Partial discharge measurements and pulsed resonant wave excitation

A transient technique, referred to as the pulsed resonant wave technique, for in situ testing of extruded polymeric cable is discussed. A small, cost-effective power supply is used for energizing large capacitance specimens. This power supply has many of the benefits of testing at power line frequen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Steiner, J.P., Ward, B.H.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 392
container_issue
container_start_page 389
container_title
container_volume
creator Steiner, J.P.
Ward, B.H.
description A transient technique, referred to as the pulsed resonant wave technique, for in situ testing of extruded polymeric cable is discussed. A small, cost-effective power supply is used for energizing large capacitance specimens. This power supply has many of the benefits of testing at power line frequencies and none of the drawbacks of the other current methods, which are discussed for comparison. A digital noise reduction technique that mitigates the effects of interference is also used.< >
doi_str_mv 10.1109/ELINSL.1992.246982
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_246982</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>246982</ieee_id><sourcerecordid>246982</sourcerecordid><originalsourceid>FETCH-LOGICAL-i174t-bba202d2f4970dcbfecfbf09612668267805a1d84c9e686a79bf7a2d26464eb73</originalsourceid><addsrcrecordid>eNotT81KAzEYDKhgqfsCPeUFdk2yaX6OWqoWFhVU8Fa-bL5opN2WJFX79i7UYWAuM8MMITPOGs6ZvV52q8eXruHWikZIZY04I5XVho1smZK2PScTzoytmZHvl6TK-YuNkHNmOZ-Q22dIJcKG-pj7T0gfSLcI-ZBwi0PJFAZP94dNRk8T5t0AQ6E_8I0Uf_tYoMTdcEUuAoyO6l-n5O1u-bp4qLun-9Xipqsj17LUzoFgwosgrWa-dwH74AKziguljFDj4Dlwb2RvURkF2rqgYQwoqSQ63U7J7NQbEXG9T3EL6bg-nW7_ABgvTD8</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Partial discharge measurements and pulsed resonant wave excitation</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Steiner, J.P. ; Ward, B.H.</creator><creatorcontrib>Steiner, J.P. ; Ward, B.H.</creatorcontrib><description>A transient technique, referred to as the pulsed resonant wave technique, for in situ testing of extruded polymeric cable is discussed. A small, cost-effective power supply is used for energizing large capacitance specimens. This power supply has many of the benefits of testing at power line frequencies and none of the drawbacks of the other current methods, which are discussed for comparison. A digital noise reduction technique that mitigates the effects of interference is also used.&lt; &gt;</description><identifier>ISSN: 1089-084X</identifier><identifier>ISBN: 9780780306493</identifier><identifier>ISBN: 078030649X</identifier><identifier>DOI: 10.1109/ELINSL.1992.246982</identifier><language>eng</language><publisher>IEEE</publisher><subject>Capacitance ; Frequency ; Noise reduction ; Partial discharge measurement ; Polymers ; Power supplies ; Pulse measurements ; Pulsed power supplies ; Resonance ; Testing</subject><ispartof>Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, 1992, p.389-392</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/246982$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,4036,4037,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/246982$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Steiner, J.P.</creatorcontrib><creatorcontrib>Ward, B.H.</creatorcontrib><title>Partial discharge measurements and pulsed resonant wave excitation</title><title>Conference Record of the 1992 IEEE International Symposium on Electrical Insulation</title><addtitle>ELINSL</addtitle><description>A transient technique, referred to as the pulsed resonant wave technique, for in situ testing of extruded polymeric cable is discussed. A small, cost-effective power supply is used for energizing large capacitance specimens. This power supply has many of the benefits of testing at power line frequencies and none of the drawbacks of the other current methods, which are discussed for comparison. A digital noise reduction technique that mitigates the effects of interference is also used.