A 800 kW wind-diesel test bench based on the MADE AE-52 variable speed wind turbine

A field work have been made about the practical installation of a wind-diesel autonomous power system. A remarkable innovation on the control of the latter wind-diesel system is the ability of taking advantage of the kinetic energy available from the wind turbine. With such an extra energy, a power...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sanchez, J.A., Moreno, N., Vazquez, S., Carrasco, J.M., Galvan, E., Batista, C., Hurtado, S., Costales, G.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1319 Vol.2
container_issue
container_start_page 1314
container_title
container_volume 2
creator Sanchez, J.A.
Moreno, N.
Vazquez, S.
Carrasco, J.M.
Galvan, E.
Batista, C.
Hurtado, S.
Costales, G.
description A field work have been made about the practical installation of a wind-diesel autonomous power system. A remarkable innovation on the control of the latter wind-diesel system is the ability of taking advantage of the kinetic energy available from the wind turbine. With such an extra energy, a power quality improvement can be achieved in the presence of load commutations. Besides of that, a convenient power sharing out can be obtained, allowing a high renewable energy penetration and fuel savings. Several results show the behaviour of the whole system, apart of the power quality improvement.
doi_str_mv 10.1109/IECON.2003.1280244
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1280244</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1280244</ieee_id><sourcerecordid>1280244</sourcerecordid><originalsourceid>FETCH-LOGICAL-i105t-c587a60ec438bbc0977226068250d8ac565a644b44a5dde119a2d0cdd1d655f3</originalsourceid><addsrcrecordid>eNotj81Kw0AUhQdEUGtfQDf3BRLv_GayDDFqodqFBZdlfm7paIwlExXf3oo9m7P5zgeHsSuOJedY3yy6dvVUCkRZcmFRKHXCLrCyKKsajTxj85xf8RCleVWbc_bcgEWEtxf4TkMsYqJMPUyUJ_A0hB14lynCxwDTjuCxue2g6Qot4MuNyfmeIO_pAPytYfocfRrokp1uXZ9pfuwZW9916_ahWK7uF22zLBJHPRVB28oZpKCk9T5gXVVCGDRWaIzWBW20M0p5pZyOkTivnYgYYuTRaL2VM3b9r01EtNmP6d2NP5vjbfkL61BLIA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A 800 kW wind-diesel test bench based on the MADE AE-52 variable speed wind turbine</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Sanchez, J.A. ; Moreno, N. ; Vazquez, S. ; Carrasco, J.M. ; Galvan, E. ; Batista, C. ; Hurtado, S. ; Costales, G.</creator><creatorcontrib>Sanchez, J.A. ; Moreno, N. ; Vazquez, S. ; Carrasco, J.M. ; Galvan, E. ; Batista, C. ; Hurtado, S. ; Costales, G.</creatorcontrib><description>A field work have been made about the practical installation of a wind-diesel autonomous power system. A remarkable innovation on the control of the latter wind-diesel system is the ability of taking advantage of the kinetic energy available from the wind turbine. With such an extra energy, a power quality improvement can be achieved in the presence of load commutations. Besides of that, a convenient power sharing out can be obtained, allowing a high renewable energy penetration and fuel savings. Several results show the behaviour of the whole system, apart of the power quality improvement.</description><identifier>ISBN: 0780379063</identifier><identifier>ISBN: 9780780379060</identifier><identifier>DOI: 10.1109/IECON.2003.1280244</identifier><language>eng</language><publisher>IEEE</publisher><subject>Control systems ; Electric variables control ; Hybrid power systems ; Power generation ; Power quality ; Power systems ; System testing ; Wind energy generation ; Wind speed ; Wind turbines</subject><ispartof>IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468), 2003, Vol.2, p.1314-1319 Vol.2</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1280244$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1280244$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Sanchez, J.A.</creatorcontrib><creatorcontrib>Moreno, N.</creatorcontrib><creatorcontrib>Vazquez, S.</creatorcontrib><creatorcontrib>Carrasco, J.M.</creatorcontrib><creatorcontrib>Galvan, E.</creatorcontrib><creatorcontrib>Batista, C.</creatorcontrib><creatorcontrib>Hurtado, S.</creatorcontrib><creatorcontrib>Costales, G.</creatorcontrib><title>A 800 kW wind-diesel test bench based on the MADE AE-52 variable speed wind turbine</title><title>IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)</title><addtitle>IECON</addtitle><description>A field work have been made about the practical installation of a wind-diesel autonomous power system. A remarkable innovation on the control of the latter wind-diesel system is the ability of taking advantage of the kinetic energy available from the wind turbine. With such an extra energy, a power quality improvement can be achieved in the presence of load commutations. Besides of that, a convenient power sharing out can be obtained, allowing a high renewable energy penetration and fuel savings. Several results show the behaviour of the whole system, apart of the power quality improvement.