Sterilization in Plaxy Glass tube by microwave
Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | 194 |
container_title | |
container_volume | |
creator | Helhel, S. Oksuz, L. Cerezci, O. Rad, A.Y. |
description | Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different properties of the heavy particles. This study presents the effect of the system on the bacteria. They are gram positive and gram negative bacteria that refers to structure of the cell wall. The sterilization efficacy of microwave plasma was found to be over 99.5% in Staphylococcus aureus, Staphylococcus epider-midis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Klebsiella pneumonia and Escherichia coli. |
doi_str_mv | 10.1109/PLASMA.2004.1339771 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1339771</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1339771</ieee_id><sourcerecordid>1339771</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-75c9c0b325c5ce52dcb33c48f0577bff6975529ce0dc7298585915e638b496b3</originalsourceid><addsrcrecordid>eNotj0tqwzAUAEU_UDfNCbLRBew-6elZ0tKENim4JODsg6TIoOIkxXY_7ulbaGYzu4FhbCGgEALs47aumteqkACqEIhWa3HFMkm6zLUEc83uQRtAg6jKG5aBRsitVOqOzYfhDf5QpIQSGSuaMfapSz9uTOcTTye-7dz3xFedGwY-fvjI_cSPKfTnL_cZH9ht67ohzi-eseb5abdc5_Vm9bKs6jxZGHNNwQbwKClQiCQPwSMGZVogrX3bllYTSRsiHIKW1pAhKyiWaLyypccZW_xXU4xx_96no-un_WUUfwHj10RQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Sterilization in Plaxy Glass tube by microwave</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Helhel, S. ; Oksuz, L. ; Cerezci, O. ; Rad, A.Y.</creator><creatorcontrib>Helhel, S. ; Oksuz, L. ; Cerezci, O. ; Rad, A.Y.</creatorcontrib><description>Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different properties of the heavy particles. This study presents the effect of the system on the bacteria. They are gram positive and gram negative bacteria that refers to structure of the cell wall. The sterilization efficacy of microwave plasma was found to be over 99.5% in Staphylococcus aureus, Staphylococcus epider-midis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Klebsiella pneumonia and Escherichia coli.</description><identifier>ISSN: 0730-9244</identifier><identifier>ISBN: 0780383346</identifier><identifier>ISBN: 9780780383340</identifier><identifier>EISSN: 2576-7208</identifier><identifier>DOI: 10.1109/PLASMA.2004.1339771</identifier><language>eng</language><publisher>IEEE</publisher><subject>Density measurement ; Electron tubes ; Glass ; Microorganisms ; Particle measurements ; Plasma applications ; Plasma measurements ; Plasma temperature ; Toroidal magnetic fields ; Vacuum systems</subject><ispartof>The 31st IEEE International Conference on Plasma Science, 2004. ICOPS 2004. IEEE Conference Record - Abstracts, 2004, p.194</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1339771$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1339771$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Helhel, S.</creatorcontrib><creatorcontrib>Oksuz, L.</creatorcontrib><creatorcontrib>Cerezci, O.</creatorcontrib><creatorcontrib>Rad, A.Y.</creatorcontrib><title>Sterilization in Plaxy Glass tube by microwave</title><title>The 31st IEEE International Conference on Plasma Science, 2004. ICOPS 2004. IEEE Conference Record - Abstracts</title><addtitle>PLASMA</addtitle><description>Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different properties of the heavy particles. This study presents the effect of the system on the bacteria. They are gram positive and gram negative bacteria that refers to structure of the cell wall. The sterilization efficacy of microwave plasma was found to be over 99.5% in Staphylococcus aureus, Staphylococcus epider-midis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Klebsiella pneumonia and Escherichia coli.