Selection of the anti-EMP primary filtering devices in the power network and calculation study

The main technology measures of anti-EMP in the civil defense shelter department's power network are limiting and filtering circuits. High voltage and low voltage zinc-oxide (ZnO) lightning arresters are commonly selected for limiters. Filtering includes primary filtering and precise filtering....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Li Deju, Cui Chenhua, Ren Junhong, Su Xiaochen
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 122
container_issue
container_start_page 119
container_title
container_volume
creator Li Deju
Cui Chenhua
Ren Junhong
Su Xiaochen
description The main technology measures of anti-EMP in the civil defense shelter department's power network are limiting and filtering circuits. High voltage and low voltage zinc-oxide (ZnO) lightning arresters are commonly selected for limiters. Filtering includes primary filtering and precise filtering. In primary filtering devices, the low voltage non-power compensation condenser components are commonly changed into star connection and grounding. Before entering the high shielding area, special precise power filters, which are more expensive, are fitted. However, up to now, nobody has researched how to design and calculate the primary filtering devices in detail. We present methods for designing, selecting and calculating primary filtering devices, based on more than ten years' design experience. A table is presented of capacitor groups and capacitor value changes required for the design.
doi_str_mv 10.1109/ELMAGC.2002.1177380
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1177380</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1177380</ieee_id><sourcerecordid>1177380</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-ffb13de12da94193f0e6a89757b7b14fa56e4b8468fc1db14b0a030e87a4089a3</originalsourceid><addsrcrecordid>eNotkNFKw0AQRRdEUGq-oC_7A6mz2U1m97GEWIUUBfXVsklmdTUmJdla-veGNsPAwGXu4XIZWwpYCQHmvii3602-SgCSSUCUGq5YZFDDtBITRHHDonH8hmmkURLxln28Ukt18H3He8fDF3HbBR8X2xe-H_yvHU7c-TbQ4LtP3tCfr2nkvjt_7vsjDbyjcOyHn8nX8Nq29aG1Z9wYDs3pjl07244UzXfB3h-Kt_wxLp83T_m6jL3ANMTOVUI2JJLGGiWMdECZ1QZTrLASytk0I1VplWlXi2ZSKrAggTRaBdpYuWDLC9cT0W5OvptbkP_Kb1QL</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Selection of the anti-EMP primary filtering devices in the power network and calculation study</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Li Deju ; Cui Chenhua ; Ren Junhong ; Su Xiaochen</creator><creatorcontrib>Li Deju ; Cui Chenhua ; Ren Junhong ; Su Xiaochen</creatorcontrib><description>The main technology measures of anti-EMP in the civil defense shelter department's power network are limiting and filtering circuits. High voltage and low voltage zinc-oxide (ZnO) lightning arresters are commonly selected for limiters. Filtering includes primary filtering and precise filtering. In primary filtering devices, the low voltage non-power compensation condenser components are commonly changed into star connection and grounding. Before entering the high shielding area, special precise power filters, which are more expensive, are fitted. However, up to now, nobody has researched how to design and calculate the primary filtering devices in detail. We present methods for designing, selecting and calculating primary filtering devices, based on more than ten years' design experience. A table is presented of capacitor groups and capacitor value changes required for the design.</description><identifier>ISBN: 9780780372771</identifier><identifier>ISBN: 0780372778</identifier><identifier>DOI: 10.1109/ELMAGC.2002.1177380</identifier><language>eng</language><publisher>IEEE</publisher><subject>Arresters ; Capacitors ; Circuits ; Filtering ; Grounding ; Lightning ; Low voltage ; Power filters ; Power measurement ; Zinc oxide</subject><ispartof>2002 3rd International Symposium on Electromagnetic Compatibility, 2002, p.119-122</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1177380$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,4036,4037,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1177380$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Li Deju</creatorcontrib><creatorcontrib>Cui Chenhua</creatorcontrib><creatorcontrib>Ren Junhong</creatorcontrib><creatorcontrib>Su Xiaochen</creatorcontrib><title>Selection of the anti-EMP primary filtering devices in the power network and calculation study</title><title>2002 3rd International Symposium on Electromagnetic Compatibility</title><addtitle>ELMAGC</addtitle><description>The main technology measures of anti-EMP in the civil defense shelter department's power network are limiting and filtering circuits. High voltage and low voltage zinc-oxide (ZnO) lightning arresters are commonly selected for limiters. Filtering includes primary filtering and precise filtering. In primary filtering devices, the low voltage non-power compensation condenser components are commonly changed into star connection and grounding. Before entering the high shielding area, special precise power filters, which are more expensive, are fitted. However, up to now, nobody has researched how to design and calculate the primary filtering devices in detail. We present methods for designing, selecting and calculating primary filtering devices, based on more than ten years' design experience. A table is presented of capacitor groups and capacitor value changes required for the design.