</description><subject>Control systems</subject><subject>Electric variables control</subject><subject>Hybrid power systems</subject><subject>Power generation</subject><subject>Power quality</subject><subject>Power systems</subject><subject>System testing</subject><subject>Wind energy generation</subject><subject>Wind speed</subject><subject>Wind turbines</subject><isbn>0780379063</isbn><isbn>9780780379060</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2003</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj81Kw0AUhQdEUGtfQDf3BRLv_GayDDFqodqFBZdlfm7paIwlExXf3oo9m7P5zgeHsSuOJedY3yy6dvVUCkRZcmFRKHXCLrCyKKsajTxj85xf8RCleVWbc_bcgEWEtxf4TkMsYqJMPUyUJ_A0hB14lynCxwDTjuCxue2g6Qot4MuNyfmeIO_pAPytYfocfRrokp1uXZ9pfuwZW9916_ahWK7uF22zLBJHPRVB28oZpKCk9T5gXVVCGDRWaIzWBW20M0p5pZyOkTivnYgYYuTRaL2VM3b9r01EtNmP6d2NP5vjbfkL61BLIA</recordid><startdate>2003</startdate><enddate>2003</enddate><creator>Sanchez, J.A.</creator><creator>Moreno, N.</creator><creator>Vazquez, S.</creator><creator>Carrasco, J.M.</creator><creator>Galvan, E.</creator><creator>Batista, C.</creator><creator>Hurtado, S.</creator><creator>Costales, G.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2003</creationdate><title>A 800 kW wind-diesel test bench based on the MADE AE-52 variable speed wind turbine</title><author>Sanchez, J.A. ; Moreno, N. ; Vazquez, S. ; Carrasco, J.M. ; Galvan, E. ; Batista, C. ; Hurtado, S. ; Costales, G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i105t-c587a60ec438bbc0977226068250d8ac565a644b44a5dde119a2d0cdd1d655f3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Control systems</topic><topic>Electric variables control</topic><topic>Hybrid power systems</topic><topic>Power generation</topic><topic>Power quality</topic><topic>Power systems</topic><topic>System testing</topic><topic>Wind energy generation</topic><topic>Wind speed</topic><topic>Wind turbines</topic><toplevel>online_resources</toplevel><creatorcontrib>Sanchez, J.A.</creatorcontrib><creatorcontrib>Moreno, N.</creatorcontrib><creatorcontrib>Vazquez, S.</creatorcontrib><creatorcontrib>Carrasco, J.M.</creatorcontrib><creatorcontrib>Galvan, E.</creatorcontrib><creatorcontrib>Batista, C.</creatorcontrib><creatorcontrib>Hurtado, S.</creatorcontrib><creatorcontrib>Costales, G.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Sanchez, J.A.</au><au>Moreno, N.</au><au>Vazquez, S.</au><au>Carrasco, J.M.</au><au>Galvan, E.</au><au>Batista, C.</au><au>Hurtado, S.</au><au>Costales, G.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A 800 kW wind-diesel test bench based on the MADE AE-52 variable speed wind turbine</atitle><btitle>IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)</btitle><stitle>IECON</stitle><date>2003</date><risdate>2003</risdate><volume>2</volume><spage>1314</spage><epage>1319 Vol.2</epage><pages>1314-1319 Vol.2</pages><isbn>0780379063</isbn><isbn>9780780379060</isbn><abstract>A field work have been made about the practical installation of a wind-diesel autonomous power system. A remarkable innovation on the control of the latter wind-diesel system is the ability of taking advantage of the kinetic energy available from the wind turbine. With such an extra energy, a power quality improvement can be achieved in the presence of load commutations. Besides of that, a convenient power sharing out can be obtained, allowing a high renewable energy penetration and fuel savings. Several results show the behaviour of the whole system, apart of the power quality improvement.</abstract><pub>IEEE</pub><doi>10.1109/IECON.2003.1280244</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 0780379063
ispartof IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468), 2003, Vol.2, p.1314-1319 Vol.2
issn
language eng
recordid cdi_ieee_primary_1280244
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Control systems
Electric variables control
Hybrid power systems
Power generation
Power quality
Power systems
System testing
Wind energy generation
Wind speed
Wind turbines
title A 800 kW wind-diesel test bench based on the MADE AE-52 variable speed wind turbine
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T08%3A48%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20800%20kW%20wind-diesel%20test%20bench%20based%20on%20the%20MADE%20AE-52%20variable%20speed%20wind%20turbine&rft.btitle=IECON'03.%2029th%20Annual%20Conference%20of%20the%20IEEE%20Industrial%20Electronics%20Society%20(IEEE%20Cat.%20No.03CH37468)&rft.au=Sanchez,%20J.A.&rft.date=2003&rft.volume=2&rft.spage=1314&rft.epage=1319%20Vol.2&rft.pages=1314-1319%20Vol.2&rft.isbn=0780379063&rft.isbn_list=9780780379060&rft_id=info:doi/10.1109/IECON.2003.1280244&rft_dat=%3Cieee_6IE%3E1280244%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1280244&rfr_iscdi=true