A Compact Metamaterial Biosensor for Multi-Virus Detection With Tunability and High Incidence Angle Absorption

In this research, we introduce a metamaterial biosensor designed for the detection of various viruses. The proposed sensor configuration comprises four square split ring resonators (SRR) coupled with a central graphene ring. The strong coupling between SRR and graphene ring results in near-perfect a...