Comparison of three ENG tripolar cuff recording configurations

Cuff electrodes are a safe and reliable technique for long-term recording of the electroneurogram (ENG) from peripheral nerves. However, the usefulness of the recorded ENG depends on the amount of electromyogram (EMG) and stimulus artifact present. Interference cancellation may be offered by tripola...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Triantis, I.F., Demosthenous, A., Donaldson, N.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 367
container_issue
container_start_page 364
container_title
container_volume
creator Triantis, I.F.
Demosthenous, A.
Donaldson, N.
description Cuff electrodes are a safe and reliable technique for long-term recording of the electroneurogram (ENG) from peripheral nerves. However, the usefulness of the recorded ENG depends on the amount of electromyogram (EMG) and stimulus artifact present. Interference cancellation may be offered by tripolar cuff recording configurations, such as the quasi-tripole (QT) and the true-tripole (TT), but in practice their performance is severely degraded by cuff imbalance. The adaptive-tripole (AT) has been developed to compensate for possible cuff imbalance and hence minimize the interference pick-up on the recorded ENG. In this paper, the signal-to-interference ratios of the three tripolar cuff recording configurations are compared in-vivo in the presence of cuff imbalance. The results of the experiments, which were conducted using stimulation-induced signals, indicate that even though two different imbalances were present, the AT outperforms the other two configurations in the majority of cases.
doi_str_mv 10.1109/CNE.2003.1196836
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1196836</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1196836</ieee_id><sourcerecordid>1196836</sourcerecordid><originalsourceid>FETCH-LOGICAL-i173t-fac96faa9ba42edbd8cf97bdf7991f1837958c740482c6dc4bf503e3623da9023</originalsourceid><addsrcrecordid>eNotj8FKAzEURQMiqLV7wU1-YGqSN5PkbQQZxiqUutF1ySR5NdJOhsx04d9bsHdzOJsDl7EHKVZSCnxqt91KCQFnQ21BX7E7YawA0xiEG7acph9xHmBjAG_Zc5uPoytpygPPxOfvEiPvtms-lzTmgyvcn4h4iT6XkIY993mgtD8VN6c8TPfsmtxhissLF-zrtfts36rNx_q9fdlUSRqYK3IeNTmHvatVDH2wntD0gQyiJGnBYGO9qUVtldfB1z01AiJoBcGhULBgj__dFGPcjSUdXfndXS7CH0otR2s</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Comparison of three ENG tripolar cuff recording configurations</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Triantis, I.F. ; Demosthenous, A. ; Donaldson, N.</creator><creatorcontrib>Triantis, I.F. ; Demosthenous, A. ; Donaldson, N.</creatorcontrib><description>Cuff electrodes are a safe and reliable technique for long-term recording of the electroneurogram (ENG) from peripheral nerves. However, the usefulness of the recorded ENG depends on the amount of electromyogram (EMG) and stimulus artifact present. Interference cancellation may be offered by tripolar cuff recording configurations, such as the quasi-tripole (QT) and the true-tripole (TT), but in practice their performance is severely degraded by cuff imbalance. The adaptive-tripole (AT) has been developed to compensate for possible cuff imbalance and hence minimize the interference pick-up on the recorded ENG. In this paper, the signal-to-interference ratios of the three tripolar cuff recording configurations are compared in-vivo in the presence of cuff imbalance. The results of the experiments, which were conducted using stimulation-induced signals, indicate that even though two different imbalances were present, the AT outperforms the other two configurations in the majority of cases.</description><identifier>ISBN: 0780375793</identifier><identifier>ISBN: 9780780375796</identifier><identifier>DOI: 10.1109/CNE.2003.1196836</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biomedical electrodes ; Biomedical engineering ; Degradation ; Differential amplifiers ; Educational institutions ; Electromyography ; Filtering ; Insulation ; Interference cancellation ; Physics</subject><ispartof>First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings, 2003, p.364-367</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1196836$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,4036,4037,27904,54898</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1196836$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Triantis, I.F.</creatorcontrib><creatorcontrib>Demosthenous, A.</creatorcontrib><creatorcontrib>Donaldson, N.