Characterization of a novel heart and respiratory rate sensor

Existing methods of electronic patient monitoring require tethering the patient to the device, which is not well tolerated. This study characterizes the performance of a novel sensor array and digital signal processing (DSP) algorithms that extract heart and respiratory rates. The sensor lies under...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Jacobs, J.L., Embree, P., Glei, M., Christensen, S., Sullivan, P.K.
Format: Tagungsbericht
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2226
container_issue
container_start_page 2223
container_title
container_volume 1
creator Jacobs, J.L.
Embree, P.
Glei, M.
Christensen, S.
Sullivan, P.K.
description Existing methods of electronic patient monitoring require tethering the patient to the device, which is not well tolerated. This study characterizes the performance of a novel sensor array and digital signal processing (DSP) algorithms that extract heart and respiratory rates. The sensor lies under the sheets on a hospital bed, and when the patient lies down, it detects pressure waves generated by the heart, and by the act of breathing. The algorithms identify these signals of interest, filtering out extraneous signals. Output of the algorithms was compared to output from ECG and transthoracic impedance, taken from the same subject, at the same time. Forty-four adult volunteers were recruited. The results demonstrated an average of mean differences for heart rate of 0.50 beats per minute, with a standard deviation of 0.51. The average of mean differences for respiratory rate was 0.39 with standard deviation of 0.55. These results suggest this noninvasive, non-restrictive method of measuring heart and respiratory rates may be a viable solution to the problem of decreased vigilance of patient condition faced on the in-patient wards. Future studies will characterize performance in ill populations, and examine alarm schemes that are both highly sensitive and specific for the target population.
doi_str_mv 10.1109/IEMBS.2004.1403648
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1403648</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1403648</ieee_id><sourcerecordid>1403648</sourcerecordid><originalsourceid>FETCH-LOGICAL-i866-e78c10b8d3907d4bc53018c693e962838a1a7051a7a02bbb8439b255a149db443</originalsourceid><addsrcrecordid>eNotT81KAzEYDIig1H0BveQFdv3ys9nk4EGXqoWKB3svX3a_0kjdlGQR6tMbscMww1yGGcZuBTRCgLtfLd-ePhoJoBuhQRltL1jlOguFymrl5BWrcv6EAuVKttfsod9jwmGmFH5wDnHicceRT_GbDnxPmGaO08gT5WNIOMd04sWIZ5pyTDfscoeHTNXZF2zzvNz0r_X6_WXVP67rYI2pqbODAG9H5aAbtR9aBcIOxilyRlplUWAHbREE6b3_m-pl26LQbvRaqwW7-68NRLQ9pvCF6bQ9f1S_dmdGeg</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Characterization of a novel heart and respiratory rate sensor</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Jacobs, J.L. ; Embree, P. ; Glei, M. ; Christensen, S. ; Sullivan, P.K.</creator><creatorcontrib>Jacobs, J.L. ; Embree, P. ; Glei, M. ; Christensen, S. ; Sullivan, P.K.</creatorcontrib><description>Existing methods of electronic patient monitoring require tethering the patient to the device, which is not well tolerated. This study characterizes the performance of a novel sensor array and digital signal processing (DSP) algorithms that extract heart and respiratory rates. The sensor lies under the sheets on a hospital bed, and when the patient lies down, it detects pressure waves generated by the heart, and by the act of breathing. The algorithms identify these signals of interest, filtering out extraneous signals. Output of the algorithms was compared to output from ECG and transthoracic impedance, taken from the same subject, at the same time. Forty-four adult volunteers were recruited. The results demonstrated an average of mean differences for heart rate of 0.50 beats per minute, with a standard deviation of 0.51. The average of mean differences for respiratory rate was 0.39 with standard deviation of 0.55. These results suggest this noninvasive, non-restrictive method of measuring heart and respiratory rates may be a viable solution to the problem of decreased vigilance of patient condition faced on the in-patient wards. Future studies will characterize performance in ill populations, and examine alarm schemes that are both highly sensitive and specific for the target population.</description><identifier>ISBN: 9780780384392</identifier><identifier>ISBN: 0780384393</identifier><identifier>DOI: 10.1109/IEMBS.2004.1403648</identifier><language>eng ; jpn</language><publisher>IEEE</publisher><subject>Digital signal processing ; Electrocardiography ; Filtering algorithms ; Heart ; Heart Rate ; Hospitals ; Monitor ; Patient monitoring ; Respiratory Rate ; Sensor ; Sensor arrays ; Sensor phenomena and characterization ; Signal processing ; Signal processing algorithms</subject><ispartof>The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2004, Vol.1, p.2223-2226</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1403648$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,4040,4041,27916,54911</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1403648$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Jacobs, J.L.</creatorcontrib><creatorcontrib>Embree, P.</creatorcontrib><creatorcontrib>Glei, M.</creatorcontrib><creatorcontrib>Christensen, S.</creatorcontrib><creatorcontrib>Sullivan, P.K.