An Electromagnetic Probe for Detecting and Locating Discharges in Large Rotating-Machine Stators
The detection and location of discharges in rotating- machine high-voltage windings is useful in directing attention to abnormalities in the insulation structure which can lead to premature failure of the winding. In order to achieve a practically useful test it is necessary to distinguish between c...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power apparatus and systems 1969-03, Vol.PAS-88 (3), p.251-257 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 257 |
---|---|
container_issue | 3 |
container_start_page | 251 |
container_title | IEEE transactions on power apparatus and systems |
container_volume | PAS-88 |
creator | Dakin, Thomas W. Works, Carroll N. Johnson, John S. |
description | The detection and location of discharges in rotating- machine high-voltage windings is useful in directing attention to abnormalities in the insulation structure which can lead to premature failure of the winding. In order to achieve a practically useful test it is necessary to distinguish between conditions involving many small size voids which are not severely limiting and relatively few large voids. |
doi_str_mv | 10.1109/TPAS.1969.292314 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_4073824</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4073824</ieee_id><sourcerecordid>10_1109_TPAS_1969_292314</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-9cf67a98aa14fadadadb2cf4464125b90409c7a35732281fc5ef77f8a4320bb3</originalsourceid><addsrcrecordid>eNo9kM1PAjEQxRujiYjeTbz0H1icabsfPRLAj2SNRLivs6WFGtiadi_-97JgzBxmXt68d_gxdo8wQQT9uF5OVxPUhZ4ILSSqCzYSWudZIYW8ZCMArDKdI1yzm5S-ACQUiCP2Oe34Ym9NH8OBtp3tveHLGFrLXYh8bvuj5bstp27D62DoJOY-mR3FrU3cd7weLv4R-pOZvZHZ-c7y1VGHmG7ZlaN9snd_e8zWT4v17CWr359fZ9M6M1LoPtPGFSXpigiVo80wrTBOqUKhyFsNCrQpSealFKJCZ3LrytJVpKSAtpVjBudaE0NK0brmO_oDxZ8GoRkANQOgZgDUnAEdIw_niLfW_r8rKGUllPwFDHNi-g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>An Electromagnetic Probe for Detecting and Locating Discharges in Large Rotating-Machine Stators</title><source>IEEE Electronic Library (IEL)</source><creator>Dakin, Thomas W. ; Works, Carroll N. ; Johnson, John S.</creator><creatorcontrib>Dakin, Thomas W. ; Works, Carroll N. ; Johnson, John S.</creatorcontrib><description>The detection and location of discharges in rotating- machine high-voltage windings is useful in directing attention to abnormalities in the insulation structure which can lead to premature failure of the winding. In order to achieve a practically useful test it is necessary to distinguish between conditions involving many small size voids which are not severely limiting and relatively few large voids.</description><identifier>ISSN: 0018-9510</identifier><identifier>EISSN: 2995-6323</identifier><identifier>DOI: 10.1109/TPAS.1969.292314</identifier><language>eng</language><publisher>IEEE</publisher><subject>Coils ; Corona ; Coupling circuits ; Fault location ; Insulation ; Probes ; Pulse measurements ; Stator windings ; Surface discharges ; Testing</subject><ispartof>IEEE transactions on power apparatus and systems, 1969-03, Vol.PAS-88 (3), p.251-257</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-9cf67a98aa14fadadadb2cf4464125b90409c7a35732281fc5ef77f8a4320bb3</citedby><cites>FETCH-LOGICAL-c329t-9cf67a98aa14fadadadb2cf4464125b90409c7a35732281fc5ef77f8a4320bb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4073824$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27922,27923,54756</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4073824$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Dakin, Thomas W.</creatorcontrib><creatorcontrib>Works, Carroll N.</creatorcontrib><creatorcontrib>Johnson, John S.</creatorcontrib><title>An Electromagnetic Probe for Detecting and Locating Discharges in Large Rotating-Machine Stators</title><title>IEEE transactions on power apparatus and systems</title><addtitle>T-PAS</addtitle><description>The detection and location of discharges in rotating- machine high-voltage windings is useful in directing attention to abnormalities in the insulation structure which can lead to premature failure of the winding. In order to achieve a practically useful test it is necessary to distinguish between conditions involving many small size voids which are not severely limiting and relatively few large voids.