Measurements of Loma Linda proton therapy gantry dipoles
We describe the procedures used by the Fermilab Magnet Test Facility (MTF) to perform tests of dipoles to be installed in the beam lines of the Loma Linda University Medical Center Proton Therapy Facility. The dipoles were manufactured in two styles, one style having a 45/spl deg/ bending angle and...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2858 vol.4 |
---|---|
container_issue | |
container_start_page | 2856 |
container_title | |
container_volume | |
creator | Glass, H.D. Mazur, P.O. Sim, J.W. |
description | We describe the procedures used by the Fermilab Magnet Test Facility (MTF) to perform tests of dipoles to be installed in the beam lines of the Loma Linda University Medical Center Proton Therapy Facility. The dipoles were manufactured in two styles, one style having a 45/spl deg/ bending angle and the other a 135/spl deg/ bending angle. The tests included magnetic field measurements using a Hall probe and the measurement of coil temperatures, voltages, and water flow rates. The probe was mounted on a movable cart which could be wheeled along the magnet beam pipe; we mounted extensions onto each end of the beam pipe to allow for the probe to measure the magnet end fields. The probe was also mounted at varying transverse positions on the cart to allow for field shape measurements, from which body quadrupole and sextupole coefficients were determined. A longitudinal sampling of the field down the entire length of the magnet allowed us to measure the total integrated field of each magnet. Hall probe measurements were controlled by a C program running on a Unix workstation.< > |
doi_str_mv | 10.1109/PAC.1993.309484 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_309484</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>309484</ieee_id><sourcerecordid>309484</sourcerecordid><originalsourceid>FETCH-LOGICAL-i213t-843fb619a29ae86b0c2cdfb1fdeee2bc3ce92aa90c5e46be1469c6385372f5193</originalsourceid><addsrcrecordid>eNotj0tLxDAUhQMiKGPXgqv8gdYkt83kLofiCyq60PVwm95oZfogqYv-ewvj4cC3Oh8cIW61KrRWeP9-qAuNCAUoLF15ITLcO7UVtFFgr0SW0o_aUlXOWnUt3CtT-o088LgkOQXZTAPJph87knOclmmUyzdHmlf5ReMSV9n183TidCMuA50SZ__cic_Hh4_6OW_enl7qQ5P3RsOSuxJCazWSQWJnW-WN70KrQ8fMpvXgGQ0RKl9xaVvWpUVvwVWwN6HSCDtxd_b22-A4x36guB7P9-APeKFFew</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Measurements of Loma Linda proton therapy gantry dipoles</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Glass, H.D. ; Mazur, P.O. ; Sim, J.W.</creator><creatorcontrib>Glass, H.D. ; Mazur, P.O. ; Sim, J.W.</creatorcontrib><description>We describe the procedures used by the Fermilab Magnet Test Facility (MTF) to perform tests of dipoles to be installed in the beam lines of the Loma Linda University Medical Center Proton Therapy Facility. The dipoles were manufactured in two styles, one style having a 45/spl deg/ bending angle and the other a 135/spl deg/ bending angle. The tests included magnetic field measurements using a Hall probe and the measurement of coil temperatures, voltages, and water flow rates. The probe was mounted on a movable cart which could be wheeled along the magnet beam pipe; we mounted extensions onto each end of the beam pipe to allow for the probe to measure the magnet end fields. The probe was also mounted at varying transverse positions on the cart to allow for field shape measurements, from which body quadrupole and sextupole coefficients were determined. A longitudinal sampling of the field down the entire length of the magnet allowed us to measure the total integrated field of each magnet. Hall probe measurements were controlled by a C program running on a Unix workstation.< ></description><identifier>ISBN: 9780780312036</identifier><identifier>ISBN: 0780312031</identifier><identifier>DOI: 10.1109/PAC.1993.309484</identifier><language>eng</language><publisher>IEEE</publisher><subject>Hall effect devices ; Magnetic field measurement ; Medical tests ; Medical treatment ; Particle beams ; Performance evaluation ; Probes ; Protons ; Temperature measurement ; Test facilities</subject><ispartof>Proceedings of International Conference on Particle Accelerators, 1993, p.2856-2858 vol.4</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/309484$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/309484$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Glass, H.D.</creatorcontrib><creatorcontrib>Mazur, P.O.</creatorcontrib><creatorcontrib>Sim, J.W.</creatorcontrib><title>Measurements of Loma Linda proton therapy gantry dipoles</title><title>Proceedings of International Conference on Particle Accelerators</title><addtitle>PAC</addtitle><description>We describe the procedures used by the Fermilab Magnet Test Facility (MTF) to perform tests of dipoles to be installed in the beam lines of the Loma Linda University Medical Center Proton Therapy Facility. The dipoles were manufactured in two styles, one style having a 45/spl deg/ bending angle and the other a 135/spl deg/ bending angle. The tests included magnetic field measurements using a Hall probe and the measurement of coil temperatures, voltages, and water flow rates. The probe was mounted on a movable cart which could be wheeled along the magnet beam pipe; we mounted extensions onto each end of the beam pipe to allow for the probe to measure the magnet end fields. The probe was also mounted at varying transverse positions on the cart to allow for field shape measurements, from which body quadrupole and sextupole coefficients were determined. A longitudinal sampling of the field down the entire length of the magnet allowed us to measure the total integrated field of each magnet. Hall probe measurements were controlled by a C program running on a Unix workstation.