Effect of Combined Misalignments on Vibrations of a Single-Stage Spur Gear Transmission System: An Experimental Approach

Failures in mechanical power transmission systems can cause serious operating problems in the systems to which they belong. Misalignments in the shafts of gear transmission systems can produce transmission errors, increased bending stress at the base of the teeth, and increased normal wear between t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE access 2024, Vol.12, p.50030-50043
Hauptverfasser: Villalba, Rafael E. Tuiran, Ramirez, Heriberto E. Maury, Estrada, Hector Aguila, Lopez, Jose A. Onate, Gonzalez, Andres F. Ruge, Barrera, Katerin Osorio, Almanza, Luis G. Riveros, Corrales, Daniel E. Espinosa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 50043
container_issue
container_start_page 50030
container_title IEEE access
container_volume 12
creator Villalba, Rafael E. Tuiran
Ramirez, Heriberto E. Maury
Estrada, Hector Aguila
Lopez, Jose A. Onate
Gonzalez, Andres F. Ruge
Barrera, Katerin Osorio
Almanza, Luis G. Riveros
Corrales, Daniel E. Espinosa
description Failures in mechanical power transmission systems can cause serious operating problems in the systems to which they belong. Misalignments in the shafts of gear transmission systems can produce transmission errors, increased bending stress at the base of the teeth, and increased normal wear between the teeth. Because vibration analysis is very useful as a failure detection mechanism in stationary rotating equipment, the effect of shaft misalignment on vibration measurements was investigated in this study. Combined misalignments are studied because different types of misalignments occur simultaneously in real applications. The effect of a combination of axial, radial, and angular misalignments on vibration measurements in a spur gear transmission system was investigated. This study was developed through the design and construction of a test bench that allows different types of misalignment in a single-stage spur gear transmission system and vibration measurement through accelerometers installed in the support bearings. Indicators, such as kurtosis and skewness, were used to validate the results in the time domain. For the frequency domain analysis, an indicator was developed that compares the frequency spectra of misaligned conditions to the base spectrum in the aligned condition. The critical misalignment combinations were also identified. It was found that for the combined cases, the contact area between the teeth and the contact ratio were influencing factors. The quantitative effects of combined misalignments on vibration measurements were determined, which can be used as a preliminary diagnosis of this type of problem and as a basis for developing more robust prediction models.
doi_str_mv 10.1109/ACCESS.2024.3385371
format Article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_10491194</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10491194</ieee_id><doaj_id>oai_doaj_org_article_9524e219c019468bbac82d1b6d787a0a</doaj_id><sourcerecordid>3037646024</sourcerecordid><originalsourceid>FETCH-LOGICAL-c359t-a19ac337fec40c7e16916bcce398895d81f6fc63da13c5b1952ac6191dd547f93</originalsourceid><addsrcrecordid>eNpNkUFr3DAQhU1oISHNL0gOgp691Vi2bPW2mG0aSOnBaa9iLI-3WrySK3kh-ffR1qFEF4nhvTefeFl2C3wDwNWXbdvuum5T8KLcCNFUooaL7KoAqXJRCfnh3fsyu4nxwNNp0qiqr7Ln3TiSWZgfWeuPvXU0sB824mT37khuicw79tv2ARfrXTzrkHXW7SfKuwX3xLr5FNg9YWBPAV082hiTknUvcaHjV7Z1bPc8U7DnNJzYdp6DR_PnU_ZxxCnSzdt9nf36tntqv-ePP-8f2u1jbkSllhxBoRGiTpAlNzUlbJC9MSRU06hqaGCUo5FiQBCm6kFVBRoJCoahKutRievsYc0dPB70nDgwvGiPVv8b-LDXGBZrJtLJW1IBynBQpWz6Hk1TDNDLoW5q5JiyPq9Z6Qt_TxQXffCn4BK-FlzUspSpg6QSq8oEH2Og8f9W4PrcmF4b0-fG9FtjyXW3uiwRvXOUChKNeAWosJJS</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3037646024</pqid></control><display><type>article</type><title>Effect of Combined Misalignments on Vibrations of a Single-Stage Spur Gear Transmission System: An Experimental Approach</title><source>IEEE Open Access Journals</source><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Villalba, Rafael E. Tuiran ; Ramirez, Heriberto E. Maury ; Estrada, Hector Aguila ; Lopez, Jose A. Onate ; Gonzalez, Andres F. Ruge ; Barrera, Katerin Osorio ; Almanza, Luis G. Riveros ; Corrales, Daniel E. Espinosa</creator><creatorcontrib>Villalba, Rafael E. Tuiran ; Ramirez, Heriberto E. Maury ; Estrada, Hector Aguila ; Lopez, Jose A. Onate ; Gonzalez, Andres F. Ruge ; Barrera, Katerin Osorio ; Almanza, Luis G. Riveros ; Corrales, Daniel E. Espinosa</creatorcontrib><description>Failures in mechanical power transmission systems can cause serious operating problems in the systems to which they belong. Misalignments in the shafts of gear transmission systems can produce transmission errors, increased bending stress at the base of the teeth, and increased normal wear between the teeth. Because vibration analysis is very useful as a failure detection mechanism in stationary rotating equipment, the effect of shaft misalignment on vibration measurements was investigated in this study. Combined misalignments are studied because different types of misalignments occur simultaneously in real applications. The effect of a combination of axial, radial, and angular misalignments on vibration measurements in a spur gear transmission system was investigated. This study was developed through the design and construction of a test bench that allows different types of misalignment in a single-stage spur gear transmission system and vibration measurement through accelerometers installed in the support bearings. Indicators, such as kurtosis and skewness, were used to validate the results in the time domain. For the frequency domain analysis, an indicator was developed that compares the frequency spectra of misaligned conditions to the base spectrum in the aligned condition. The critical misalignment combinations were also identified. It was found that for the combined cases, the contact area between the teeth and the contact ratio were influencing factors. The quantitative effects of combined misalignments on vibration measurements were determined, which can be used as a preliminary diagnosis of this type of problem and as a basis for developing more robust prediction models.</description><identifier>ISSN: 2169-3536</identifier><identifier>EISSN: 2169-3536</identifier><identifier>DOI: 10.1109/ACCESS.2024.3385371</identifier><identifier>CODEN: IAECCG</identifier><language>eng</language><publisher>Piscataway: IEEE</publisher><subject>Accelerometers ; Bending stresses ; combined misalignment ; Failure detection ; Fasteners ; Fault diagnosis ; Frequency domain analysis ; Frequency spectrum ; Gears ; Kurtosis ; Mechanical drives ; Mechanical power transmission ; Misalignment ; Motors ; Power transmission ; Prediction models ; Shafts ; Solid modeling ; spur gear ; Spur gears ; Transmission error ; Vibration ; Vibration analysis ; Vibration measurement ; Vibrations</subject><ispartof>IEEE access, 2024, Vol.12, p.50030-50043</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2024</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c359t-a19ac337fec40c7e16916bcce398895d81f6fc63da13c5b1952ac6191dd547f93</cites><orcidid>0009-0004-7019-4936 ; 0000-0003-1337-2826 ; 0000-0002-2979-4372</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10491194$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,860,2096,4010,27610,27900,27901,27902,54908</link.rule.ids></links><search><creatorcontrib>Villalba, Rafael E. Tuiran</creatorcontrib><creatorcontrib>Ramirez, Heriberto E. Maury</creatorcontrib><creatorcontrib>Estrada, Hector Aguila</creatorcontrib><creatorcontrib>Lopez, Jose A. Onate</creatorcontrib><creatorcontrib>Gonzalez, Andres F. Ruge</creatorcontrib><creatorcontrib>Barrera, Katerin Osorio</creatorcontrib><creatorcontrib>Almanza, Luis G. Riveros</creatorcontrib><creatorcontrib>Corrales, Daniel E. Espinosa</creatorcontrib><title>Effect of Combined Misalignments on Vibrations of a Single-Stage Spur Gear Transmission System: An Experimental Approach</title><title>IEEE access</title><addtitle>Access</addtitle><description>Failures in mechanical power transmission systems can cause serious operating problems in the systems to which they belong. Misalignments in the shafts of gear transmission systems can produce transmission errors, increased bending stress at the base of the teeth, and increased normal wear between the teeth. Because vibration analysis is very useful as a failure detection mechanism in stationary rotating equipment, the effect of shaft misalignment on vibration measurements was investigated in this study. Combined misalignments are studied because different types of misalignments occur simultaneously in real applications. The effect of a combination of axial, radial, and angular misalignments on vibration measurements in a spur gear transmission system was investigated. This study was developed through the design and construction of a test bench that allows different