A hybrid natural/artificial electrostatic actuator for tactile stimulation

Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Agarwal, A.K., Nammi, K., Kaczmarek, K.A., Tyler, M.E., Beebe, D.J.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 345
container_issue
container_start_page 341
container_title
container_volume
creator Agarwal, A.K.
Nammi, K.
Kaczmarek, K.A.
Tyler, M.E.
Beebe, D.J.
description Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostatic tactile displays on a 4-inch wafer using standard clean room processing. Tactile perception studies performed on those showed that subjects could discriminate simple spatial geometric patterns. The focus of the current work is to develop a better understanding of the basic mechanism of perception (activation of receptors) during electrostatic stimulation at the skin-display interface. Three displays were constructed with polyimide (PI) dielectric layers of varying thickness. Studies were performed on human subjects to determine the dependence of threshold of sensation on the PI thickness using both the method of limits and two-alternate forced-choice techniques. The theoretical model for the behavior of the interface (a parallel-plate capacitor) suggests a linear relationship between voltage and dielectric thickness. However, our results indicate that the thickness has little or no effect on the threshold. The results are promising in that they may provide an indirect estimate of the depth of the subcutaneous conductive layer of the skin, and a better understanding of the interface.
doi_str_mv 10.1109/MMB.2002.1002343
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1002343</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1002343</ieee_id><sourcerecordid>1002343</sourcerecordid><originalsourceid>FETCH-LOGICAL-c222t-3a7225846a27da00ca4b13fb9579e6766bbd83be43739bd551d1207e59a85fb33</originalsourceid><addsrcrecordid>eNotT8tqwzAQFJRCS-p7oRf9gB1JK1nWMQ19ktBLew6rh6mKEhdZPuTvK2iGebAsDAwh95x1nDOz3u8fO8GY6Hg1kHBFGqMHVglaDkzdkGaef1iFVJL14pa8b-j32ebo6QnLkjGtMZc4Rhcx0ZCCK3maC5boKLqyYJkyHatKvWIKdC7xuKT6n0535HrENIfmkivy9fz0uX1tdx8vb9vNrnVCiNICaiHUIHsU2iNjDqXlMFqjtAm97ntr_QA2SNBgrFeKey6YDsrgoEYLsCIP_70xhHD4zfGI-Xy4LIY_9CRL_A</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A hybrid natural/artificial electrostatic actuator for tactile stimulation</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Agarwal, A.K. ; Nammi, K. ; Kaczmarek, K.A. ; Tyler, M.E. ; Beebe, D.J.</creator><creatorcontrib>Agarwal, A.K. ; Nammi, K. ; Kaczmarek, K.A. ; Tyler, M.E. ; Beebe, D.J.</creatorcontrib><description>Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostatic tactile displays on a 4-inch wafer using standard clean room processing. Tactile perception studies performed on those showed that subjects could discriminate simple spatial geometric patterns. The focus of the current work is to develop a better understanding of the basic mechanism of perception (activation of receptors) during electrostatic stimulation at the skin-display interface. Three displays were constructed with polyimide (PI) dielectric layers of varying thickness. Studies were performed on human subjects to determine the dependence of threshold of sensation on the PI thickness using both the method of limits and two-alternate forced-choice techniques. The theoretical model for the behavior of the interface (a parallel-plate capacitor) suggests a linear relationship between voltage and dielectric thickness. However, our results indicate that the thickness has little or no effect on the threshold. The results are promising in that they may provide an indirect estimate of the depth of the subcutaneous conductive layer of the skin, and a better understanding of the interface.</description><identifier>ISBN: 9780780374805</identifier><identifier>ISBN: 0780374800</identifier><identifier>DOI: 10.1109/MMB.2002.1002343</identifier><language>eng</language><publisher>IEEE</publisher><subject>Auditory displays ; Computer displays ; Dielectrics ; Electrostatic actuators ; Fabrication ; Fingers ; Haptic interfaces ; Humans ; Polyimides ; Skin</subject><ispartof>2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578), 2002, p.341-345</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c222t-3a7225846a27da00ca4b13fb9579e6766bbd83be43739bd551d1207e59a85fb33</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1002343$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2051,4035,4036,27904,54898</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1002343$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Agarwal, A.K.