Using of the millimeter wave dielectrometer for study of liquid helium dynamic characteristics

The WGM method was used in designed cryogenic dielectrometer for measurement of dielectric parameters of cryogenic liquids with small losses within the frequency range of 50-150 GHz and temperatures 0.8-300 K. The change of resonant characteristics of high-Q DDR, placed into He 4 at temperature lowe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Derkach, V.N., Golovashchenko, R.V., Nedukh, S.V., Plevako, O.S., Tarapov, S.I.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 837 Vol. 2
container_issue
container_start_page 836
container_title
container_volume 2
creator Derkach, V.N.
Golovashchenko, R.V.
Nedukh, S.V.
Plevako, O.S.
Tarapov, S.I.
description The WGM method was used in designed cryogenic dielectrometer for measurement of dielectric parameters of cryogenic liquids with small losses within the frequency range of 50-150 GHz and temperatures 0.8-300 K. The change of resonant characteristics of high-Q DDR, placed into He 4 at temperature lower the lambda-transition (a superfluid state) is detected
doi_str_mv 10.1109/CRMICO.2005.1565162
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1565162</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1565162</ieee_id><sourcerecordid>1565162</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-68c217d9b6e7d0886189313f6a13c7cf513ee5a3af27cba91da04eaac6cf25253</originalsourceid><addsrcrecordid>eNotkF1LwzAUhgMiqHO_YDf5A61Js6TJpRQ_BpOBzFvHWXJij7SrNq3Sf69ju3rg5eG9eBhbSJFLKdxd9fqyqjZ5IYTOpTZamuKC3ThjSmesFcsrNk_pUwghnSmV1dfs_S3R4YN3kQ818paahlocsOe_8IM8EDboh747bbHreRrGMB39hr5HCrzGhsaWh-kALXnua-jB_8uUBvLpll1GaBLOz5yx7ePDtnrO1punVXW_zsiJITPWF7IMbm-wDMJaI61TUkUDUvnSRy0VogYFsSj9HpwMIJYI4I2PhS60mrHF6ZYQcffVUwv9tDsXUH9131Rb</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Using of the millimeter wave dielectrometer for study of liquid helium dynamic characteristics</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Derkach, V.N. ; Golovashchenko, R.V. ; Nedukh, S.V. ; Plevako, O.S. ; Tarapov, S.I.</creator><creatorcontrib>Derkach, V.N. ; Golovashchenko, R.V. ; Nedukh, S.V. ; Plevako, O.S. ; Tarapov, S.I.</creatorcontrib><description>The WGM method was used in designed cryogenic dielectrometer for measurement of dielectric parameters of cryogenic liquids with small losses within the frequency range of 50-150 GHz and temperatures 0.8-300 K. The change of resonant characteristics of high-Q DDR, placed into He 4 at temperature lower the lambda-transition (a superfluid state) is detected</description><identifier>ISBN: 9667968804</identifier><identifier>ISBN: 9789667968809</identifier><identifier>DOI: 10.1109/CRMICO.2005.1565162</identifier><language>eng</language><publisher>IEEE</publisher><subject>Cryogenics ; Dielectric liquids ; Dielectric loss measurement ; Dielectric measurements ; Frequency measurement ; Helium ; Loss measurement ; Millimeter wave measurements ; Millimeter wave technology ; Temperature distribution</subject><ispartof>2005 15th International Crimean Conference Microwave &amp; Telecommunication Technology, 2005, Vol.2, p.836-837 Vol. 2</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1565162$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,4036,4037,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1565162$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Derkach, V.N.</creatorcontrib><creatorcontrib>Golovashchenko, R.V.</creatorcontrib><creatorcontrib>Nedukh, S.V.</creatorcontrib><creatorcontrib>Plevako, O.S.</creatorcontrib><creatorcontrib>Tarapov, S.I.</creatorcontrib><title>Using of the millimeter wave dielectrometer for study of liquid helium dynamic characteristics</title><title>2005 15th International Crimean Conference Microwave &amp; Telecommunication Technology</title><addtitle>CRMICO</addtitle><description>The WGM method was used in designed cryogenic dielectrometer for measurement of dielectric parameters of cryogenic liquids with small losses within the frequency range of 50-150 GHz and temperatures 0.8-300 K. The change of resonant characteristics of high-Q DDR, placed into He 4 at temperature lower the lambda-transition (a superfluid state) is detected</description><subject>Cryogenics</subject><subject>Dielectric liquids</subject><subject>Dielectric loss