Arc detection for telephone DC power distribution systems

Arcing faults may occur in DC power distribution systems in telephone offices. Fuses and circuit breakers are not intended to protect against arcing faults. Therefore, the detection of arcing faults is a prime concern to help prevent fire ignition and the resulting damage caused by fire and its by-p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Boskiner, J., Silverman, E.J.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 344 vol.2
container_issue
container_start_page 341
container_title
container_volume 2
creator Boskiner, J.
Silverman, E.J.
description Arcing faults may occur in DC power distribution systems in telephone offices. Fuses and circuit breakers are not intended to protect against arcing faults. Therefore, the detection of arcing faults is a prime concern to help prevent fire ignition and the resulting damage caused by fire and its by-products. This paper describes a method to help detect arcing faults in telephone offices. It includes the work determining arc signatures and noise spectra in working, nonarcing, DC power distribution systems. Also, field and laboratory experiments investigating the performance of an experimental prototype arc detection system are described. Possible applications of an arc detection system are included.< >
doi_str_mv 10.1109/INTLEC.1993.388549
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_388549</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>388549</ieee_id><sourcerecordid>388549</sourcerecordid><originalsourceid>FETCH-LOGICAL-i174t-37b6039cc0bec8f6f96b194638cc8ab5a3e9fbf4c70324058f1fdae8919e7c033</originalsourceid><addsrcrecordid>eNotj9FKwzAUhgMiqHMvsKu8QOtJT9rmXI46dVD0Zl6PJj3ByLaWJCJ7e8X533w3Hx_8QqwUlEoBPWxfd_2mKxURlmhMrelK3EFrAJXRFdyIZUqf8Dtdq6qmW0Hr6OTImV0O00n6KcrMB54_phPLx07O0zdHOYaUY7Bff046p8zHdC-u_XBIvPznQrw_bXbdS9G_PW-7dV8E1epcYGsbQHIOLDvjG0-NVaQbNM6ZwdYDMnnrtWsBKw218cqPAxtSxK0DxIVYXbqBmfdzDMchnveXc_gD6_FF6g</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Arc detection for telephone DC power distribution systems</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Boskiner, J. ; Silverman, E.J.</creator><creatorcontrib>Boskiner, J. ; Silverman, E.J.</creatorcontrib><description>Arcing faults may occur in DC power distribution systems in telephone offices. Fuses and circuit breakers are not intended to protect against arcing faults. Therefore, the detection of arcing faults is a prime concern to help prevent fire ignition and the resulting damage caused by fire and its by-products. This paper describes a method to help detect arcing faults in telephone offices. It includes the work determining arc signatures and noise spectra in working, nonarcing, DC power distribution systems. Also, field and laboratory experiments investigating the performance of an experimental prototype arc detection system are described. Possible applications of an arc detection system are included.&lt; &gt;</description><identifier>ISBN: 0780318420</identifier><identifier>ISBN: 9780780318427</identifier><identifier>DOI: 10.1109/INTLEC.1993.388549</identifier><language>eng</language><publisher>IEEE</publisher><subject>Circuit breakers ; Circuit faults ; Electrical fault detection ; Fault detection ; Fires ; Fuses ; Ignition ; Power distribution ; Power system protection ; Telephony</subject><ispartof>Proceedings of Intelec 93: 15th International Telecommunications Energy Conference, 1993, Vol.2, p.341-344 vol.2</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/388549$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/388549$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Boskiner, J.</creatorcontrib><creatorcontrib>Silverman, E.J.</creatorcontrib><title>Arc detection for telephone DC power distribution systems</title><title>Proceedings of Intelec 93: 15th International Telecommunications Energy Conference</title><addtitle>INTLEC</addtitle><description>Arcing faults may occur in DC power distribution systems in telephone offices. Fuses and circuit breakers are not intended to protect against arcing faults. Therefore, the detection of arcing faults is a prime concern to help prevent fire ignition and the resulting damage caused by fire and its by-products. This paper describes a method to help detect arcing faults in telephone offices. It includes the work determining arc signatures and noise spectra in working, nonarcing, DC power distribution systems. Also, field and laboratory experiments investigating the performance of an experimental prototype arc detection system are described. Possible applications of an arc detection system are included.