Gas Infusion in Doubled Hermetic Enclosures

In certain critical applications it is current practice to incorporate sealed electron devices within an outer hermetic enclosure for increased seal assurance. An exact solution is now given for the gas influx into such a doubled hermetic enclosure when each enclosure has a given leak size. This sol...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on parts, hybrids, and packaging hybrids, and packaging, 1977-06, Vol.13 (2), p.110-116
1. Verfasser: Ruthberg, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 116
container_issue 2
container_start_page 110
container_title IEEE transactions on parts, hybrids, and packaging
container_volume 13
creator Ruthberg, S.
description In certain critical applications it is current practice to incorporate sealed electron devices within an outer hermetic enclosure for increased seal assurance. An exact solution is now given for the gas influx into such a doubled hermetic enclosure when each enclosure has a given leak size. This solution allows a comparison to be made between the leakage into a single isolated semiconductor package and that into the same package when it is protected by an outer enclosure. If the leaks are in the molecular flow regime, solutions for the pressure within the enclosures are of the form P_i = A_i e^{-(\alpha - \Beta)t} + B_i e^{-(\alpha + \beta)t} + P_b for i = 1,2, where P b is the external applied pressure at t > 0 and \alpha , \beta are constants whose values depend only on the ratios of leak rates and of volumes. The general behavior is described in terms of a merit factor as a measure of the hermetic improvement for doubled enclosures over that of a single enclosure, and characteristics are derived for a broad spectrum of system dimensions. It is shown that a significant improvement in hermeticity over a long time span is not an apriori result of using an outer enclosure.
doi_str_mv 10.1109/TPHP.1977.1135183
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_1135183</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1135183</ieee_id><sourcerecordid>10_1109_TPHP_1977_1135183</sourcerecordid><originalsourceid>FETCH-LOGICAL-c623-c8e96f872a0d4ead5686d70e89db39934f3619633d80ae6025cf52f6c4093de13</originalsourceid><addsrcrecordid>eNpFj8FKxDAQhoMoWFcfQLz0Ll0nSZMmR1nX7cKCe-g9ZJMJVLqtJPbg29uyhT39DP98w3yEPFNYUwr6rTnWxzXVVTWNXFDFb0hGhVAFK6W-JRlwSQsKAPfkIaVvAFYqrTPyurMp3_dhTO3Q522ffwzjqUOf1xjP-Nu6fNu7bkhjxPRI7oLtEj4tuSLN57bZ1MXha7ffvB8KJxkvnEItg6qYBV-i9UIq6StApf2Ja83LML2iJedegUUJTLggWJCuBM09Ur4i9HLWxSGliMH8xPZs45-hYGZZM8uaWdYsshPzcmFaRLzuL-0_Uf5PDA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Gas Infusion in Doubled Hermetic Enclosures</title><source>IEEE Xplore (Online service)</source><creator>Ruthberg, S.</creator><creatorcontrib>Ruthberg, S.</creatorcontrib><description>In certain critical applications it is current practice to incorporate sealed electron devices within an outer hermetic enclosure for increased seal assurance. An exact solution is now given for the gas influx into such a doubled hermetic enclosure when each enclosure has a given leak size. This solution allows a comparison to be made between the leakage into a single isolated semiconductor package and that into the same package when it is protected by an outer enclosure. If the leaks are in the molecular flow regime, solutions for the pressure within the enclosures are of the form P_i = A_i e^{-(\alpha - \Beta)t} + B_i e^{-(\alpha + \beta)t} + P_b for i = 1,2, where P b is the external applied pressure at t &gt; 0 and \alpha , \beta are constants whose values depend only on the ratios of leak rates and of volumes. The general behavior is described in terms of a merit factor as a measure of the hermetic improvement for doubled enclosures over that of a single enclosure, and characteristics are derived for a broad spectrum of system dimensions. It is shown that a significant improvement in hermeticity over a long time span is not an apriori result of using an outer enclosure.</description><identifier>ISSN: 0361-1000</identifier><identifier>EISSN: 1558-2469</identifier><identifier>DOI: 10.1109/TPHP.1977.1135183</identifier><language>eng</language><publisher>IEEE</publisher><subject>Atmosphere ; Atmospheric measurements ; Equations ; Measurement standards ; Pollution measurement ; Pressure measurement ; Semiconductor device packaging ; Semiconductor devices</subject><ispartof>IEEE transactions on parts, hybrids, and packaging, 1977-06, Vol.13 (2), p.110-116</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c623-c8e96f872a0d4ead5686d70e89db39934f3619633d80ae6025cf52f6c4093de13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1135183$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1135183$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ruthberg, S.