Studies of On-line Monitoring of Pressure in Vacuum Interrupters
Some methods for on-line monitoring of pressure in vacuum interrupters were reviewed. Experiments were carried out to investigate the characteristics of an inverted magnetron vacuum gauge in pulsed discharge mode, which can measure pressures ranging from 3times10 -4 Pa to 0.5 Pa. According to the ex...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1855 |
---|---|
container_issue | |
container_start_page | 1851 |
container_title | |
container_volume | |
creator | Huiyong Mao Yi Wang |
description | Some methods for on-line monitoring of pressure in vacuum interrupters were reviewed. Experiments were carried out to investigate the characteristics of an inverted magnetron vacuum gauge in pulsed discharge mode, which can measure pressures ranging from 3times10 -4 Pa to 0.5 Pa. According to the experimental results, a kind of vacuum tube with intellectualized vacuum sensor was developed to implement the on-line monitoring of pressure in vacuum interrupters. Discharge in the vacuum sensor was performed in a pulsed mode. The vacuum sensor was powered by batteries and was able to communicate the results of measurement to other devices by radio, infrared or optical fibre |
doi_str_mv | 10.1109/PSCE.2006.296194 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4076020</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4076020</ieee_id><sourcerecordid>4076020</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-4d713a3a04ab4f625f8cd85df1802f9db9995f976877656a9663991ba8c668fc3</originalsourceid><addsrcrecordid>eNo1jE1Lw0AURUdEUGv2gpv8gcQ33_N2SqhaqLRQFXdlkszISDspM8nCf29FvYt7uGdxCbmmUFMKeLveNPOaAaiaoaIoTsglFUwIoNq8n5ICtfnfmp2TIudPOIajNMAvyN1mnPrgcjn4chWrXYiufB5iGIcU4sePXSeX85RcGWL5Zrtp2peLOLqUpsOx8xU583aXXfHHGXl9mL80T9Vy9bho7pdVoFqOleg15ZZbELYVXjHpTdcb2XtqgHnsW0SUHrUyWiupLCrFEWlrTaeU8R2fkZvf3-Cc2x5S2Nv0tRWgFTDg33UhSco</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Studies of On-line Monitoring of Pressure in Vacuum Interrupters</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Huiyong Mao ; Yi Wang</creator><creatorcontrib>Huiyong Mao ; Yi Wang</creatorcontrib><description>Some methods for on-line monitoring of pressure in vacuum interrupters were reviewed. Experiments were carried out to investigate the characteristics of an inverted magnetron vacuum gauge in pulsed discharge mode, which can measure pressures ranging from 3times10 -4 Pa to 0.5 Pa. According to the experimental results, a kind of vacuum tube with intellectualized vacuum sensor was developed to implement the on-line monitoring of pressure in vacuum interrupters. Discharge in the vacuum sensor was performed in a pulsed mode. The vacuum sensor was powered by batteries and was able to communicate the results of measurement to other devices by radio, infrared or optical fibre</description><identifier>ISBN: 9781424401772</identifier><identifier>ISBN: 1424401771</identifier><identifier>EISBN: 142440178X</identifier><identifier>EISBN: 9781424401789</identifier><identifier>DOI: 10.1109/PSCE.2006.296194</identifier><language>eng</language><subject>Electron tubes ; Infrared sensors ; Interrupters ; Magnetic sensors ; Monitoring ; Optical fiber sensors ; Optical pulses ; Pressure measurement ; Pulse measurements ; Sensor phenomena and characterization</subject><ispartof>2006 IEEE PES Power Systems Conference and Exposition, 2006, p.1851-1855</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4076020$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,27924,54919</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4076020$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Huiyong Mao</creatorcontrib><creatorcontrib>Yi Wang</creatorcontrib><title>Studies of On-line Monitoring of Pressure in Vacuum Interrupters</title><title>2006 IEEE PES Power Systems Conference and Exposition</title><addtitle>PSCE</addtitle><description>Some methods for on-line monitoring of pressure in vacuum interrupters were reviewed. Experiments were carried out to investigate the characteristics of an inverted magnetron vacuum gauge in pulsed discharge mode, which can measure pressures ranging from 3times10 -4 Pa to 0.5 Pa. According to the experimental results, a kind of vacuum tube with intellectualized vacuum sensor was developed to implement the on-line monitoring of pressure in vacuum interrupters. Discharge in the vacuum