</description><subject>Coils</subject><subject>Corona</subject><subject>Coupling circuits</subject><subject>Fault location</subject><subject>Insulation</subject><subject>Probes</subject><subject>Pulse measurements</subject><subject>Stator windings</subject><subject>Surface discharges</subject><subject>Testing</subject><issn>0018-9510</issn><issn>2995-6323</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1969</creationdate><recordtype>article</recordtype><recordid>eNo9kM1PAjEQxRujiYjeTbz0H1icabsfPRLAj2SNRLivs6WFGtiadi_-97JgzBxmXt68d_gxdo8wQQT9uF5OVxPUhZ4ILSSqCzYSWudZIYW8ZCMArDKdI1yzm5S-ACQUiCP2Oe34Ym9NH8OBtp3tveHLGFrLXYh8bvuj5bstp27D62DoJOY-mR3FrU3cd7weLv4R-pOZvZHZ-c7y1VGHmG7ZlaN9snd_e8zWT4v17CWr359fZ9M6M1LoPtPGFSXpigiVo80wrTBOqUKhyFsNCrQpSealFKJCZ3LrytJVpKSAtpVjBudaE0NK0brmO_oDxZ8GoRkANQOgZgDUnAEdIw_niLfW_r8rKGUllPwFDHNi-g</recordid><startdate>196903</startdate><enddate>196903</enddate><creator>Dakin, Thomas W.</creator><creator>Works, Carroll N.</creator><creator>Johnson, John S.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>196903</creationdate><title>An Electromagnetic Probe for Detecting and Locating Discharges in Large Rotating-Machine Stators</title><author>Dakin, Thomas W. ; Works, Carroll N. ; Johnson, John S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-9cf67a98aa14fadadadb2cf4464125b90409c7a35732281fc5ef77f8a4320bb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1969</creationdate><topic>Coils</topic><topic>Corona</topic><topic>Coupling circuits</topic><topic>Fault location</topic><topic>Insulation</topic><topic>Probes</topic><topic>Pulse measurements</topic><topic>Stator windings</topic><topic>Surface discharges</topic><topic>Testing</topic><toplevel>online_resources</toplevel><creatorcontrib>Dakin, Thomas W.</creatorcontrib><creatorcontrib>Works, Carroll N.</creatorcontrib><creatorcontrib>Johnson, John S.</creatorcontrib><collection>CrossRef</collection><jtitle>IEEE transactions on power apparatus and systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Dakin, Thomas W.</au><au>Works, Carroll N.</au><au>Johnson, John S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An Electromagnetic Probe for Detecting and Locating Discharges in Large Rotating-Machine Stators</atitle><jtitle>IEEE transactions on power apparatus and systems</jtitle><stitle>T-PAS</stitle><date>1969-03</date><risdate>1969</risdate><volume>PAS-88</volume><issue>3</issue><spage>251</spage><epage>257</epage><pages>251-257</pages><issn>0018-9510</issn><eissn>2995-6323</eissn><abstract>The detection and location of discharges in rotating- machine high-voltage windings is useful in directing attention to abnormalities in the insulation structure which can lead to premature failure of the winding. In order to achieve a practically useful test it is necessary to distinguish between conditions involving many small size voids which are not severely limiting and relatively few large voids.</abstract><pub>IEEE</pub><doi>10.1109/TPAS.1969.292314</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9510 |
ispartof | IEEE transactions on power apparatus and systems, 1969-03, Vol.PAS-88 (3), p.251-257 |
issn | 0018-9510 2995-6323 |
language | eng |
recordid | cdi_ieee_primary_4073824 |
source | IEEE Electronic Library (IEL) |
subjects | Coils Corona Coupling circuits Fault location Insulation Probes Pulse measurements Stator windings Surface discharges Testing |
title | An Electromagnetic Probe for Detecting and Locating Discharges in Large Rotating-Machine Stators |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T07%3A43%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20Electromagnetic%20Probe%20for%20Detecting%20and%20Locating%20Discharges%20in%20Large%20Rotating-Machine%20Stators&rft.jtitle=IEEE%20transactions%20on%20power%20apparatus%20and%20systems&rft.au=Dakin,%20Thomas%20W.&rft.date=1969-03&rft.volume=PAS-88&rft.issue=3&rft.spage=251&rft.epage=257&rft.pages=251-257&rft.issn=0018-9510&rft.eissn=2995-6323&rft_id=info:doi/10.1109/TPAS.1969.292314&rft_dat=%3Ccrossref_RIE%3E10_1109_TPAS_1969_292314%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4073824&rfr_iscdi=true |