</creatorcontrib><title>Gas Infusion in Doubled Hermetic Enclosures</title><title>IEEE transactions on parts, hybrids, and packaging</title><addtitle>T-CPT</addtitle><description>In certain critical applications it is current practice to incorporate sealed electron devices within an outer hermetic enclosure for increased seal assurance. An exact solution is now given for the gas influx into such a doubled hermetic enclosure when each enclosure has a given leak size. This solution allows a comparison to be made between the leakage into a single isolated semiconductor package and that into the same package when it is protected by an outer enclosure. If the leaks are in the molecular flow regime, solutions for the pressure within the enclosures are of the form P_i = A_i e^{-(\alpha - \Beta)t} + B_i e^{-(\alpha + \beta)t} + P_b for i = 1,2, where P b is the external applied pressure at t &gt; 0 and \alpha , \beta are constants whose values depend only on the ratios of leak rates and of volumes. The general behavior is described in terms of a merit factor as a measure of the hermetic improvement for doubled enclosures over that of a single enclosure, and characteristics are derived for a broad spectrum of system dimensions. It is shown that a significant improvement in hermeticity over a long time span is not an apriori result of using an outer enclosure.</description><subject>Atmosphere</subject><subject>Atmospheric measurements</subject><subject>Equations</subject><subject>Measurement standards</subject><subject>Pollution measurement</subject><subject>Pressure measurement</subject><subject>Semiconductor device packaging</subject><subject>Semiconductor devices</subject><issn>0361-1000</issn><issn>1558-2469</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1977</creationdate><recordtype>article</recordtype><recordid>eNpFj8FKxDAQhoMoWFcfQLz0Ll0nSZMmR1nX7cKCe-g9ZJMJVLqtJPbg29uyhT39DP98w3yEPFNYUwr6rTnWxzXVVTWNXFDFb0hGhVAFK6W-JRlwSQsKAPfkIaVvAFYqrTPyurMp3_dhTO3Q522ffwzjqUOf1xjP-Nu6fNu7bkhjxPRI7oLtEj4tuSLN57bZ1MXha7ffvB8KJxkvnEItg6qYBV-i9UIq6StApf2Ja83LML2iJedegUUJTLggWJCuBM09Ur4i9HLWxSGliMH8xPZs45-hYGZZM8uaWdYsshPzcmFaRLzuL-0_Uf5PDA</recordid><startdate>197706</startdate><enddate>197706</enddate><creator>Ruthberg, S.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>197706</creationdate><title>Gas Infusion in Doubled Hermetic Enclosures</title><author>Ruthberg, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c623-c8e96f872a0d4ead5686d70e89db39934f3619633d80ae6025cf52f6c4093de13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1977</creationdate><topic>Atmosphere</topic><topic>Atmospheric measurements</topic><topic>Equations</topic><topic>Measurement standards</topic><topic>Pollution measurement</topic><topic>Pressure measurement</topic><topic>Semiconductor device packaging</topic><topic>Semiconductor devices</topic><toplevel>online_resources</toplevel><creatorcontrib>Ruthberg, S.</creatorcontrib><collection>CrossRef</collection><jtitle>IEEE transactions on parts, hybrids, and packaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ruthberg, S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Gas Infusion in Doubled Hermetic Enclosures</atitle><jtitle>IEEE transactions on parts, hybrids, and packaging</jtitle><stitle>T-CPT</stitle><date>1977-06</date><risdate>1977</risdate><volume>13</volume><issue>2</issue><spage>110</spage><epage>116</epage><pages>110-116</pages><issn>0361-1000</issn><eissn>1558-2469</eissn><abstract>In certain critical applications it is current practice to incorporate sealed electron devices within an outer hermetic enclosure for increased seal assurance. An exact solution is now given for the gas influx into such a doubled hermetic enclosure when each enclosure has a given leak size. This solution allows a comparison to be made between the leakage into a single isolated semiconductor package and that into the same package when it is protected by an outer enclosure. If the leaks are in the molecular flow regime, solutions for the pressure within the enclosures are of the form P_i = A_i e^{-(\alpha - \Beta)t} + B_i e^{-(\alpha + \beta)t} + P_b for i = 1,2, where P b is the external applied pressure at t &gt; 0 and \alpha , \beta are constants whose values depend only on the ratios of leak rates and of volumes. The general behavior is described in terms of a merit factor as a measure of the hermetic improvement for doubled enclosures over that of a single enclosure, and characteristics are derived for a broad spectrum of system dimensions. It is shown that a significant improvement in hermeticity over a long time span is not an apriori result of using an outer enclosure.</abstract><pub>IEEE</pub><doi>10.1109/TPHP.1977.1135183</doi><tpages>7</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0361-1000
ispartof IEEE transactions on parts, hybrids, and packaging, 1977-06, Vol.13 (2), p.110-116
issn 0361-1000
1558-2469
language eng
recordid cdi_ieee_primary_1135183
source IEEE Xplore (Online service)
subjects Atmosphere
Atmospheric measurements
Equations
Measurement standards
Pollution measurement
Pressure measurement
Semiconductor device packaging
Semiconductor devices
title Gas Infusion in Doubled Hermetic Enclosures
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T15%3A23%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Gas%20Infusion%20in%20Doubled%20Hermetic%20Enclosures&rft.jtitle=IEEE%20transactions%20on%20parts,%20hybrids,%20and%20packaging&rft.au=Ruthberg,%20S.&rft.date=1977-06&rft.volume=13&rft.issue=2&rft.spage=110&rft.epage=116&rft.pages=110-116&rft.issn=0361-1000&rft.eissn=1558-2469&rft_id=info:doi/10.1109/TPHP.1977.1135183&rft_dat=%3Ccrossref_RIE%3E10_1109_TPHP_1977_1135183%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1135183&rfr_iscdi=true