sensor was performed in a pulsed mode. The vacuum sensor was powered by batteries and was able to communicate the results of measurement to other devices by radio, infrared or optical fibre</description><subject>Electron tubes</subject><subject>Infrared sensors</subject><subject>Interrupters</subject><subject>Magnetic sensors</subject><subject>Monitoring</subject><subject>Optical fiber sensors</subject><subject>Optical pulses</subject><subject>Pressure measurement</subject><subject>Pulse measurements</subject><subject>Sensor phenomena and characterization</subject><isbn>9781424401772</isbn><isbn>1424401771</isbn><isbn>142440178X</isbn><isbn>9781424401789</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2006</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1jE1Lw0AURUdEUGv2gpv8gcQ33_N2SqhaqLRQFXdlkszISDspM8nCf29FvYt7uGdxCbmmUFMKeLveNPOaAaiaoaIoTsglFUwIoNq8n5ICtfnfmp2TIudPOIajNMAvyN1mnPrgcjn4chWrXYiufB5iGIcU4sePXSeX85RcGWL5Zrtp2peLOLqUpsOx8xU583aXXfHHGXl9mL80T9Vy9bho7pdVoFqOleg15ZZbELYVXjHpTdcb2XtqgHnsW0SUHrUyWiupLCrFEWlrTaeU8R2fkZvf3-Cc2x5S2Nv0tRWgFTDg33UhSco</recordid><startdate>20061029</startdate><enddate>20061029</enddate><creator>Huiyong Mao</creator><creator>Yi Wang</creator><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>20061029</creationdate><title>Studies of On-line Monitoring of Pressure in Vacuum Interrupters</title><author>Huiyong Mao ; Yi Wang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-4d713a3a04ab4f625f8cd85df1802f9db9995f976877656a9663991ba8c668fc3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Electron tubes</topic><topic>Infrared sensors</topic><topic>Interrupters</topic><topic>Magnetic sensors</topic><topic>Monitoring</topic><topic>Optical fiber sensors</topic><topic>Optical pulses</topic><topic>Pressure measurement</topic><topic>Pulse measurements</topic><topic>Sensor phenomena and characterization</topic><toplevel>online_resources</toplevel><creatorcontrib>Huiyong Mao</creatorcontrib><creatorcontrib>Yi Wang</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Huiyong Mao</au><au>Yi Wang</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Studies of On-line Monitoring of Pressure in Vacuum Interrupters</atitle><btitle>2006 IEEE PES Power Systems Conference and Exposition</btitle><stitle>PSCE</stitle><date>2006-10-29</date><risdate>2006</risdate><spage>1851</spage><epage>1855</epage><pages>1851-1855</pages><isbn>9781424401772</isbn><isbn>1424401771</isbn><eisbn>142440178X</eisbn><eisbn>9781424401789</eisbn><abstract>Some methods for on-line monitoring of pressure in vacuum interrupters were reviewed. Experiments were carried out to investigate the characteristics of an inverted magnetron vacuum gauge in pulsed discharge mode, which can measure pressures ranging from 3times10 -4 Pa to 0.5 Pa. According to the experimental results, a kind of vacuum tube with intellectualized vacuum sensor was developed to implement the on-line monitoring of pressure in vacuum interrupters. Discharge in the vacuum sensor was performed in a pulsed mode. The vacuum sensor was powered by batteries and was able to communicate the results of measurement to other devices by radio, infrared or optical fibre</abstract><doi>10.1109/PSCE.2006.296194</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9781424401772 |
ispartof | 2006 IEEE PES Power Systems Conference and Exposition, 2006, p.1851-1855 |
issn | |
language | eng |
recordid | cdi_ieee_primary_4076020 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Electron tubes Infrared sensors Interrupters Magnetic sensors Monitoring Optical fiber sensors Optical pulses Pressure measurement Pulse measurements Sensor phenomena and characterization |
title | Studies of On-line Monitoring of Pressure in Vacuum Interrupters |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T06%3A33%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Studies%20of%20On-line%20Monitoring%20of%20Pressure%20in%20Vacuum%20Interrupters&rft.btitle=2006%20IEEE%20PES%20Power%20Systems%20Conference%20and%20Exposition&rft.au=Huiyong%20Mao&rft.date=2006-10-29&rft.spage=1851&rft.epage=1855&rft.pages=1851-1855&rft.isbn=9781424401772&rft.isbn_list=1424401771&rft_id=info:doi/10.1109/PSCE.2006.296194&rft_dat=%3Cieee_6IE%3E4076020%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=142440178X&rft.eisbn_list=9781424401789&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4076020&rfr_iscdi=true |