Nonlinear response in thin film magnetometer sense loops at 77 K
The onset of nonlinear response to applied magnetic field in GdBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// thin film magnetometer sense loops was measured in equipment performing at 77 K. As the magnetic field applied to the magnetometers was ramped, the output magnetic flux of the sense loops was monito...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 1995-06, Vol.5 (2), p.3123-3126 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3126 |
---|---|
container_issue | 2 |
container_start_page | 3123 |
container_title | IEEE transactions on applied superconductivity |
container_volume | 5 |
creator | Purpura, J.W. Clem, T.R. Wiegert, R.F. |
description | The onset of nonlinear response to applied magnetic field in GdBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// thin film magnetometer sense loops was measured in equipment performing at 77 K. As the magnetic field applied to the magnetometers was ramped, the output magnetic flux of the sense loops was monitored with a YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// DC superconducting quantum interference device flip-chip coupled to the loop sample's output washer. In experiments devised to minimize circulating current in the magnetometers, nonlinear onset fields ranging from 26 to 120 /spl mu/T were measured for samples having linewidths ranging from 20 to 800 /spl mu/m. The loops also exhibited hysteresis in conjunction with the nonlinear behavior. These results indicate that nonlinear hysteresis is an issue for magnetometer loops operating in the Earth's field.< > |
doi_str_mv | 10.1109/77.403253 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_ieee_primary_403253</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>403253</ieee_id><sourcerecordid>28420785</sourcerecordid><originalsourceid>FETCH-LOGICAL-c312t-b4de1f1e716d4b860cfb47a2439ceaab7734605cda96f942e6b84856a7baded23</originalsourceid><addsrcrecordid>eNo90D1PwzAQBmALgUQpDKxMnpAYUvwZOxuoKh-iggVmy3bOEJTEwU4H_j2pUrHcnfQ-uuFF6JKSFaWkulVqJQhnkh-hBZVSF0xSeTzdRNJCM8ZP0VnO34RQoYVcoLvX2LdNDzbhBHmIfQbc9Hj8mkZo2g539rOHMXYwQsIZ9nkb45CxHbFS-OUcnQTbZrg47CX6eNi8r5-K7dvj8_p-W3hO2Vg4UQMNFBQta-F0SXxwQlkmeOXBWqcUFyWRvrZVGSrBoHRaaFla5WwNNeNLdD3_HVL82UEeTddkD21re4i7bJgWjCgtJ3gzQ59izgmCGVLT2fRrKDH7joxSZu5oslezbQDg3x3CP7EKYNQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28420785</pqid></control><display><type>article</type><title>Nonlinear response in thin film magnetometer sense loops at 77 K</title><source>IEEE Electronic Library (IEL)</source><creator>Purpura, J.W. ; Clem, T.R. ; Wiegert, R.F.</creator><creatorcontrib>Purpura, J.W. ; Clem, T.R. ; Wiegert, R.F.</creatorcontrib><description>The onset of nonlinear response to applied magnetic field in GdBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// thin film magnetometer sense loops was measured in equipment performing at 77 K. As the magnetic field applied to the magnetometers was ramped, the output magnetic flux of the sense loops was monitored with a YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// DC superconducting quantum interference device flip-chip coupled to the loop sample's output washer. In experiments devised to minimize circulating current in the magnetometers, nonlinear onset fields ranging from 26 to 120 /spl mu/T were measured for samples having linewidths ranging from 20 to 800 /spl mu/m. The loops also exhibited hysteresis in conjunction with the nonlinear behavior. These results indicate that nonlinear hysteresis is an issue for magnetometer loops operating in the Earth's field.< ></description><identifier>ISSN: 1051-8223</identifier><identifier>EISSN: 1558-2515</identifier><identifier>DOI: 10.1109/77.403253</identifier><identifier>CODEN: ITASE9</identifier><language>eng</language><publisher>IEEE</publisher><subject>Magnetic field measurement ; Magnetic films ; Magnetic flux ; Magnetic hysteresis ; Monitoring ; Performance evaluation ; SQUID magnetometers ; Superconducting devices ; Thin film devices ; Transistors</subject><ispartof>IEEE transactions on applied superconductivity, 1995-06, Vol.5 (2), p.3123-3126</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c312t-b4de1f1e716d4b860cfb47a2439ceaab7734605cda96f942e6b84856a7baded23</citedby><cites>FETCH-LOGICAL-c312t-b4de1f1e716d4b860cfb47a2439ceaab7734605cda96f942e6b84856a7baded23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/403253$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/403253$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Purpura, J.W.</creatorcontrib><creatorcontrib>Clem, T.R.</creatorcontrib><creatorcontrib>Wiegert, R.F.