</creatorcontrib><title>Characterization of a novel heart and respiratory rate sensor</title><title>The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><description>Existing methods of electronic patient monitoring require tethering the patient to the device, which is not well tolerated. This study characterizes the performance of a novel sensor array and digital signal processing (DSP) algorithms that extract heart and respiratory rates. The sensor lies under the sheets on a hospital bed, and when the patient lies down, it detects pressure waves generated by the heart, and by the act of breathing. The algorithms identify these signals of interest, filtering out extraneous signals. Output of the algorithms was compared to output from ECG and transthoracic impedance, taken from the same subject, at the same time. Forty-four adult volunteers were recruited. The results demonstrated an average of mean differences for heart rate of 0.50 beats per minute, with a standard deviation of 0.51. The average of mean differences for respiratory rate was 0.39 with standard deviation of 0.55. These results suggest this noninvasive, non-restrictive method of measuring heart and respiratory rates may be a viable solution to the problem of decreased vigilance of patient condition faced on the in-patient wards. Future studies will characterize performance in ill populations, and examine alarm schemes that are both highly sensitive and specific for the target population.</description><subject>Digital signal processing</subject><subject>Electrocardiography</subject><subject>Filtering algorithms</subject><subject>Heart</subject><subject>Heart Rate</subject><subject>Hospitals</subject><subject>Monitor</subject><subject>Patient monitoring</subject><subject>Respiratory Rate</subject><subject>Sensor</subject><subject>Sensor arrays</subject><subject>Sensor phenomena and characterization</subject><subject>Signal processing</subject><subject>Signal processing algorithms</subject><isbn>9780780384392</isbn><isbn>0780384393</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2004</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotT81KAzEYDIig1H0BveQFdv3ys9nk4EGXqoWKB3svX3a_0kjdlGQR6tMbscMww1yGGcZuBTRCgLtfLd-ePhoJoBuhQRltL1jlOguFymrl5BWrcv6EAuVKttfsod9jwmGmFH5wDnHicceRT_GbDnxPmGaO08gT5WNIOMd04sWIZ5pyTDfscoeHTNXZF2zzvNz0r_X6_WXVP67rYI2pqbODAG9H5aAbtR9aBcIOxilyRlplUWAHbREE6b3_m-pl26LQbvRaqwW7-68NRLQ9pvCF6bQ9f1S_dmdGeg</recordid><startdate>2004</startdate><enddate>2004</enddate><creator>Jacobs, J.L.</creator><creator>Embree, P.</creator><creator>Glei, M.</creator><creator>Christensen, S.</creator><creator>Sullivan, P.K.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2004</creationdate><title>Characterization of a novel heart and respiratory rate sensor</title><author>Jacobs, J.L. ; Embree, P. ; Glei, M. ; Christensen, S. ; Sullivan, P.K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i866-e78c10b8d3907d4bc53018c693e962838a1a7051a7a02bbb8439b255a149db443</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng ; jpn</language><creationdate>2004</creationdate><topic>Digital signal processing</topic><topic>Electrocardiography</topic><topic>Filtering algorithms</topic><topic>Heart</topic><topic>Heart Rate</topic><topic>Hospitals</topic><topic>Monitor</topic><topic>Patient monitoring</topic><topic>Respiratory Rate</topic><topic>Sensor</topic><topic>Sensor arrays</topic><topic>Sensor phenomena and characterization</topic><topic>Signal processing</topic><topic>Signal processing algorithms</topic><toplevel>online_resources</toplevel><creatorcontrib>Jacobs, J.L.</creatorcontrib><creatorcontrib>Embree, P.</creatorcontrib><creatorcontrib>Glei, M.</creatorcontrib><creatorcontrib>Christensen, S.</creatorcontrib><creatorcontrib>Sullivan, P.K.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Jacobs, J.L.</au><au>Embree, P.</au><au>Glei, M.</au><au>Christensen, S.</au><au>Sullivan, P.K.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Characterization of a novel heart and respiratory rate sensor</atitle><btitle>The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</btitle><stitle>IEMBS</stitle><date>2004</date><risdate>2004</risdate><volume>1</volume><spage>2223</spage><epage>2226</epage><pages>2223-2226</pages><isbn>9780780384392</isbn><isbn>0780384393</isbn><abstract>Existing methods of electronic patient monitoring require tethering the patient to the device, which is not well tolerated. This study characterizes the performance of a novel sensor array and digital signal processing (DSP) algorithms that extract heart and respiratory rates. The sensor lies under the sheets on a hospital bed, and when the patient lies down, it detects pressure waves generated by the heart, and by the act of breathing. The algorithms identify these signals of interest, filtering out extraneous signals. Output of the algorithms was compared to output from ECG and transthoracic impedance, taken from the same subject, at the same time. Forty-four adult volunteers were recruited. The results demonstrated an average of mean differences for heart rate of 0.50 beats per minute, with a standard deviation of 0.51. The average of mean differences for respiratory rate was 0.39 with standard deviation of 0.55. These results suggest this noninvasive, non-restrictive method of measuring heart and respiratory rates may be a viable solution to the problem of decreased vigilance of patient condition faced on the in-patient wards. Future studies will characterize performance in ill populations, and examine alarm schemes that are both highly sensitive and specific for the target population.</abstract><pub>IEEE</pub><doi>10.1109/IEMBS.2004.1403648</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9780780384392
ispartof The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2004, Vol.1, p.2223-2226
issn
language eng ; jpn
recordid cdi_ieee_primary_1403648
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Digital signal processing
Electrocardiography
Filtering algorithms
Heart
Heart Rate
Hospitals
Monitor
Patient monitoring
Respiratory Rate
Sensor
Sensor arrays
Sensor phenomena and characterization
Signal processing
Signal processing algorithms
title Characterization of a novel heart and respiratory rate sensor
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T07%3A46%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Characterization%20of%20a%20novel%20heart%20and%20respiratory%20rate%20sensor&rft.btitle=The%2026th%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Jacobs,%20J.L.&rft.date=2004&rft.volume=1&rft.spage=2223&rft.epage=2226&rft.pages=2223-2226&rft.isbn=9780780384392&rft.isbn_list=0780384393&rft_id=info:doi/10.1109/IEMBS.2004.1403648&rft_dat=%3Cieee_6IE%3E1403648%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1403648&rfr_iscdi=true