measurement</subject><subject>Dielectric measurements</subject><subject>Frequency measurement</subject><subject>Helium</subject><subject>Loss measurement</subject><subject>Millimeter wave measurements</subject><subject>Millimeter wave technology</subject><subject>Temperature distribution</subject><isbn>9667968804</isbn><isbn>9789667968809</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2005</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkF1LwzAUhgMiqHO_YDf5A61Js6TJpRQ_BpOBzFvHWXJij7SrNq3Sf69ju3rg5eG9eBhbSJFLKdxd9fqyqjZ5IYTOpTZamuKC3ThjSmesFcsrNk_pUwghnSmV1dfs_S3R4YN3kQ818paahlocsOe_8IM8EDboh747bbHreRrGMB39hr5HCrzGhsaWh-kALXnua-jB_8uUBvLpll1GaBLOz5yx7ePDtnrO1punVXW_zsiJITPWF7IMbm-wDMJaI61TUkUDUvnSRy0VogYFsSj9HpwMIJYI4I2PhS60mrHF6ZYQcffVUwv9tDsXUH9131Rb</recordid><startdate>2005</startdate><enddate>2005</enddate><creator>Derkach, V.N.</creator><creator>Golovashchenko, R.V.</creator><creator>Nedukh, S.V.</creator><creator>Plevako, O.S.</creator><creator>Tarapov, S.I.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>2005</creationdate><title>Using of the millimeter wave dielectrometer for study of liquid helium dynamic characteristics</title><author>Derkach, V.N. ; Golovashchenko, R.V. ; Nedukh, S.V. ; Plevako, O.S. ; Tarapov, S.I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-68c217d9b6e7d0886189313f6a13c7cf513ee5a3af27cba91da04eaac6cf25253</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Cryogenics</topic><topic>Dielectric liquids</topic><topic>Dielectric loss measurement</topic><topic>Dielectric measurements</topic><topic>Frequency measurement</topic><topic>Helium</topic><topic>Loss measurement</topic><topic>Millimeter wave measurements</topic><topic>Millimeter wave technology</topic><topic>Temperature distribution</topic><toplevel>online_resources</toplevel><creatorcontrib>Derkach, V.N.</creatorcontrib><creatorcontrib>Golovashchenko, R.V.</creatorcontrib><creatorcontrib>Nedukh, S.V.</creatorcontrib><creatorcontrib>Plevako, O.S.</creatorcontrib><creatorcontrib>Tarapov, S.I.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Derkach, V.N.</au><au>Golovashchenko, R.V.</au><au>Nedukh, S.V.</au><au>Plevako, O.S.</au><au>Tarapov, S.I.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Using of the millimeter wave dielectrometer for study of liquid helium dynamic characteristics</atitle><btitle>2005 15th International Crimean Conference Microwave &amp; Telecommunication Technology</btitle><stitle>CRMICO</stitle><date>2005</date><risdate>2005</risdate><volume>2</volume><spage>836</spage><epage>837 Vol. 2</epage><pages>836-837 Vol. 2</pages><isbn>9667968804</isbn><isbn>9789667968809</isbn><abstract>The WGM method was used in designed cryogenic dielectrometer for measurement of dielectric parameters of cryogenic liquids with small losses within the frequency range of 50-150 GHz and temperatures 0.8-300 K. The change of resonant characteristics of high-Q DDR, placed into He 4 at temperature lower the lambda-transition (a superfluid state) is detected</abstract><pub>IEEE</pub><doi>10.1109/CRMICO.2005.1565162</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9667968804
ispartof 2005 15th International Crimean Conference Microwave & Telecommunication Technology, 2005, Vol.2, p.836-837 Vol. 2
issn
language eng
recordid cdi_ieee_primary_1565162
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Cryogenics
Dielectric liquids
Dielectric loss measurement
Dielectric measurements
Frequency measurement
Helium
Loss measurement
Millimeter wave measurements
Millimeter wave technology
Temperature distribution
title Using of the millimeter wave dielectrometer for study of liquid helium dynamic characteristics
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T10%3A09%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Using%20of%20the%20millimeter%20wave%20dielectrometer%20for%20study%20of%20liquid%20helium%20dynamic%20characteristics&rft.btitle=2005%2015th%20International%20Crimean%20Conference%20Microwave%20&%20Telecommunication%20Technology&rft.au=Derkach,%20V.N.&rft.date=2005&rft.volume=2&rft.spage=836&rft.epage=837%20Vol.%202&rft.pages=836-837%20Vol.%202&rft.isbn=9667968804&rft.isbn_list=9789667968809&rft_id=info:doi/10.1109/CRMICO.2005.1565162&rft_dat=%3Cieee_6IE%3E1565162%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1565162&rfr_iscdi=true