Sterilization in Plaxy Glass tube by microwave

Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Helhel, S., Oksuz, L., Cerezci, O., Rad, A.Y.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 194
container_title
container_volume
creator Helhel, S.
Oksuz, L.
Cerezci, O.
Rad, A.Y.
description Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different properties of the heavy particles. This study presents the effect of the system on the bacteria. They are gram positive and gram negative bacteria that refers to structure of the cell wall. The sterilization efficacy of microwave plasma was found to be over 99.5% in Staphylococcus aureus, Staphylococcus epider-midis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Klebsiella pneumonia and Escherichia coli.
doi_str_mv 10.1109/PLASMA.2004.1339771
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1339771</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1339771</ieee_id><sourcerecordid>1339771</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-75c9c0b325c5ce52dcb33c48f0577bff6975529ce0dc7298585915e638b496b3</originalsourceid><addsrcrecordid>eNotj0tqwzAUAEU_UDfNCbLRBew-6elZ0tKENim4JODsg6TIoOIkxXY_7ulbaGYzu4FhbCGgEALs47aumteqkACqEIhWa3HFMkm6zLUEc83uQRtAg6jKG5aBRsitVOqOzYfhDf5QpIQSGSuaMfapSz9uTOcTTye-7dz3xFedGwY-fvjI_cSPKfTnL_cZH9ht67ohzi-eseb5abdc5_Vm9bKs6jxZGHNNwQbwKClQiCQPwSMGZVogrX3bllYTSRsiHIKW1pAhKyiWaLyypccZW_xXU4xx_96no-un_WUUfwHj10RQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Sterilization in Plaxy Glass tube by microwave</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Helhel, S. ; Oksuz, L. ; Cerezci, O. ; Rad, A.Y.</creator><creatorcontrib>Helhel, S. ; Oksuz, L. ; Cerezci, O. ; Rad, A.Y.</creatorcontrib><description>Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different properties of the heavy particles. This study presents the effect of the system on the bacteria. They are gram positive and gram negative bacteria that refers to structure of the cell wall. The sterilization efficacy of microwave plasma was found to be over 99.5% in Staphylococcus aureus, Staphylococcus epider-midis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Klebsiella pneumonia and Escherichia coli.</description><identifier>ISSN: 0730-9244</identifier><identifier>ISBN: 0780383346</identifier><identifier>ISBN: 9780780383340</identifier><identifier>EISSN: 2576-7208</identifier><identifier>DOI: 10.1109/PLASMA.2004.1339771</identifier><language>eng</language><publisher>IEEE</publisher><subject>Density measurement ; Electron tubes ; Glass ; Microorganisms ; Particle measurements ; Plasma applications ; Plasma measurements ; Plasma temperature ; Toroidal magnetic fields ; Vacuum systems</subject><ispartof>The 31st IEEE International Conference on Plasma Science, 2004. ICOPS 2004. IEEE Conference Record - Abstracts, 2004, p.194</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1339771$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1339771$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Helhel, S.</creatorcontrib><creatorcontrib>Oksuz, L.</creatorcontrib><creatorcontrib>Cerezci, O.</creatorcontrib><creatorcontrib>Rad, A.Y.</creatorcontrib><title>Sterilization in Plaxy Glass tube by microwave</title><title>The 31st IEEE International Conference on Plasma Science, 2004. ICOPS 2004. IEEE Conference Record - Abstracts</title><addtitle>PLASMA</addtitle><description>Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different properties of the heavy particles. This study presents the effect of the system on the bacteria. They are gram positive and gram negative bacteria that refers to structure of the cell wall. The sterilization efficacy of microwave plasma was found to be over 99.5% in Staphylococcus aureus, Staphylococcus epider-midis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Klebsiella pneumonia and Escherichia coli.