< ></description><subject>Hall effect devices</subject><subject>Magnetic field measurement</subject><subject>Medical tests</subject><subject>Medical treatment</subject><subject>Particle beams</subject><subject>Performance evaluation</subject><subject>Probes</subject><subject>Protons</subject><subject>Temperature measurement</subject><subject>Test facilities</subject><isbn>9780780312036</isbn><isbn>0780312031</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1993</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj0tLxDAUhQMiKGPXgqv8gdYkt83kLofiCyq60PVwm95oZfogqYv-ewvj4cC3Oh8cIW61KrRWeP9-qAuNCAUoLF15ITLcO7UVtFFgr0SW0o_aUlXOWnUt3CtT-o088LgkOQXZTAPJph87knOclmmUyzdHmlf5ReMSV9n183TidCMuA50SZ__cic_Hh4_6OW_enl7qQ5P3RsOSuxJCazWSQWJnW-WN70KrQ8fMpvXgGQ0RKl9xaVvWpUVvwVWwN6HSCDtxd_b22-A4x36guB7P9-APeKFFew</recordid><startdate>1993</startdate><enddate>1993</enddate><creator>Glass, H.D.</creator><creator>Mazur, P.O.</creator><creator>Sim, J.W.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>1993</creationdate><title>Measurements of Loma Linda proton therapy gantry dipoles</title><author>Glass, H.D. ; Mazur, P.O. ; Sim, J.W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i213t-843fb619a29ae86b0c2cdfb1fdeee2bc3ce92aa90c5e46be1469c6385372f5193</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Hall effect devices</topic><topic>Magnetic field measurement</topic><topic>Medical tests</topic><topic>Medical treatment</topic><topic>Particle beams</topic><topic>Performance evaluation</topic><topic>Probes</topic><topic>Protons</topic><topic>Temperature measurement</topic><topic>Test facilities</topic><toplevel>online_resources</toplevel><creatorcontrib>Glass, H.D.</creatorcontrib><creatorcontrib>Mazur, P.O.</creatorcontrib><creatorcontrib>Sim, J.W.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Glass, H.D.</au><au>Mazur, P.O.</au><au>Sim, J.W.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Measurements of Loma Linda proton therapy gantry dipoles</atitle><btitle>Proceedings of International Conference on Particle Accelerators</btitle><stitle>PAC</stitle><date>1993</date><risdate>1993</risdate><spage>2856</spage><epage>2858 vol.4</epage><pages>2856-2858 vol.4</pages><isbn>9780780312036</isbn><isbn>0780312031</isbn><abstract>We describe the procedures used by the Fermilab Magnet Test Facility (MTF) to perform tests of dipoles to be installed in the beam lines of the Loma Linda University Medical Center Proton Therapy Facility. The dipoles were manufactured in two styles, one style having a 45/spl deg/ bending angle and the other a 135/spl deg/ bending angle. The tests included magnetic field measurements using a Hall probe and the measurement of coil temperatures, voltages, and water flow rates. The probe was mounted on a movable cart which could be wheeled along the magnet beam pipe; we mounted extensions onto each end of the beam pipe to allow for the probe to measure the magnet end fields. The probe was also mounted at varying transverse positions on the cart to allow for field shape measurements, from which body quadrupole and sextupole coefficients were determined. A longitudinal sampling of the field down the entire length of the magnet allowed us to measure the total integrated field of each magnet. Hall probe measurements were controlled by a C program running on a Unix workstation.< ></abstract><pub>IEEE</pub><doi>10.1109/PAC.1993.309484</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9780780312036 |
ispartof | Proceedings of International Conference on Particle Accelerators, 1993, p.2856-2858 vol.4 |
issn | |
language | eng |
recordid | cdi_ieee_primary_309484 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Hall effect devices Magnetic field measurement Medical tests Medical treatment Particle beams Performance evaluation Probes Protons Temperature measurement Test facilities |
title | Measurements of Loma Linda proton therapy gantry dipoles |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T17%3A49%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Measurements%20of%20Loma%20Linda%20proton%20therapy%20gantry%20dipoles&rft.btitle=Proceedings%20of%20International%20Conference%20on%20Particle%20Accelerators&rft.au=Glass,%20H.D.&rft.date=1993&rft.spage=2856&rft.epage=2858%20vol.4&rft.pages=2856-2858%20vol.4&rft.isbn=9780780312036&rft.isbn_list=0780312031&rft_id=info:doi/10.1109/PAC.1993.309484&rft_dat=%3Cieee_6IE%3E309484%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=309484&rfr_iscdi=true |