Real-Time System for Dosimetry in IORT (Intra Operative Radiation Therapy)

Intra Operative Radiation Therapy (IORT) is a technique based on delivery of a high dose of ionising radiation to the cancer tissue, after tumour ablation, during surgery, while reducing the exposure of normal surrounding tissue. The Novac7 is a new linear accelerator expressly conceived to perform...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2006-10, Vol.53 (5), p.2844-2848
Hauptverfasser: Brancaccio, R., Bettuzzi, M., Casali, F., Cornacchia, S., Morigi, M., Pasini, A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2848
container_issue 5
container_start_page 2844
container_title IEEE transactions on nuclear science
container_volume 53
creator Brancaccio, R.
Bettuzzi, M.
Casali, F.
Cornacchia, S.
Morigi, M.
Pasini, A.
description Intra Operative Radiation Therapy (IORT) is a technique based on delivery of a high dose of ionising radiation to the cancer tissue, after tumour ablation, during surgery, while reducing the exposure of normal surrounding tissue. The Novac7 is a new linear accelerator expressly conceived to perform in the operating room. This accelerator supplies electron beams with high dose rate. Because these peculiar characteristics, classical dosimetric techniques are not able to give at once a real-time response and an extensive measure of the absorbed dose. The new system is composed by a grid of scintillating optical fibres coupled with two arrays of photodiodes. The instrument samples the delivered beam at 100 Hz. The dedicated software collects the two projection-signals and reconstructs the bi-dimensional image. Moreover it provides a series of dosimetric parameters. We studied an appropriate reconstruction algorithm searching the best compromise between the computational complexity and an high precision. An accelerator having energies ranging from 3 to 12 MeV has been used for the tests. The system is able to give a real time response (within 30 seconds), the resolution is of 1 millimeter. The response is linear versus dose and the measures are not affected by the high dose rate. The conclusions confirm the capability of the instrument to overcome problems encountered with classic dosimetry, showing that the results obtained strongly encourage the continuation of this research
doi_str_mv 10.1109/TNS.2006.882498
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_ieee_primary_1710283</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1710283</ieee_id><sourcerecordid>889382669</sourcerecordid><originalsourceid>FETCH-LOGICAL-c320t-4d48164685dae5157f0a0749eb1ff1b8fe95f9fa145aead9804c78d0232238ee3</originalsourceid><addsrcrecordid>eNpdkMtLw0AQxhdRsFbPHrwsXtRD2n0l2T1KfVWKhTael20yiyl5uZsK-e9diSAIAzPz8Zvh40PokpIZpUTNs7ftjBGSzKRkQskjNKFxLCMap_IYTQihMlJCqVN05v0-rCIm8QS9bsBUUVbWgLeD76HGtnX4ofVB6d2AywYv15sM3y6b3hm87sCZvvwCvDFFGaa2wdlH0Lrh7hydWFN5uPjtU_T-9JgtXqLV-nm5uF9FOWekj0QhJE1EIuPCQBzsWWJIKhTsqLV0Jy2o2CprgkEDplCSiDyVBWGcMS4B-BTdjH87134ewPe6Ln0OVWUaaA9eS6m4ZEmiAnn9j9y3B9cEc1pRRkMJHqD5COWu9d6B1Z0ra-MGTYn-SVaHZPVPsnpMNlxcjRclAPzRKSVMcv4Ngh5ymg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>912112143</pqid></control><display><type>article</type><title>Real-Time System for Dosimetry in IORT (Intra Operative Radiation Therapy)</title><source>IEEE Electronic Library (IEL)</source><creator>Brancaccio, R. ; Bettuzzi, M. ; Casali, F. ; Cornacchia, S. ; Morigi, M. ; Pasini, A.</creator><creatorcontrib>Brancaccio, R. ; Bettuzzi, M. ; Casali, F. ; Cornacchia, S. ; Morigi, M. ; Pasini, A.</creatorcontrib><description>Intra Operative Radiation Therapy (IORT) is a technique based on delivery of a high dose of ionising radiation to the cancer tissue, after tumour ablation, during surgery, while reducing the exposure of normal surrounding tissue. The Novac7 is a new linear accelerator expressly conceived to perform in the operating room. This accelerator supplies electron beams with high dose rate. Because these peculiar characteristics, classical dosimetric techniques are not able to give at once a real-time response and an extensive measure of the absorbed dose. The new system is composed by a grid of scintillating optical fibres coupled with two arrays of photodiodes. The instrument samples the delivered beam at 100 Hz. The dedicated software collects the two projection-signals and reconstructs the bi-dimensional image. Moreover it provides a series of dosimetric parameters. We studied an appropriate reconstruction algorithm searching the best compromise between the computational complexity and an high precision. An accelerator having energies ranging from 3 to 12 MeV has been used for the tests. The system is able to give a real time response (within 30 seconds), the resolution is of 1 millimeter. The response is linear versus dose and the