</description><subject>Density measurement</subject><subject>Electron tubes</subject><subject>Glass</subject><subject>Microorganisms</subject><subject>Particle measurements</subject><subject>Plasma applications</subject><subject>Plasma measurements</subject><subject>Plasma temperature</subject><subject>Toroidal magnetic fields</subject><subject>Vacuum systems</subject><issn>0730-9244</issn><issn>2576-7208</issn><isbn>0780383346</isbn><isbn>9780780383340</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2004</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj0tqwzAUAEU_UDfNCbLRBew-6elZ0tKENim4JODsg6TIoOIkxXY_7ulbaGYzu4FhbCGgEALs47aumteqkACqEIhWa3HFMkm6zLUEc83uQRtAg6jKG5aBRsitVOqOzYfhDf5QpIQSGSuaMfapSz9uTOcTTye-7dz3xFedGwY-fvjI_cSPKfTnL_cZH9ht67ohzi-eseb5abdc5_Vm9bKs6jxZGHNNwQbwKClQiCQPwSMGZVogrX3bllYTSRsiHIKW1pAhKyiWaLyypccZW_xXU4xx_96no-un_WUUfwHj10RQ</recordid><startdate>2004</startdate><enddate>2004</enddate><creator>Helhel, S.</creator><creator>Oksuz, L.</creator><creator>Cerezci, O.</creator><creator>Rad, A.Y.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2004</creationdate><title>Sterilization in Plaxy Glass tube by microwave</title><author>Helhel, S. ; Oksuz, L. ; Cerezci, O. ; Rad, A.Y.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-75c9c0b325c5ce52dcb33c48f0577bff6975529ce0dc7298585915e638b496b3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Density measurement</topic><topic>Electron tubes</topic><topic>Glass</topic><topic>Microorganisms</topic><topic>Particle measurements</topic><topic>Plasma applications</topic><topic>Plasma measurements</topic><topic>Plasma temperature</topic><topic>Toroidal magnetic fields</topic><topic>Vacuum systems</topic><toplevel>online_resources</toplevel><creatorcontrib>Helhel, S.</creatorcontrib><creatorcontrib>Oksuz, L.</creatorcontrib><creatorcontrib>Cerezci, O.</creatorcontrib><creatorcontrib>Rad, A.Y.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Helhel, S.</au><au>Oksuz, L.</au><au>Cerezci, O.</au><au>Rad, A.Y.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Sterilization in Plaxy Glass tube by microwave</atitle><btitle>The 31st IEEE International Conference on Plasma Science, 2004. ICOPS 2004. IEEE Conference Record - Abstracts</btitle><stitle>PLASMA</stitle><date>2004</date><risdate>2004</risdate><spage>194</spage><pages>194-</pages><issn>0730-9244</issn><eissn>2576-7208</eissn><isbn>0780383346</isbn><isbn>9780780383340</isbn><abstract>Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different properties of the heavy particles. This study presents the effect of the system on the bacteria. They are gram positive and gram negative bacteria that refers to structure of the cell wall. The sterilization efficacy of microwave plasma was found to be over 99.5% in Staphylococcus aureus, Staphylococcus epider-midis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Klebsiella pneumonia and Escherichia coli.</abstract><pub>IEEE</pub><doi>10.1109/PLASMA.2004.1339771</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0730-9244
ispartof The 31st IEEE International Conference on Plasma Science, 2004. ICOPS 2004. IEEE Conference Record - Abstracts, 2004, p.194
issn 0730-9244
2576-7208
language eng
recordid cdi_ieee_primary_1339771
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Density measurement
Electron tubes
Glass
Microorganisms
Particle measurements
Plasma applications
Plasma measurements
Plasma temperature
Toroidal magnetic fields
Vacuum systems
title Sterilization in Plaxy Glass tube by microwave
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T09%3A40%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Sterilization%20in%20Plaxy%20Glass%20tube%20by%20microwave&rft.btitle=The%2031st%20IEEE%20International%20Conference%20on%20Plasma%20Science,%202004.%20ICOPS%202004.%20IEEE%20Conference%20Record%20-%20Abstracts&rft.au=Helhel,%20S.&rft.date=2004&rft.spage=194&rft.pages=194-&rft.issn=0730-9244&rft.eissn=2576-7208&rft.isbn=0780383346&rft.isbn_list=9780780383340&rft_id=info:doi/10.1109/PLASMA.2004.1339771&rft_dat=%3Cieee_6IE%3E1339771%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1339771&rfr_iscdi=true