</description><subject>Density measurement</subject><subject>Electron tubes</subject><subject>Glass</subject><subject>Microorganisms</subject><subject>Particle measurements</subject><subject>Plasma applications</subject><subject>Plasma measurements</subject><subject>Plasma temperature</subject><subject>Toroidal magnetic fields</subject><subject>Vacuum systems</subject><issn>0730-9244</issn><issn>2576-7208</issn><isbn>0780383346</isbn><isbn>9780780383340</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2004</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj0tqwzAUAEU_UDfNCbLRBew-6elZ0tKENim4JODsg6TIoOIkxXY_7ulbaGYzu4FhbCGgEALs47aumteqkACqEIhWa3HFMkm6zLUEc83uQRtAg6jKG5aBRsitVOqOzYfhDf5QpIQSGSuaMfapSz9uTOcTTye-7dz3xFedGwY-fvjI_cSPKfTnL_cZH9ht67ohzi-eseb5abdc5_Vm9bKs6jxZGHNNwQbwKClQiCQPwSMGZVogrX3bllYTSRsiHIKW1pAhKyiWaLyypccZW_xXU4xx_96no-un_WUUfwHj10RQ</recordid><startdate>2004</startdate><enddate>2004</enddate><creator>Helhel, S.</creator><creator>Oksuz, L.</creator><creator>Cerezci, O.</creator><creator>Rad, A.Y.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2004</creationdate><title>Sterilization in Plaxy Glass tube by microwave</title><author>Helhel, S. ; Oksuz, L. ; Cerezci, O. ; Rad, A.Y.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-75c9c0b325c5ce52dcb33c48f0577bff6975529ce0dc7298585915e638b496b3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Density measurement</topic><topic>Electron tubes</topic><topic>Glass</topic><topic>Microorganisms</topic><topic>Particle measurements</topic><topic>Plasma applications</topic><topic>Plasma measurements</topic><topic>Plasma temperature</topic><topic>Toroidal magnetic fields</topic><topic>Vacuum systems</topic><toplevel>online_resources</toplevel><creatorcontrib>Helhel, S.</creatorcontrib><creatorcontrib>Oksuz, L.</creatorcontrib><creatorcontrib>Cerezci, O.</creatorcontrib><creatorcontrib>Rad, A.Y.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Helhel, S.</au><au>Oksuz, L.</au><au>Cerezci, O.</au><au>Rad, A.Y.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Sterilization in Plaxy Glass tube by microwave</atitle><btitle>The 31st IEEE International Conference on Plasma Science, 2004. ICOPS 2004. IEEE Conference Record - Abstracts</btitle><stitle>PLASMA</stitle><date>2004</date><risdate>2004</risdate><spage>194</spage><pages>194-</pages><issn>0730-9244</issn><eissn>2576-7208</eissn><isbn>0780383346</isbn><isbn>9780780383340</isbn><abstract>Summary form only given. Microwave plasma was built to produce plasma in an axial direction. Plasma was initiated in a Plaxy Glass made vacuum tube using a 2.45 GHz commercial magnetron and the system was driven by a 14 A DC current passing through a 16 cm inner diameter toroid. Measurements with a Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different properties of the heavy particles. This study presents the effect of the system on the bacteria. They are gram positive and gram negative bacteria that refers to structure of the cell wall. The sterilization efficacy of microwave plasma was found to be over 99.5% in Staphylococcus aureus, Staphylococcus epider-midis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Klebsiella pneumonia and Escherichia coli.</abstract><pub>IEEE</pub><doi>10.1109/PLASMA.2004.1339771</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0730-9244 |
ispartof | The 31st IEEE International Conference on Plasma Science, 2004. ICOPS 2004. IEEE Conference Record - Abstracts, 2004, p.194 |
issn | 0730-9244 2576-7208 |
language | eng |
recordid | cdi_ieee_primary_1339771 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Density measurement Electron tubes Glass Microorganisms Particle measurements Plasma applications Plasma measurements Plasma temperature Toroidal magnetic fields Vacuum systems |
title | Sterilization in Plaxy Glass tube by microwave |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T09%3A40%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Sterilization%20in%20Plaxy%20Glass%20tube%20by%20microwave&rft.btitle=The%2031st%20IEEE%20International%20Conference%20on%20Plasma%20Science,%202004.%20ICOPS%202004.%20IEEE%20Conference%20Record%20-%20Abstracts&rft.au=Helhel,%20S.&rft.date=2004&rft.spage=194&rft.pages=194-&rft.issn=0730-9244&rft.eissn=2576-7208&rft.isbn=0780383346&rft.isbn_list=9780780383340&rft_id=info:doi/10.1109/PLASMA.2004.1339771&rft_dat=%3Cieee_6IE%3E1339771%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1339771&rfr_iscdi=true |