types of misalignment in a single-stage spur gear transmission system and vibration measurement through accelerometers installed in the support bearings. Indicators, such as kurtosis and skewness, were used to validate the results in the time domain. For the frequency domain analysis, an indicator was developed that compares the frequency spectra of misaligned conditions to the base spectrum in the aligned condition. The critical misalignment combinations were also identified. It was found that for the combined cases, the contact area between the teeth and the contact ratio were influencing factors. The quantitative effects of combined misalignments on vibration measurements were determined, which can be used as a preliminary diagnosis of this type of problem and as a basis for developing more robust prediction models.</description><subject>Accelerometers</subject><subject>Bending stresses</subject><subject>combined misalignment</subject><subject>Failure detection</subject><subject>Fasteners</subject><subject>Fault diagnosis</subject><subject>Frequency domain analysis</subject><subject>Frequency spectrum</subject><subject>Gears</subject><subject>Kurtosis</subject><subject>Mechanical drives</subject><subject>Mechanical power transmission</subject><subject>Misalignment</subject><subject>Motors</subject><subject>Power transmission</subject><subject>Prediction models</subject><subject>Shafts</subject><subject>Solid modeling</subject><subject>spur gear</subject><subject>Spur gears</subject><subject>Transmission error</subject><subject>Vibration</subject><subject>Vibration analysis</subject><subject>Vibration measurement</subject><subject>Vibrations</subject><issn>2169-3536</issn><issn>2169-3536</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>RIE</sourceid><sourceid>DOA</sourceid><recordid>eNpNkUFr3DAQhU1oISHNL0gOgp691Vi2bPW2mG0aSOnBaa9iLI-3WrySK3kh-ffR1qFEF4nhvTefeFl2C3wDwNWXbdvuum5T8KLcCNFUooaL7KoAqXJRCfnh3fsyu4nxwNNp0qiqr7Ln3TiSWZgfWeuPvXU0sB824mT37khuicw79tv2ARfrXTzrkHXW7SfKuwX3xLr5FNg9YWBPAV082hiTknUvcaHjV7Z1bPc8U7DnNJzYdp6DR_PnU_ZxxCnSzdt9nf36tntqv-ePP-8f2u1jbkSllhxBoRGiTpAlNzUlbJC9MSRU06hqaGCUo5FiQBCm6kFVBRoJCoahKutRievsYc0dPB70nDgwvGiPVv8b-LDXGBZrJtLJW1IBynBQpWz6Hk1TDNDLoW5q5JiyPq9Z6Qt_TxQXffCn4BK-FlzUspSpg6QSq8oEH2Og8f9W4PrcmF4b0-fG9FtjyXW3uiwRvXOUChKNeAWosJJS</recordid><startdate>2024</startdate><enddate>2024</enddate><creator>Villalba, Rafael E. Tuiran</creator><creator>Ramirez, Heriberto E. Maury</creator><creator>Estrada, Hector Aguila</creator><creator>Lopez, Jose A. Onate</creator><creator>Gonzalez, Andres F. Ruge</creator><creator>Barrera, Katerin Osorio</creator><creator>Almanza, Luis G. Riveros</creator><creator>Corrales, Daniel E. Espinosa</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>DOA</scope><orcidid>https://orcid.org/0009-0004-7019-4936</orcidid><orcidid>https://orcid.org/0000-0003-1337-2826</orcidid><orcidid>https://orcid.org/0000-0002-2979-4372</orcidid></search><sort><creationdate>2024</creationdate><title>Effect of Combined Misalignments on Vibrations of a Single-Stage Spur Gear Transmission System: An Experimental Approach</title><author>Villalba, Rafael E. Tuiran ; Ramirez, Heriberto E. Maury ; Estrada, Hector Aguila ; Lopez, Jose A. Onate ; Gonzalez, Andres F. Ruge ; Barrera, Katerin Osorio ; Almanza, Luis G. Riveros ; Corrales, Daniel E. Espinosa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c359t-a19ac337fec40c7e16916bcce398895d81f6fc63da13c5b1952ac6191dd547f93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Accelerometers</topic><topic>Bending stresses</topic><topic>combined misalignment</topic><topic>Failure detection</topic><topic>Fasteners</topic><topic>Fault diagnosis</topic><topic>Frequency domain analysis</topic><topic>Frequency spectrum</topic><topic>Gears</topic><topic>Kurtosis</topic><topic>Mechanical drives</topic><topic>Mechanical power transmission</topic><topic>Misalignment</topic><topic>Motors</topic><topic>Power transmission</topic><topic>Prediction models</topic><topic>Shafts</topic><topic>Solid modeling</topic><topic>spur gear</topic><topic>Spur gears</topic><topic>Transmission error</topic><topic>Vibration</topic><topic>Vibration analysis</topic><topic>Vibration measurement</topic><topic>Vibrations</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Villalba, Rafael E. Tuiran</creatorcontrib><creatorcontrib>Ramirez, Heriberto E. Maury</creatorcontrib><creatorcontrib>Estrada, Hector Aguila</creatorcontrib><creatorcontrib>Lopez, Jose