measures are not affected by the high dose rate. The conclusions confirm the capability of the instrument to overcome problems encountered with classic dosimetry, showing that the results obtained strongly encourage the continuation of this research</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.2006.882498</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Accelerators ; Biomedical applications of radiation ; Cancer ; Digital system ; Dosage ; Dosimeters ; Dosimetry ; electron beam ; FOS ; Instruments ; Intra Operative Radiation Therapy (IORT) ; Ionizing radiation ; Linear accelerators ; Oncological surgery ; Optical arrays ; photodiode array ; Radiation therapy ; Real time ; Real time systems ; real-time acquisition ; Searching ; Studies ; Tumors</subject><ispartof>IEEE transactions on nuclear science, 2006-10, Vol.53 (5), p.2844-2848</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2006</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c320t-4d48164685dae5157f0a0749eb1ff1b8fe95f9fa145aead9804c78d0232238ee3</citedby><cites>FETCH-LOGICAL-c320t-4d48164685dae5157f0a0749eb1ff1b8fe95f9fa145aead9804c78d0232238ee3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1710283$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27923,27924,54757</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1710283$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Brancaccio, R.</creatorcontrib><creatorcontrib>Bettuzzi, M.</creatorcontrib><creatorcontrib>Casali, F.</creatorcontrib><creatorcontrib>Cornacchia, S.</creatorcontrib><creatorcontrib>Morigi, M.</creatorcontrib><creatorcontrib>Pasini, A.</creatorcontrib><title>Real-Time System for Dosimetry in IORT (Intra Operative Radiation Therapy)</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>Intra Operative Radiation Therapy (IORT) is a technique based on delivery of a high dose of ionising radiation to the cancer tissue, after tumour ablation, during surgery, while reducing the exposure of normal surrounding tissue. The Novac7 is a new linear accelerator expressly conceived to perform in the operating room. This accelerator supplies electron beams with high dose rate. Because these peculiar characteristics, classical dosimetric techniques are not able to give at once a real-time response and an extensive measure of the absorbed dose. The new system is composed by a grid of scintillating optical fibres coupled with two arrays of photodiodes. The instrument samples the delivered beam at 100 Hz. The dedicated software collects the two projection-signals and reconstructs the bi-dimensional image. Moreover it provides a series of dosimetric parameters. We studied an appropriate reconstruction algorithm searching the best compromise between the computational complexity and an high precision. An accelerator having energies ranging from 3 to 12 MeV has been used for the tests. The system is able to give a real time response (within 30 seconds), the resolution is of 1 millimeter. The response is linear versus dose and the measures are not affected by the high dose rate. The conclusions confirm the capability of the instrument to overcome problems encountered with classic dosimetry, showing that the results obtained strongly encourage the continuation of this research</description><subject>Accelerators</subject><subject>Biomedical applications of radiation</subject><subject>Cancer</subject><subject>Digital system</subject><subject>Dosage</subject><subject>Dosimeters</subject><subject>Dosimetry</subject><subject>electron beam</subject><subject>FOS</subject><subject>Instruments</subject><subject>Intra Operative Radiation Therapy (IORT)</subject><subject>Ionizing radiation</subject><subject>Linear accelerators</subject><subject>Oncological surgery</subject><subject>Optical arrays</subject><subject>photodiode array</subject><subject>Radiation therapy</subject><subject>Real time</subject><subject>Real time systems</subject><subject>real-time acquisition</subject><subject>Searching</subject><subject>Studies</subject><subject>Tumors</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpdkMtLw0AQxhdRsFbPHrwsXtRD2n0l2T1KfVWKhTael20yiyl5uZsK-e9diSAIAzPz8Zvh40PokpIZpUTNs7ftjBGSzKRkQskjNKFxLCMap_IYTQihMlJCqVN05v0-rCIm8QS9bsBUUVbWgLeD76HGtnX4ofVB6d2AywYv15sM3y6b3hm87sCZvvwCvDFFGaa2wdlH0Lrh7hydWFN5uPjtU_T-9JgtXqLV-nm5uF9FOWekj0QhJE1EIuPCQBzsWWJIKhTsqLV0Jy2o2CprgkEDplCSiDyVBWGcMS4B-BTdjH87134ewPe6Ln0OVWUaaA9eS6m4ZEmiAnn9j9y3B9cEc1pRRkMJHqD5COWu9d6B1Z0ra-MGTYn-SVaHZPVPsnpMNlxcjRclAPzRKSVMcv4Ngh5ymg</recordid><startdate>20061001</startdate><enddate>20061001</enddate><creator>Brancaccio, R.</creator><creator>Bettuzzi, M.</creator><creator>Casali, F.</creator><creator>Cornacchia, S.</creator><creator>Morigi, M.</creator><creator>Pasini, A.