</creatorcontrib><title>Comparison of three ENG tripolar cuff recording configurations</title><title>First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings</title><addtitle>CNE</addtitle><description>Cuff electrodes are a safe and reliable technique for long-term recording of the electroneurogram (ENG) from peripheral nerves. However, the usefulness of the recorded ENG depends on the amount of electromyogram (EMG) and stimulus artifact present. Interference cancellation may be offered by tripolar cuff recording configurations, such as the quasi-tripole (QT) and the true-tripole (TT), but in practice their performance is severely degraded by cuff imbalance. The adaptive-tripole (AT) has been developed to compensate for possible cuff imbalance and hence minimize the interference pick-up on the recorded ENG. In this paper, the signal-to-interference ratios of the three tripolar cuff recording configurations are compared in-vivo in the presence of cuff imbalance. The results of the experiments, which were conducted using stimulation-induced signals, indicate that even though two different imbalances were present, the AT outperforms the other two configurations in the majority of cases.</description><subject>Biomedical electrodes</subject><subject>Biomedical engineering</subject><subject>Degradation</subject><subject>Differential amplifiers</subject><subject>Educational institutions</subject><subject>Electromyography</subject><subject>Filtering</subject><subject>Insulation</subject><subject>Interference cancellation</subject><subject>Physics</subject><isbn>0780375793</isbn><isbn>9780780375796</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2003</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj8FKAzEURQMiqLV7wU1-YGqSN5PkbQQZxiqUutF1ySR5NdJOhsx04d9bsHdzOJsDl7EHKVZSCnxqt91KCQFnQ21BX7E7YawA0xiEG7acph9xHmBjAG_Zc5uPoytpygPPxOfvEiPvtms-lzTmgyvcn4h4iT6XkIY993mgtD8VN6c8TPfsmtxhissLF-zrtfts36rNx_q9fdlUSRqYK3IeNTmHvatVDH2wntD0gQyiJGnBYGO9qUVtldfB1z01AiJoBcGhULBgj__dFGPcjSUdXfndXS7CH0otR2s</recordid><startdate>2003</startdate><enddate>2003</enddate><creator>Triantis, I.F.</creator><creator>Demosthenous, A.</creator><creator>Donaldson, N.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>2003</creationdate><title>Comparison of three ENG tripolar cuff recording configurations</title><author>Triantis, I.F. ; Demosthenous, A. ; Donaldson, N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i173t-fac96faa9ba42edbd8cf97bdf7991f1837958c740482c6dc4bf503e3623da9023</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Biomedical electrodes</topic><topic>Biomedical engineering</topic><topic>Degradation</topic><topic>Differential amplifiers</topic><topic>Educational institutions</topic><topic>Electromyography</topic><topic>Filtering</topic><topic>Insulation</topic><topic>Interference cancellation</topic><topic>Physics</topic><toplevel>online_resources</toplevel><creatorcontrib>Triantis, I.F.</creatorcontrib><creatorcontrib>Demosthenous, A.</creatorcontrib><creatorcontrib>Donaldson, N.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Triantis, I.F.</au><au>Demosthenous, A.</au><au>Donaldson, N.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Comparison of three ENG tripolar cuff recording configurations</atitle><btitle>First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings</btitle><stitle>CNE</stitle><date>2003</date><risdate>2003</risdate><spage>364</spage><epage>367</epage><pages>364-367</pages><isbn>0780375793</isbn><isbn>9780780375796</isbn><abstract>Cuff electrodes are a safe and reliable technique for long-term recording of the electroneurogram (ENG) from peripheral nerves. However, the usefulness of the recorded ENG depends on the amount of electromyogram (EMG) and stimulus artifact present. Interference cancellation may be offered by tripolar cuff recording configurations, such as the quasi-tripole (QT) and the true-tripole (TT), but in practice their performance is severely degraded by cuff imbalance. The adaptive-tripole (AT) has been developed to compensate for possible cuff imbalance and hence minimize the interference pick-up on the recorded ENG. In this paper, the signal-to-interference ratios of the three tripolar cuff recording configurations are compared in-vivo in the presence of cuff imbalance. The results of the experiments, which were conducted using stimulation-induced signals, indicate that even though two different imbalances were present, the AT outperforms the other two configurations in the majority of cases.</abstract><pub>IEEE</pub><doi>10.1109/CNE.2003.1196836</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 0780375793
ispartof First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings, 2003, p.364-367
issn
language eng
recordid cdi_ieee_primary_1196836
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Biomedical electrodes
Biomedical engineering
Degradation
Differential amplifiers
Educational institutions
Electromyography
Filtering
Insulation
Interference cancellation
Physics
title Comparison of three ENG tripolar cuff recording configurations
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T21%3A23%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Comparison%20of%20three%20ENG%20tripolar%20cuff%20recording%20configurations&rft.btitle=First%20International%20IEEE%20EMBS%20Conference%20on%20Neural%20Engineering,%202003.%20Conference%20Proceedings&rft.au=Triantis,%20I.F.&rft.date=2003&rft.spage=364&rft.epage=367&rft.pages=364-367&rft.isbn=0780375793&rft.isbn_list=9780780375796&rft_id=info:doi/10.1109/CNE.2003.1196836&rft_dat=%3Cieee_6IE%3E1196836%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1196836&rfr_iscdi=true