</creatorcontrib><title>Nonlinear response in thin film magnetometer sense loops at 77 K</title><title>IEEE transactions on applied superconductivity</title><addtitle>TASC</addtitle><description>The onset of nonlinear response to applied magnetic field in GdBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// thin film magnetometer sense loops was measured in equipment performing at 77 K. As the magnetic field applied to the magnetometers was ramped, the output magnetic flux of the sense loops was monitored with a YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// DC superconducting quantum interference device flip-chip coupled to the loop sample's output washer. In experiments devised to minimize circulating current in the magnetometers, nonlinear onset fields ranging from 26 to 120 /spl mu/T were measured for samples having linewidths ranging from 20 to 800 /spl mu/m. The loops also exhibited hysteresis in conjunction with the nonlinear behavior. These results indicate that nonlinear hysteresis is an issue for magnetometer loops operating in the Earth's field.< ></description><subject>Magnetic field measurement</subject><subject>Magnetic films</subject><subject>Magnetic flux</subject><subject>Magnetic hysteresis</subject><subject>Monitoring</subject><subject>Performance evaluation</subject><subject>SQUID magnetometers</subject><subject>Superconducting devices</subject><subject>Thin film devices</subject><subject>Transistors</subject><issn>1051-8223</issn><issn>1558-2515</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNo90D1PwzAQBmALgUQpDKxMnpAYUvwZOxuoKh-iggVmy3bOEJTEwU4H_j2pUrHcnfQ-uuFF6JKSFaWkulVqJQhnkh-hBZVSF0xSeTzdRNJCM8ZP0VnO34RQoYVcoLvX2LdNDzbhBHmIfQbc9Hj8mkZo2g539rOHMXYwQsIZ9nkb45CxHbFS-OUcnQTbZrg47CX6eNi8r5-K7dvj8_p-W3hO2Vg4UQMNFBQta-F0SXxwQlkmeOXBWqcUFyWRvrZVGSrBoHRaaFla5WwNNeNLdD3_HVL82UEeTddkD21re4i7bJgWjCgtJ3gzQ59izgmCGVLT2fRrKDH7joxSZu5oslezbQDg3x3CP7EKYNQ</recordid><startdate>19950601</startdate><enddate>19950601</enddate><creator>Purpura, J.W.</creator><creator>Clem, T.R.</creator><creator>Wiegert, R.F.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19950601</creationdate><title>Nonlinear response in thin film magnetometer sense loops at 77 K</title><author>Purpura, J.W. ; Clem, T.R. ; Wiegert, R.F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c312t-b4de1f1e716d4b860cfb47a2439ceaab7734605cda96f942e6b84856a7baded23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Magnetic field measurement</topic><topic>Magnetic films</topic><topic>Magnetic flux</topic><topic>Magnetic hysteresis</topic><topic>Monitoring</topic><topic>Performance evaluation</topic><topic>SQUID magnetometers</topic><topic>Superconducting devices</topic><topic>Thin film devices</topic><topic>Transistors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Purpura, J.W.</creatorcontrib><creatorcontrib>Clem, T.R.</creatorcontrib><creatorcontrib>Wiegert, R.F.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on applied superconductivity</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Purpura, J.W.</au><au>Clem, T.R.</au><au>Wiegert, R.F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Nonlinear response in thin film magnetometer sense loops at 77 K</atitle><jtitle>IEEE transactions on applied superconductivity</jtitle><stitle>TASC</stitle><date>1995-06-01</date><risdate>1995</risdate><volume>5</volume><issue>2</issue><spage>3123</spage><epage>3126</epage><pages>3123-3126</pages><issn>1051-8223</issn><eissn>1558-2515</eissn><coden>ITASE9</coden><abstract>The onset of nonlinear response to applied magnetic field in GdBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// thin film magnetometer sense loops was measured in equipment performing at 77 K. As the magnetic field applied to the magnetometers was ramped, the output magnetic flux of the sense loops was monitored with a YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// DC superconducting quantum interference device flip-chip coupled to the loop sample's output washer. In experiments devised to minimize circulating current in the magnetometers, nonlinear onset fields ranging from 26 to 120 /spl mu/T were measured for samples having linewidths ranging from 20 to 800 /spl mu/m. The loops also exhibited hysteresis in conjunction with the nonlinear behavior. These results indicate that nonlinear hysteresis is an issue for magnetometer loops operating in the Earth's field.< ></abstract><pub>IEEE</pub><doi>10.1109/77.403253</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1051-8223 |
ispartof | IEEE transactions on applied superconductivity, 1995-06, Vol.5 (2), p.3123-3126 |
issn | 1051-8223 1558-2515 |
language | eng |
recordid | cdi_ieee_primary_403253 |
source | IEEE Electronic Library (IEL) |
subjects | Magnetic field measurement Magnetic films Magnetic flux Magnetic hysteresis Monitoring Performance evaluation SQUID magnetometers Superconducting devices Thin film devices Transistors |
title | Nonlinear response in thin film magnetometer sense loops at 77 K |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T23%3A36%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Nonlinear%20response%20in%20thin%20film%20magnetometer%20sense%20loops%20at%2077%20K&rft.jtitle=IEEE%20transactions%20on%20applied%20superconductivity&rft.au=Purpura,%20J.W.&rft.date=1995-06-01&rft.volume=5&rft.issue=2&rft.spage=3123&rft.epage=3126&rft.pages=3123-3126&rft.issn=1051-8223&rft.eissn=1558-2515&rft.coden=ITASE9&rft_id=info:doi/10.1109/77.403253&rft_dat=%3Cproquest_RIE%3E28420785%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28420785&rft_id=info:pmid/&rft_ieee_id=403253&rfr_iscdi=true |