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QL</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7T7</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>M7N</scope><scope>P64</scope></search><sort><creationdate>20061001</creationdate><title>Real-Time System for Dosimetry in IORT (Intra Operative Radiation Therapy)</title><author>Brancaccio, R. ; Bettuzzi, M. ; Casali, F. ; Cornacchia, S. ; Morigi, M. ; Pasini, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c320t-4d48164685dae5157f0a0749eb1ff1b8fe95f9fa145aead9804c78d0232238ee3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Accelerators</topic><topic>Biomedical applications of radiation</topic><topic>Cancer</topic><topic>Digital system</topic><topic>Dosage</topic><topic>Dosimeters</topic><topic>Dosimetry</topic><topic>electron beam</topic><topic>FOS</topic><topic>Instruments</topic><topic>Intra Operative Radiation Therapy (IORT)</topic><topic>Ionizing radiation</topic><topic>Linear accelerators</topic><topic>Oncological surgery</topic><topic>Optical arrays</topic><topic>photodiode array</topic><topic>Radiation therapy</topic><topic>Real time</topic><topic>Real time systems</topic><topic>real-time acquisition</topic><topic>Searching</topic><topic>Studies</topic><topic>Tumors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Brancaccio, R.</creatorcontrib><creatorcontrib>Bettuzzi, M.</creatorcontrib><creatorcontrib>Casali, F.</creatorcontrib><creatorcontrib>Cornacchia, S.</creatorcontrib><creatorcontrib>Morigi, M.</creatorcontrib><creatorcontrib>Pasini, A.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Brancaccio, R.</au><au>Bettuzzi, M.</au><au>Casali, F.</au><au>Cornacchia, S.</au><au>Morigi, M.</au><au>Pasini, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Real-Time System for Dosimetry in IORT (Intra Operative Radiation Therapy)</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>2006-10-01</date><risdate>2006</risdate><volume>53</volume><issue>5</issue><spage>2844</spage><epage>2848</epage><pages>2844-2848</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>Intra Operative Radiation Therapy (IORT) is a technique based on delivery of a high dose of ionising radiation to the cancer tissue, after tumour ablation, during surgery, while reducing the exposure of normal surrounding tissue. The Novac7 is a new linear accelerator expressly conceived to perform in the operating room. This accelerator supplies electron beams with high dose rate. Because these peculiar characteristics, classical dosimetric techniques are not able to give at once a real-time response and an extensive measure of the absorbed dose. The new system is composed by a grid of scintillating optical fibres coupled with two arrays of photodiodes. The instrument samples the delivered beam at 100 Hz. The dedicated software collects the two projection-signals and reconstructs the bi-dimensional image. Moreover it provides a series of dosimetric parameters. We studied an appropriate reconstruction algorithm searching the best compromise between the computational complexity and an high precision. An accelerator having energies ranging from 3 to 12 MeV has been used for the tests. The system is able to give a real time response (within 30 seconds), the resolution is of 1 millimeter. The response is linear versus dose and the measures are not affected by the high dose rate. The conclusions confirm the capability of the instrument to overcome problems encountered with classic dosimetry, showing that the results obtained strongly encourage the continuation of this research</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TNS.2006.882498</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 2006-10, Vol.53 (5), p.2844-2848
issn 0018-9499
1558-1578
language eng
recordid cdi_ieee_primary_1710283
source IEEE Electronic Library (IEL)
subjects Accelerators
Biomedical applications of radiation
Cancer
Digital system
Dosage
Dosimeters
Dosimetry
electron beam
FOS
Instruments
Intra Operative Radiation Therapy (IORT)
Ionizing radiation
Linear accelerators
Oncological surgery
Optical arrays
photodiode array
Radiation therapy
Real time
Real time systems
real-time acquisition
Searching
Studies
Tumors
title Real-Time System for Dosimetry in IORT (Intra Operative Radiation Therapy)
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T20%3A42%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Real-Time%20System%20for%20Dosimetry%20in%20IORT%20(Intra%20Operative%20Radiation%20Therapy)&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Brancaccio,%20R.&rft.date=2006-10-01&rft.volume=53&rft.issue=5&rft.spage=2844&rft.epage=2848&rft.pages=2844-2848&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.2006.882498&rft_dat=%3Cproquest_RIE%3E889382669%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=912112143&rft_id=info:pmid/&rft_ieee_id=1710283&rfr_iscdi=true