</description><subject>Arresters</subject><subject>Capacitors</subject><subject>Circuits</subject><subject>Filtering</subject><subject>Grounding</subject><subject>Lightning</subject><subject>Low voltage</subject><subject>Power filters</subject><subject>Power measurement</subject><subject>Zinc oxide</subject><isbn>9780780372771</isbn><isbn>0780372778</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2002</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkNFKw0AQRRdEUGq-oC_7A6mz2U1m97GEWIUUBfXVsklmdTUmJdla-veGNsPAwGXu4XIZWwpYCQHmvii3602-SgCSSUCUGq5YZFDDtBITRHHDonH8hmmkURLxln28Ukt18H3He8fDF3HbBR8X2xe-H_yvHU7c-TbQ4LtP3tCfr2nkvjt_7vsjDbyjcOyHn8nX8Nq29aG1Z9wYDs3pjl07244UzXfB3h-Kt_wxLp83T_m6jL3ANMTOVUI2JJLGGiWMdECZ1QZTrLASytk0I1VplWlXi2ZSKrAggTRaBdpYuWDLC9cT0W5OvptbkP_Kb1QL</recordid><startdate>2002</startdate><enddate>2002</enddate><creator>Li Deju</creator><creator>Cui Chenhua</creator><creator>Ren Junhong</creator><creator>Su Xiaochen</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>2002</creationdate><title>Selection of the anti-EMP primary filtering devices in the power network and calculation study</title><author>Li Deju ; Cui Chenhua ; Ren Junhong ; Su Xiaochen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-ffb13de12da94193f0e6a89757b7b14fa56e4b8468fc1db14b0a030e87a4089a3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Arresters</topic><topic>Capacitors</topic><topic>Circuits</topic><topic>Filtering</topic><topic>Grounding</topic><topic>Lightning</topic><topic>Low voltage</topic><topic>Power filters</topic><topic>Power measurement</topic><topic>Zinc oxide</topic><toplevel>online_resources</toplevel><creatorcontrib>Li Deju</creatorcontrib><creatorcontrib>Cui Chenhua</creatorcontrib><creatorcontrib>Ren Junhong</creatorcontrib><creatorcontrib>Su Xiaochen</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Li Deju</au><au>Cui Chenhua</au><au>Ren Junhong</au><au>Su Xiaochen</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Selection of the anti-EMP primary filtering devices in the power network and calculation study</atitle><btitle>2002 3rd International Symposium on Electromagnetic Compatibility</btitle><stitle>ELMAGC</stitle><date>2002</date><risdate>2002</risdate><spage>119</spage><epage>122</epage><pages>119-122</pages><isbn>9780780372771</isbn><isbn>0780372778</isbn><abstract>The main technology measures of anti-EMP in the civil defense shelter department's power network are limiting and filtering circuits. High voltage and low voltage zinc-oxide (ZnO) lightning arresters are commonly selected for limiters. Filtering includes primary filtering and precise filtering. In primary filtering devices, the low voltage non-power compensation condenser components are commonly changed into star connection and grounding. Before entering the high shielding area, special precise power filters, which are more expensive, are fitted. However, up to now, nobody has researched how to design and calculate the primary filtering devices in detail. We present methods for designing, selecting and calculating primary filtering devices, based on more than ten years' design experience. A table is presented of capacitor groups and capacitor value changes required for the design.</abstract><pub>IEEE</pub><doi>10.1109/ELMAGC.2002.1177380</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9780780372771
ispartof 2002 3rd International Symposium on Electromagnetic Compatibility, 2002, p.119-122
issn
language eng
recordid cdi_ieee_primary_1177380
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Arresters
Capacitors
Circuits
Filtering
Grounding
Lightning
Low voltage
Power filters
Power measurement
Zinc oxide
title Selection of the anti-EMP primary filtering devices in the power network and calculation study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T02%3A26%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Selection%20of%20the%20anti-EMP%20primary%20filtering%20devices%20in%20the%20power%20network%20and%20calculation%20study&rft.btitle=2002%203rd%20International%20Symposium%20on%20Electromagnetic%20Compatibility&rft.au=Li%20Deju&rft.date=2002&rft.spage=119&rft.epage=122&rft.pages=119-122&rft.isbn=9780780372771&rft.isbn_list=0780372778&rft_id=info:doi/10.1109/ELMAGC.2002.1177380&rft_dat=%3Cieee_6IE%3E1177380%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1177380&rfr_iscdi=true