A. Onate</creatorcontrib><creatorcontrib>Gonzalez, Andres F. Ruge</creatorcontrib><creatorcontrib>Barrera, Katerin Osorio</creatorcontrib><creatorcontrib>Almanza, Luis G. Riveros</creatorcontrib><creatorcontrib>Corrales, Daniel E. Espinosa</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>IEEE access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Villalba, Rafael E. Tuiran</au><au>Ramirez, Heriberto E. Maury</au><au>Estrada, Hector Aguila</au><au>Lopez, Jose A. Onate</au><au>Gonzalez, Andres F. Ruge</au><au>Barrera, Katerin Osorio</au><au>Almanza, Luis G. Riveros</au><au>Corrales, Daniel E. Espinosa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of Combined Misalignments on Vibrations of a Single-Stage Spur Gear Transmission System: An Experimental Approach</atitle><jtitle>IEEE access</jtitle><stitle>Access</stitle><date>2024</date><risdate>2024</risdate><volume>12</volume><spage>50030</spage><epage>50043</epage><pages>50030-50043</pages><issn>2169-3536</issn><eissn>2169-3536</eissn><coden>IAECCG</coden><abstract>Failures in mechanical power transmission systems can cause serious operating problems in the systems to which they belong. Misalignments in the shafts of gear transmission systems can produce transmission errors, increased bending stress at the base of the teeth, and increased normal wear between the teeth. Because vibration analysis is very useful as a failure detection mechanism in stationary rotating equipment, the effect of shaft misalignment on vibration measurements was investigated in this study. Combined misalignments are studied because different types of misalignments occur simultaneously in real applications. The effect of a combination of axial, radial, and angular misalignments on vibration measurements in a spur gear transmission system was investigated. This study was developed through the design and construction of a test bench that allows different types of misalignment in a single-stage spur gear transmission system and vibration measurement through accelerometers installed in the support bearings. Indicators, such as kurtosis and skewness, were used to validate the results in the time domain. For the frequency domain analysis, an indicator was developed that compares the frequency spectra of misaligned conditions to the base spectrum in the aligned condition. The critical misalignment combinations were also identified. It was found that for the combined cases, the contact area between the teeth and the contact ratio were influencing factors. The quantitative effects of combined misalignments on vibration measurements were determined, which can be used as a preliminary diagnosis of this type of problem and as a basis for developing more robust prediction models.</abstract><cop>Piscataway</cop><pub>IEEE</pub><doi>10.1109/ACCESS.2024.3385371</doi><tpages>14</tpages><orcidid>https://orcid.org/0009-0004-7019-4936</orcidid><orcidid>https://orcid.org/0000-0003-1337-2826</orcidid><orcidid>https://orcid.org/0000-0002-2979-4372</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2169-3536
ispartof IEEE access, 2024, Vol.12, p.50030-50043
issn 2169-3536
2169-3536
language eng
recordid cdi_ieee_primary_10491194
source IEEE Open Access Journals; DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Accelerometers
Bending stresses
combined misalignment
Failure detection
Fasteners
Fault diagnosis
Frequency domain analysis
Frequency spectrum
Gears
Kurtosis
Mechanical drives
Mechanical power transmission
Misalignment
Motors
Power transmission
Prediction models
Shafts
Solid modeling
spur gear
Spur gears
Transmission error
Vibration
Vibration analysis
Vibration measurement
Vibrations
title Effect of Combined Misalignments on Vibrations of a Single-Stage Spur Gear Transmission System: An Experimental Approach
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T22%3A49%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20Combined%20Misalignments%20on%20Vibrations%20of%20a%20Single-Stage%20Spur%20Gear%20Transmission%20System:%20An%20Experimental%20Approach&rft.jtitle=IEEE%20access&rft.au=Villalba,%20Rafael%20E.%20Tuiran&rft.date=2024&rft.volume=12&rft.spage=50030&rft.epage=50043&rft.pages=50030-50043&rft.issn=2169-3536&rft.eissn=2169-3536&rft.coden=IAECCG&rft_id=info:doi/10.1109/ACCESS.2024.3385371&rft_dat=%3Cproquest_ieee_%3E3037646024%3C/proquest_ieee_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3037646024&rft_id=info:pmid/&rft_ieee_id=10491194&rft_doaj_id=oai_doaj_org_article_9524e219c019468bbac82d1b6d787a0a&rfr_iscdi=true