Fault Location System for Transmission-Type Cable

A fault location system was developed for locating nonlinear faults on transmission-type cable. The fault locator measures the distance from terminal to fault as a fraction of the total cable length. A forward wave radar principle is used. The forward wave is generated by the cable breakdown at the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power apparatus and systems 1982-06, Vol.PAS-101 (6), p.1700-1710
Hauptverfasser: Gallagher, H. E., Mize, D. R., Dickerson, A. F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1710
container_issue 6
container_start_page 1700
container_title IEEE transactions on power apparatus and systems
container_volume PAS-101
creator Gallagher, H. E.
Mize, D. R.
Dickerson, A. F.
description A fault location system was developed for locating nonlinear faults on transmission-type cable. The fault locator measures the distance from terminal to fault as a fraction of the total cable length. A forward wave radar principle is used. The forward wave is generated by the cable breakdown at the fault. Laboratory and field tests indicate that nonlinear faults can be located to within ±10 m. Equipment modifications have been made to measure cable lengths to 10 km and longer. Further field tests and demonstration tests are planned.
doi_str_mv 10.1109/TPAS.1982.317222
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_4111509</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4111509</ieee_id><sourcerecordid>10_1109_TPAS_1982_317222</sourcerecordid><originalsourceid>FETCH-LOGICAL-c261t-a3ab194762da9cafedbf376aed77e6654377603d968bfbf966ee7ce9db87f1153</originalsourceid><addsrcrecordid>eNo9j8FKxDAURYMoWEf3gpv-QMa8pE2a5VAcFQoKU9chaV-g0k6HpC7697ZUXF243HPhEPIIbA_A9HP9eTjtQRd8L0Bxzq9IwrXOqRRcXJOEMSiozoHdkrsYvxkTTAIkBI72p5_Samzs1I3n9DTHCYfUjyGtgz3HoYtx6Wk9XzAtrevxntx420d8-Msd-Tq-1OUbrT5e38tDRRsuYaJWWAc6U5K3VjfWY-u8UNJiqxRKmWdCKclEq2XhvPNaSkTVoG5doTxALnaEbb9NGGMM6M0ldIMNswFmVmWzKptV2WzKC_K0IR0i_s8zWO6YFr8cCVKL</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Fault Location System for Transmission-Type Cable</title><source>IEEE Electronic Library (IEL)</source><creator>Gallagher, H. E. ; Mize, D. R. ; Dickerson, A. F.</creator><creatorcontrib>Gallagher, H. E. ; Mize, D. R. ; Dickerson, A. F.</creatorcontrib><description>A fault location system was developed for locating nonlinear faults on transmission-type cable. The fault locator measures the distance from terminal to fault as a fraction of the total cable length. A forward wave radar principle is used. The forward wave is generated by the cable breakdown at the fault. Laboratory and field tests indicate that nonlinear faults can be located to within ±10 m. Equipment modifications have been made to measure cable lengths to 10 km and longer. Further field tests and demonstration tests are planned.</description><identifier>ISSN: 0018-9510</identifier><identifier>EISSN: 2995-6323</identifier><identifier>DOI: 10.1109/TPAS.1982.317222</identifier><language>eng</language><publisher>IEEE</publisher><subject>Acoustic measurements ; Breakdown voltage ; Fault location ; Laboratories ; Length measurement ; Power cable insulation ; Power cables ; Radar ; Resonance ; Testing</subject><ispartof>IEEE transactions on power apparatus and systems, 1982-06, Vol.PAS-101 (6), p.1700-1710</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c261t-a3ab194762da9cafedbf376aed77e6654377603d968bfbf966ee7ce9db87f1153</citedby><cites>FETCH-LOGICAL-c261t-a3ab194762da9cafedbf376aed77e6654377603d968bfbf966ee7ce9db87f1153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4111509$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4111509$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Gallagher, H. E.</creatorcontrib><creatorcontrib>Mize, D. R.</creatorcontrib><creatorcontrib>Dickerson, A. F.</creatorcontrib><title>Fault Location System for Transmission-Type Cable</title><title>IEEE transactions on power apparatus and systems</title><addtitle>T-PAS</addtitle><description>A fault location system was developed for locating nonlinear faults on transmission-type cable. The fault locator measures the distance from terminal to fault as a fraction of the total cable length. A forward wave radar principle is used. The forward wave is generated by the cable breakdown at the fault. Laboratory and field tests indicate that nonlinear faults can be located to within ±10 m. Equipment modifications have been made to measure cable lengths to 10 km and longer. Further field tests and demonstration tests are planned.