4c08c2bab75e1c07e25d84493</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Decision support systems</topic><topic>Effluents</topic><topic>Environmentally friendly manufacturing techniques</topic><topic>Industrial pollution</topic><topic>Monitoring</topic><topic>Quality management</topic><topic>Sampling methods</topic><topic>Water pollution</topic><topic>Water resources</topic><topic>Water storage</topic><toplevel>online_resources</toplevel><creatorcontrib>Ioslovich, I.</creatorcontrib><creatorcontrib>Gutman, P.-O.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ioslovich, I.</au><au>Gutman, P.-O.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Optimal monitoring and management of a water storage with pollution constraints</atitle><btitle>2006 14th Mediterranean Conference on Control and Automation</btitle><stitle>MED</stitle><date>2006-06</date><risdate>2006</risdate><spage>1</spage><epage>6</epage><pages>1-6</pages><isbn>0978672011</isbn><isbn>9780978672010</isbn><eisbn>9780978672003</eisbn><eisbn>0978672003</eisbn><abstract>The aim is to fill water storage with potable water of a given quality, for subsequent treatment and distribution to a water conveying system. During a given period, a set of several pumping stations is working to deliver water from different sources at different locations. A multi-stage control process is considered whereby the total pumping time is divided into short sampling intervals. The intensity of pumping as a function of time is the control variable. It is assumed that there exists a reliable forecast of every pollutant as a function of time and water source. The amount of the pollutants is constrained in the final mass of water in the storage. The mass of water at the end of the operation period should be maximized</abstract><pub>IEEE</pub><doi>10.1109/MED.2006.328851</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 0978672011
ispartof 2006 14th Mediterranean Conference on Control and Automation, 2006, p.1-6
issn
language eng
recordid cdi_ieee_primary_4124957
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Decision support systems
Effluents
Environmentally friendly manufacturing techniques
Industrial pollution
Monitoring
Quality management
Sampling methods
Water pollution
Water resources
Water storage
title Optimal monitoring and management of a water storage with pollution constraints
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T20%3A34%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Optimal%20monitoring%20and%20management%20of%20a%20water%20storage%20with%20pollution%20constraints&rft.btitle=2006%2014th%20Mediterranean%20Conference%20on%20Control%20and%20Automation&rft.au=Ioslovich,%20I.&rft.date=2006-06&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.isbn=0978672011&rft.isbn_list=9780978672010&rft_id=info:doi/10.1109/MED.2006.328851&rft_dat=%3Cieee_6IE%3E4124957%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9780978672003&rft.eisbn_list=0978672003&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4124957&rfr_iscdi=true