Thermoelectric air conditioner for railways - modifications, results, prospects

The general situation with air conditioning for railways is reported. Results of air conditioning unit modification and trials are shown. The description of basic prototype subassembly developed at RIF Corp. was presented at the XIX International Conference on Thermoelectrics. The comparison with th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ivanov, A.S., Varlamov, S.A., Emelyanov, V.V., Manko, A.N., Kopylov, S.A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 557
container_issue
container_start_page 554
container_title
container_volume
creator Ivanov, A.S.
Varlamov, S.A.
Emelyanov, V.V.
Manko, A.N.
Kopylov, S.A.
description The general situation with air conditioning for railways is reported. Results of air conditioning unit modification and trials are shown. The description of basic prototype subassembly developed at RIF Corp. was presented at the XIX International Conference on Thermoelectrics. The comparison with the basic prototype and improvements, concerning hot side liquid loop modification, water-to-air heat exchanger enhancement, and thermoelectric unit structure correction, are described. The results of laboratory tests and of running trials at Russian railways are reported. Economic evaluation is performed and commercial applicability for locomotive driver's cabin air-conditioning is reported. Topical questions of air conditioner further modification are discussed. The applicability of thermoelectric air-conditioning for a passenger railway coach is suggested.
doi_str_mv 10.1109/ICT.2002.1190378
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1190378</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1190378</ieee_id><sourcerecordid>1190378</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-94944c14f34311c2d646caacb58217c67a20823045ee7bd754e72979fd01a9883</originalsourceid><addsrcrecordid>eNotT81KAzEYDIig1t4LXvIAbs3fbpKjLGoLhV7Wc_mafEsju82SrEjf3oidy8wwMMwQsuJszTmzL9u2WwvGRHGWSW1uyAPTpqjGSHNHljl_sQJV8-Lvyb47YRojDujmFByFkKiLZx_mEM-YaB8TTRCGH7hkWtEx-tAHB39pfqYJ8_cwFzGlmKdSkR_JbQ9DxuWVF-Tz_a1rN9Vu_7FtX3dV4LqeK6usUo6rXirJuRO-UY0DcMfaCK5do0EwI2SZiaiPXtcKtbDa9p5xsMbIBXn67w2IeJhSGCFdDtfP8hfrg0yZ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Thermoelectric air conditioner for railways - modifications, results, prospects</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ivanov, A.S. ; Varlamov, S.A. ; Emelyanov, V.V. ; Manko, A.N. ; Kopylov, S.A.</creator><creatorcontrib>Ivanov, A.S. ; Varlamov, S.A. ; Emelyanov, V.V. ; Manko, A.N. ; Kopylov, S.A.</creatorcontrib><description>The general situation with air conditioning for railways is reported. Results of air conditioning unit modification and trials are shown. The description of basic prototype subassembly developed at RIF Corp. was presented at the XIX International Conference on Thermoelectrics. The comparison with the basic prototype and improvements, concerning hot side liquid loop modification, water-to-air heat exchanger enhancement, and thermoelectric unit structure correction, are described. The results of laboratory tests and of running trials at Russian railways are reported. Economic evaluation is performed and commercial applicability for locomotive driver's cabin air-conditioning is reported. Topical questions of air conditioner further modification are discussed. The applicability of thermoelectric air-conditioning for a passenger railway coach is suggested.</description><identifier>ISBN: 0780376838</identifier><identifier>ISBN: 9780780376830</identifier><identifier>DOI: 10.1109/ICT.2002.1190378</identifier><language>eng</language><publisher>IEEE</publisher><subject>Air conditioning ; Coolants ; Cooling ; Heat pumps ; Heat sinks ; Power system reliability ; Rail transportation ; Tellurium ; Thermoelectricity ; Water heating</subject><ispartof>Twenty-First International Conference on Thermoelectrics, 2002. Proceedings ICT '02, 2002, p.554-557</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1190378$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1190378$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ivanov, A.S.</creatorcontrib><creatorcontrib>Varlamov, S.A.</creatorcontrib><creatorcontrib>Emelyanov, V.V.</creatorcontrib><creatorcontrib>Manko, A.N.</creatorcontrib><creatorcontrib>Kopylov, S.A.</creatorcontrib><title>Thermoelectric air conditioner for railways - modifications, results, prospects</title><title>Twenty-First International Conference on Thermoelectrics, 2002. Proceedings ICT '02</title><addtitle>ICT</addtitle><description>The general situation with air conditioning for railways is reported. Results of air conditioning unit modification and trials are shown. The description of basic prototype subassembly developed at RIF Corp. was presented at the XIX International Conference on Thermoelectrics. The comparison with the basic prototype and improvements, concerning hot side liquid loop modification, water-to-air heat exchanger enhancement, and thermoelectric unit structure correction, are described. The results of laboratory tests and of running trials at Russian railways are reported. Economic evaluation is performed and commercial applicability for locomotive driver's cabin air-conditioning is reported. Topical questions of air conditioner further modification are discussed. The applicability of thermoelectric air-conditioning for a passenger railway coach is suggested.