Response characteristics of HVDC system according to frequency sensing methods
This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system are to fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the s...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2654 Vol.3 |
---|---|
container_issue | |
container_start_page | 2650 |
container_title | |
container_volume | 3 |
creator | Chan-Ki Kim Jong-Kwang Park Gil-Jo Jeong Jeong-Shik Ahn |
description | This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system are to fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is used a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC program and experimental test. |
doi_str_mv | 10.1109/IECON.2003.1280666 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1280666</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1280666</ieee_id><sourcerecordid>1280666</sourcerecordid><originalsourceid>FETCH-LOGICAL-i105t-1b10cf6d237f94536e661a5897dc7000f6fcc15975a1e71401a6e05e81f273023</originalsourceid><addsrcrecordid>eNotj8FOwzAQRC0hJKD0B-DiH0jYjWM7PqJQaKWqlRBwrYyzpkYkKbY55O8ponMZ6R1Gbxi7QSgRwdytFu12U1YAosSqAaXUGbsC3YDQBpS4YPOUPuGYWqI26pJtnikdxiERd3sbrcsUQ8rBJT56vnx7aHmaUqaeW-fG2IXhg-eR-0jfPzS4iSca0h_sKe_HLl2zc2-_Es1PPWOvj4uXdlmst0-r9n5dBASZC3xHcF51ldDe1FIoUgqtbIzunD7aeeWdQ2m0tEgaa0CrCCQ16CstoBIzdvu_G4hod4iht3HanS6LX_8KTHY</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Response characteristics of HVDC system according to frequency sensing methods</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Chan-Ki Kim ; Jong-Kwang Park ; Gil-Jo Jeong ; Jeong-Shik Ahn</creator><creatorcontrib>Chan-Ki Kim ; Jong-Kwang Park ; Gil-Jo Jeong ; Jeong-Shik Ahn</creatorcontrib><description>This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system are to fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is used a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC program and experimental test.</description><identifier>ISBN: 0780379063</identifier><identifier>ISBN: 9780780379060</identifier><identifier>DOI: 10.1109/IECON.2003.1280666</identifier><language>eng</language><publisher>IEEE</publisher><subject>Control systems ; Curve fitting ; Fires ; Frequency measurement ; HVDC transmission ; Robustness ; Shafts ; Synchronous generators ; Synchronous machines ; Valves</subject><ispartof>IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468), 2003, Vol.3, p.2650-2654 Vol.3</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1280666$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,4048,4049,27924,54919</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1280666$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Chan-Ki Kim</creatorcontrib><creatorcontrib>Jong-Kwang Park</creatorcontrib><creatorcontrib>Gil-Jo Jeong</creatorcontrib><creatorcontrib>Jeong-Shik Ahn</creatorcontrib><title>Response characteristics of HVDC system according to frequency sensing methods</title><title>IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)</title><addtitle>IECON</addtitle><description>This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system are to fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is used a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC program and experimental test.</description><subject>Control systems</subject><subject>Curve fitting</subject><subject>Fires</subject><subject>Frequency measurement</subject><subject>HVDC transmission</subject><subject>Robustness</subject><subject>Shafts</subject><subject>Synchronous generators</subject><subject>Synchronous machines</subject><subject>Valves</subject><isbn>0780379063</isbn><isbn>9780780379060</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2003</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj8FOwzAQRC0hJKD0B-DiH0jYjWM7PqJQaKWqlRBwrYyzpkYkKbY55O8ponMZ6R1Gbxi7QSgRwdytFu12U1YAosSqAaXUGbsC3YDQBpS4YPOUPuGYWqI26pJtnikdxiERd3sbrcsUQ8rBJT56vnx7aHmaUqaeW-fG2IXhg-eR-0jfPzS4iSca0h_sKe_HLl2zc2-_Es1PPWOvj4uXdlmst0-r9n5dBASZC3xHcF51ldDe1FIoUgqtbIzunD7aeeWdQ2m0tEgaa0CrCCQ16CstoBIzdvu_G4hod4iht3HanS6LX_8KTHY</recordid><startdate>2003</startdate><enddate>2003</enddate><creator>Chan-Ki Kim</creator><creator>Jong-Kwang Park</creator><creator>Gil-Jo Jeong</creator><creator>Jeong-Shik Ahn</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2003</creationdate><title>Response characteristics of HVDC system according to frequency sensing methods</title><author>Chan-Ki Kim ; Jong-Kwang Park ; Gil-Jo Jeong ; Jeong-Shik Ahn</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i105t-1b10cf6d237f94536e661a5897dc7000f6fcc15975a1e71401a6e05e81f273023</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Control systems</topic><topic>Curve fitting</topic><topic>Fires</topic><topic>Frequency measurement</topic><topic>HVDC transmission</topic><topic>Robustness</topic><topic>Shafts</topic><topic>Synchronous generators</topic><topic>Synchronous machines</topic><topic>Valves</topic><toplevel>online_resources</toplevel><creatorcontrib>Chan-Ki Kim</creatorcontrib><creatorcontrib>Jong-Kwang Park</creatorcontrib><creatorcontrib>Gil-Jo Jeong</creatorcontrib><creatorcontrib>Jeong-Shik Ahn</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Chan-Ki Kim</au><au>Jong-Kwang Park</au><au>Gil-Jo Jeong</au><au>Jeong-Shik Ahn</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Response characteristics of HVDC system according to frequency sensing methods</atitle><btitle>IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)</btitle><stitle>IECON</stitle><date>2003</date><risdate>2003</risdate><volume>3</volume><spage>2650</spage><epage>2654 Vol.3</epage><pages>2650-2654 Vol.3</pages><isbn>0780379063</isbn><isbn>9780780379060</isbn><abstract>This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system are to fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is used a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC program and experimental test.</abstract><pub>IEEE</pub><doi>10.1109/IECON.2003.1280666</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 0780379063 |
ispartof | IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468), 2003, Vol.3, p.2650-2654 Vol.3 |
issn | |
language | eng |
recordid | cdi_ieee_primary_1280666 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Control systems Curve fitting Fires Frequency measurement HVDC transmission Robustness Shafts Synchronous generators Synchronous machines Valves |
title | Response characteristics of HVDC system according to frequency sensing methods |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T21%3A24%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Response%20characteristics%20of%20HVDC%20system%20according%20to%20frequency%20sensing%20methods&rft.btitle=IECON'03.%2029th%20Annual%20Conference%20of%20the%20IEEE%20Industrial%20Electronics%20Society%20(IEEE%20Cat.%20No.03CH37468)&rft.au=Chan-Ki%20Kim&rft.date=2003&rft.volume=3&rft.spage=2650&rft.epage=2654%20Vol.3&rft.pages=2650-2654%20Vol.3&rft.isbn=0780379063&rft.isbn_list=9780780379060&rft_id=info:doi/10.1109/IECON.2003.1280666&rft_dat=%3Cieee_6IE%3E1280666%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1280666&rfr_iscdi=true |