&lt; &gt;</description><subject>Circuit breakers</subject><subject>Circuit faults</subject><subject>Electrical fault detection</subject><subject>Fault detection</subject><subject>Fires</subject><subject>Fuses</subject><subject>Ignition</subject><subject>Power distribution</subject><subject>Power system protection</subject><subject>Telephony</subject><isbn>0780318420</isbn><isbn>9780780318427</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1993</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj9FKwzAUhgMiqHMvsKu8QOtJT9rmXI46dVD0Zl6PJj3ByLaWJCJ7e8X533w3Hx_8QqwUlEoBPWxfd_2mKxURlmhMrelK3EFrAJXRFdyIZUqf8Dtdq6qmW0Hr6OTImV0O00n6KcrMB54_phPLx07O0zdHOYaUY7Bff046p8zHdC-u_XBIvPznQrw_bXbdS9G_PW-7dV8E1epcYGsbQHIOLDvjG0-NVaQbNM6ZwdYDMnnrtWsBKw218cqPAxtSxK0DxIVYXbqBmfdzDMchnveXc_gD6_FF6g</recordid><startdate>1993</startdate><enddate>1993</enddate><creator>Boskiner, J.</creator><creator>Silverman, E.J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>1993</creationdate><title>Arc detection for telephone DC power distribution systems</title><author>Boskiner, J. ; Silverman, E.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i174t-37b6039cc0bec8f6f96b194638cc8ab5a3e9fbf4c70324058f1fdae8919e7c033</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Circuit breakers</topic><topic>Circuit faults</topic><topic>Electrical fault detection</topic><topic>Fault detection</topic><topic>Fires</topic><topic>Fuses</topic><topic>Ignition</topic><topic>Power distribution</topic><topic>Power system protection</topic><topic>Telephony</topic><toplevel>online_resources</toplevel><creatorcontrib>Boskiner, J.</creatorcontrib><creatorcontrib>Silverman, E.J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Boskiner, J.</au><au>Silverman, E.J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Arc detection for telephone DC power distribution systems</atitle><btitle>Proceedings of Intelec 93: 15th International Telecommunications Energy Conference</btitle><stitle>INTLEC</stitle><date>1993</date><risdate>1993</risdate><volume>2</volume><spage>341</spage><epage>344 vol.2</epage><pages>341-344 vol.2</pages><isbn>0780318420</isbn><isbn>9780780318427</isbn><abstract>Arcing faults may occur in DC power distribution systems in telephone offices. Fuses and circuit breakers are not intended to protect against arcing faults. Therefore, the detection of arcing faults is a prime concern to help prevent fire ignition and the resulting damage caused by fire and its by-products. This paper describes a method to help detect arcing faults in telephone offices. It includes the work determining arc signatures and noise spectra in working, nonarcing, DC power distribution systems. Also, field and laboratory experiments investigating the performance of an experimental prototype arc detection system are described. Possible applications of an arc detection system are included.&lt; &gt;</abstract><pub>IEEE</pub><doi>10.1109/INTLEC.1993.388549</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 0780318420
ispartof Proceedings of Intelec 93: 15th International Telecommunications Energy Conference, 1993, Vol.2, p.341-344 vol.2
issn
language eng
recordid cdi_ieee_primary_388549
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Circuit breakers
Circuit faults
Electrical fault detection
Fault detection
Fires
Fuses
Ignition
Power distribution
Power system protection
Telephony
title Arc detection for telephone DC power distribution systems
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T02%3A27%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Arc%20detection%20for%20telephone%20DC%20power%20distribution%20systems&rft.btitle=Proceedings%20of%20Intelec%2093:%2015th%20International%20Telecommunications%20Energy%20Conference&rft.au=Boskiner,%20J.&rft.date=1993&rft.volume=2&rft.spage=341&rft.epage=344%20vol.2&rft.pages=341-344%20vol.2&rft.isbn=0780318420&rft.isbn_list=9780780318427&rft_id=info:doi/10.1109/INTLEC.1993.388549&rft_dat=%3Cieee_6IE%3E388549%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=388549&rfr_iscdi=true