</description><subject>Air conditioning</subject><subject>Coolants</subject><subject>Cooling</subject><subject>Heat pumps</subject><subject>Heat sinks</subject><subject>Power system reliability</subject><subject>Rail transportation</subject><subject>Tellurium</subject><subject>Thermoelectricity</subject><subject>Water heating</subject><isbn>0780376838</isbn><isbn>9780780376830</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2002</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotT81KAzEYDIig1t4LXvIAbs3fbpKjLGoLhV7Wc_mafEsju82SrEjf3oidy8wwMMwQsuJszTmzL9u2WwvGRHGWSW1uyAPTpqjGSHNHljl_sQJV8-Lvyb47YRojDujmFByFkKiLZx_mEM-YaB8TTRCGH7hkWtEx-tAHB39pfqYJ8_cwFzGlmKdSkR_JbQ9DxuWVF-Tz_a1rN9Vu_7FtX3dV4LqeK6usUo6rXirJuRO-UY0DcMfaCK5do0EwI2SZiaiPXtcKtbDa9p5xsMbIBXn67w2IeJhSGCFdDtfP8hfrg0yZ</recordid><startdate>2002</startdate><enddate>2002</enddate><creator>Ivanov, A.S.</creator><creator>Varlamov, S.A.</creator><creator>Emelyanov, V.V.</creator><creator>Manko, A.N.</creator><creator>Kopylov, S.A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>2002</creationdate><title>Thermoelectric air conditioner for railways - modifications, results, prospects</title><author>Ivanov, A.S. ; Varlamov, S.A. ; Emelyanov, V.V. ; Manko, A.N. ; Kopylov, S.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-94944c14f34311c2d646caacb58217c67a20823045ee7bd754e72979fd01a9883</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Air conditioning</topic><topic>Coolants</topic><topic>Cooling</topic><topic>Heat pumps</topic><topic>Heat sinks</topic><topic>Power system reliability</topic><topic>Rail transportation</topic><topic>Tellurium</topic><topic>Thermoelectricity</topic><topic>Water heating</topic><toplevel>online_resources</toplevel><creatorcontrib>Ivanov, A.S.</creatorcontrib><creatorcontrib>Varlamov, S.A.</creatorcontrib><creatorcontrib>Emelyanov, V.V.</creatorcontrib><creatorcontrib>Manko, A.N.</creatorcontrib><creatorcontrib>Kopylov, S.A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ivanov, A.S.</au><au>Varlamov, S.A.</au><au>Emelyanov, V.V.</au><au>Manko, A.N.</au><au>Kopylov, S.A.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Thermoelectric air conditioner for railways - modifications, results, prospects</atitle><btitle>Twenty-First International Conference on Thermoelectrics, 2002. Proceedings ICT '02</btitle><stitle>ICT</stitle><date>2002</date><risdate>2002</risdate><spage>554</spage><epage>557</epage><pages>554-557</pages><isbn>0780376838</isbn><isbn>9780780376830</isbn><abstract>The general situation with air conditioning for railways is reported. Results of air conditioning unit modification and trials are shown. The description of basic prototype subassembly developed at RIF Corp. was presented at the XIX International Conference on Thermoelectrics. The comparison with the basic prototype and improvements, concerning hot side liquid loop modification, water-to-air heat exchanger enhancement, and thermoelectric unit structure correction, are described. The results of laboratory tests and of running trials at Russian railways are reported. Economic evaluation is performed and commercial applicability for locomotive driver's cabin air-conditioning is reported. Topical questions of air conditioner further modification are discussed. The applicability of thermoelectric air-conditioning for a passenger railway coach is suggested.</abstract><pub>IEEE</pub><doi>10.1109/ICT.2002.1190378</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 0780376838
ispartof Twenty-First International Conference on Thermoelectrics, 2002. Proceedings ICT '02, 2002, p.554-557
issn
language eng
recordid cdi_ieee_primary_1190378
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Air conditioning
Coolants
Cooling
Heat pumps
Heat sinks
Power system reliability
Rail transportation
Tellurium
Thermoelectricity
Water heating
title Thermoelectric air conditioner for railways - modifications, results, prospects
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T06%3A43%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Thermoelectric%20air%20conditioner%20for%20railways%20-%20modifications,%20results,%20prospects&rft.btitle=Twenty-First%20International%20Conference%20on%20Thermoelectrics,%202002.%20Proceedings%20ICT%20'02&rft.au=Ivanov,%20A.S.&rft.date=2002&rft.spage=554&rft.epage=557&rft.pages=554-557&rft.isbn=0780376838&rft.isbn_list=9780780376830&rft_id=info:doi/10.1109/ICT.2002.1190378&rft_dat=%3Cieee_6IE%3E1190378%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1190378&rfr_iscdi=true