</description><subject>Acoustic measurements</subject><subject>Breakdown voltage</subject><subject>Fault location</subject><subject>Laboratories</subject><subject>Length measurement</subject><subject>Power cable insulation</subject><subject>Power cables</subject><subject>Radar</subject><subject>Resonance</subject><subject>Testing</subject><issn>0018-9510</issn><issn>2995-6323</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1982</creationdate><recordtype>article</recordtype><recordid>eNo9j8FKxDAURYMoWEf3gpv-QMa8pE2a5VAcFQoKU9chaV-g0k6HpC7697ZUXF243HPhEPIIbA_A9HP9eTjtQRd8L0Bxzq9IwrXOqRRcXJOEMSiozoHdkrsYvxkTTAIkBI72p5_Samzs1I3n9DTHCYfUjyGtgz3HoYtx6Wk9XzAtrevxntx420d8-Msd-Tq-1OUbrT5e38tDRRsuYaJWWAc6U5K3VjfWY-u8UNJiqxRKmWdCKclEq2XhvPNaSkTVoG5doTxALnaEbb9NGGMM6M0ldIMNswFmVmWzKptV2WzKC_K0IR0i_s8zWO6YFr8cCVKL</recordid><startdate>198206</startdate><enddate>198206</enddate><creator>Gallagher, H. E.</creator><creator>Mize, D. R.</creator><creator>Dickerson, A. F.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>198206</creationdate><title>Fault Location System for Transmission-Type Cable</title><author>Gallagher, H. E. ; Mize, D. R. ; Dickerson, A. F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c261t-a3ab194762da9cafedbf376aed77e6654377603d968bfbf966ee7ce9db87f1153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1982</creationdate><topic>Acoustic measurements</topic><topic>Breakdown voltage</topic><topic>Fault location</topic><topic>Laboratories</topic><topic>Length measurement</topic><topic>Power cable insulation</topic><topic>Power cables</topic><topic>Radar</topic><topic>Resonance</topic><topic>Testing</topic><toplevel>online_resources</toplevel><creatorcontrib>Gallagher, H. E.</creatorcontrib><creatorcontrib>Mize, D. R.</creatorcontrib><creatorcontrib>Dickerson, A. F.</creatorcontrib><collection>CrossRef</collection><jtitle>IEEE transactions on power apparatus and systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Gallagher, H. E.</au><au>Mize, D. R.</au><au>Dickerson, A. F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fault Location System for Transmission-Type Cable</atitle><jtitle>IEEE transactions on power apparatus and systems</jtitle><stitle>T-PAS</stitle><date>1982-06</date><risdate>1982</risdate><volume>PAS-101</volume><issue>6</issue><spage>1700</spage><epage>1710</epage><pages>1700-1710</pages><issn>0018-9510</issn><eissn>2995-6323</eissn><abstract>A fault location system was developed for locating nonlinear faults on transmission-type cable. The fault locator measures the distance from terminal to fault as a fraction of the total cable length. A forward wave radar principle is used. The forward wave is generated by the cable breakdown at the fault. Laboratory and field tests indicate that nonlinear faults can be located to within ±10 m. Equipment modifications have been made to measure cable lengths to 10 km and longer. Further field tests and demonstration tests are planned.</abstract><pub>IEEE</pub><doi>10.1109/TPAS.1982.317222</doi><tpages>11</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9510
ispartof IEEE transactions on power apparatus and systems, 1982-06, Vol.PAS-101 (6), p.1700-1710
issn 0018-9510
2995-6323
language eng
recordid cdi_ieee_primary_4111509
source IEEE Electronic Library (IEL)
subjects Acoustic measurements
Breakdown voltage
Fault location
Laboratories
Length measurement
Power cable insulation
Power cables
Radar
Resonance
Testing
title Fault Location System for Transmission-Type Cable
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T05%3A36%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fault%20Location%20System%20for%20Transmission-Type%20Cable&rft.jtitle=IEEE%20transactions%20on%20power%20apparatus%20and%20systems&rft.au=Gallagher,%20H.%20E.&rft.date=1982-06&rft.volume=PAS-101&rft.issue=6&rft.spage=1700&rft.epage=1710&rft.pages=1700-1710&rft.issn=0018-9510&rft.eissn=2995-6323&rft_id=info:doi/10.1109/TPAS.1982.317222&rft_dat=%3Ccrossref_RIE%3E10_1109_TPAS_1982_317222%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4111509&rfr_iscdi=true