&lt; &gt;</description><subject>Capacitance</subject><subject>Frequency</subject><subject>Noise reduction</subject><subject>Partial discharge measurement</subject><subject>Polymers</subject><subject>Power supplies</subject><subject>Pulse measurements</subject><subject>Pulsed power supplies</subject><subject>Resonance</subject><subject>Testing</subject><issn>1089-084X</issn><isbn>9780780306493</isbn><isbn>078030649X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1992</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotT81KAzEYDKhgqfsCPeUFdk2yaX6OWqoWFhVU8Fa-bL5opN2WJFX79i7UYWAuM8MMITPOGs6ZvV52q8eXruHWikZIZY04I5XVho1smZK2PScTzoytmZHvl6TK-YuNkHNmOZ-Q22dIJcKG-pj7T0gfSLcI-ZBwi0PJFAZP94dNRk8T5t0AQ6E_8I0Uf_tYoMTdcEUuAoyO6l-n5O1u-bp4qLun-9Xipqsj17LUzoFgwosgrWa-dwH74AKziguljFDj4Dlwb2RvURkF2rqgYQwoqSQ63U7J7NQbEXG9T3EL6bg-nW7_ABgvTD8</recordid><startdate>1992</startdate><enddate>1992</enddate><creator>Steiner, J.P.</creator><creator>Ward, B.H.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>1992</creationdate><title>Partial discharge measurements and pulsed resonant wave excitation</title><author>Steiner, J.P. ; Ward, B.H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i174t-bba202d2f4970dcbfecfbf09612668267805a1d84c9e686a79bf7a2d26464eb73</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Capacitance</topic><topic>Frequency</topic><topic>Noise reduction</topic><topic>Partial discharge measurement</topic><topic>Polymers</topic><topic>Power supplies</topic><topic>Pulse measurements</topic><topic>Pulsed power supplies</topic><topic>Resonance</topic><topic>Testing</topic><toplevel>online_resources</toplevel><creatorcontrib>Steiner, J.P.</creatorcontrib><creatorcontrib>Ward, B.H.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Steiner, J.P.</au><au>Ward, B.H.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Partial discharge measurements and pulsed resonant wave excitation</atitle><btitle>Conference Record of the 1992 IEEE International Symposium on Electrical Insulation</btitle><stitle>ELINSL</stitle><date>1992</date><risdate>1992</risdate><spage>389</spage><epage>392</epage><pages>389-392</pages><issn>1089-084X</issn><isbn>9780780306493</isbn><isbn>078030649X</isbn><abstract>A transient technique, referred to as the pulsed resonant wave technique, for in situ testing of extruded polymeric cable is discussed. A small, cost-effective power supply is used for energizing large capacitance specimens. This power supply has many of the benefits of testing at power line frequencies and none of the drawbacks of the other current methods, which are discussed for comparison. A digital noise reduction technique that mitigates the effects of interference is also used.&lt; &gt;</abstract><pub>IEEE</pub><doi>10.1109/ELINSL.1992.246982</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1089-084X
ispartof Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, 1992, p.389-392
issn 1089-084X
language eng
recordid cdi_ieee_primary_246982
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Capacitance
Frequency
Noise reduction
Partial discharge measurement
Polymers
Power supplies
Pulse measurements
Pulsed power supplies
Resonance
Testing
title Partial discharge measurements and pulsed resonant wave excitation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T00%3A03%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Partial%20discharge%20measurements%20and%20pulsed%20resonant%20wave%20excitation&rft.btitle=Conference%20Record%20of%20the%201992%20IEEE%20International%20Symposium%20on%20Electrical%20Insulation&rft.au=Steiner,%20J.P.&rft.date=1992&rft.spage=389&rft.epage=392&rft.pages=389-392&rft.issn=1089-084X&rft.isbn=9780780306493&rft.isbn_list=078030649X&rft_id=info:doi/10.1109/ELINSL.1992.246982&rft_dat=%3Cieee_6IE%3E246982%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=246982&rfr_iscdi=true