</creatorcontrib><creatorcontrib>Nammi, K.</creatorcontrib><creatorcontrib>Kaczmarek, K.A.</creatorcontrib><creatorcontrib>Tyler, M.E.</creatorcontrib><creatorcontrib>Beebe, D.J.</creatorcontrib><title>A hybrid natural/artificial electrostatic actuator for tactile stimulation</title><title>2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578)</title><addtitle>MMB</addtitle><description>Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostatic tactile displays on a 4-inch wafer using standard clean room processing. Tactile perception studies performed on those showed that subjects could discriminate simple spatial geometric patterns. The focus of the current work is to develop a better understanding of the basic mechanism of perception (activation of receptors) during electrostatic stimulation at the skin-display interface. Three displays were constructed with polyimide (PI) dielectric layers of varying thickness. Studies were performed on human subjects to determine the dependence of threshold of sensation on the PI thickness using both the method of limits and two-alternate forced-choice techniques. The theoretical model for the behavior of the interface (a parallel-plate capacitor) suggests a linear relationship between voltage and dielectric thickness. However, our results indicate that the thickness has little or no effect on the threshold. The results are promising in that they may provide an indirect estimate of the depth of the subcutaneous conductive layer of the skin, and a better understanding of the interface.</description><subject>Auditory displays</subject><subject>Computer displays</subject><subject>Dielectrics</subject><subject>Electrostatic actuators</subject><subject>Fabrication</subject><subject>Fingers</subject><subject>Haptic interfaces</subject><subject>Humans</subject><subject>Polyimides</subject><subject>Skin</subject><isbn>9780780374805</isbn><isbn>0780374800</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2002</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotT8tqwzAQFJRCS-p7oRf9gB1JK1nWMQ19ktBLew6rh6mKEhdZPuTvK2iGebAsDAwh95x1nDOz3u8fO8GY6Hg1kHBFGqMHVglaDkzdkGaef1iFVJL14pa8b-j32ebo6QnLkjGtMZc4Rhcx0ZCCK3maC5boKLqyYJkyHatKvWIKdC7xuKT6n0535HrENIfmkivy9fz0uX1tdx8vb9vNrnVCiNICaiHUIHsU2iNjDqXlMFqjtAm97ntr_QA2SNBgrFeKey6YDsrgoEYLsCIP_70xhHD4zfGI-Xy4LIY_9CRL_A</recordid><startdate>2002</startdate><enddate>2002</enddate><creator>Agarwal, A.K.</creator><creator>Nammi, K.</creator><creator>Kaczmarek, K.A.</creator><creator>Tyler, M.E.</creator><creator>Beebe, D.J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>2002</creationdate><title>A hybrid natural/artificial electrostatic actuator for tactile stimulation</title><author>Agarwal, A.K. ; Nammi, K. ; Kaczmarek, K.A. ; Tyler, M.E. ; Beebe, D.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c222t-3a7225846a27da00ca4b13fb9579e6766bbd83be43739bd551d1207e59a85fb33</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Auditory displays</topic><topic>Computer displays</topic><topic>Dielectrics</topic><topic>Electrostatic actuators</topic><topic>Fabrication</topic><topic>Fingers</topic><topic>Haptic interfaces</topic><topic>Humans</topic><topic>Polyimides</topic><topic>Skin</topic><toplevel>online_resources</toplevel><creatorcontrib>Agarwal, A.K.</creatorcontrib><creatorcontrib>Nammi, K.</creatorcontrib><creatorcontrib>Kaczmarek, K.A.</creatorcontrib><creatorcontrib>Tyler, M.E.</creatorcontrib><creatorcontrib>Beebe, D.J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Agarwal, A.K.</au><au>Nammi, K.</au><au>Kaczmarek, K.A.</au><au>Tyler, M.E.</au><au>Beebe, D.J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A hybrid natural/artificial electrostatic actuator for tactile stimulation</atitle><btitle>2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578)</btitle><stitle>MMB</stitle><date>2002</date><risdate>2002</risdate><spage>341</spage><epage>345</epage><pages>341-345</pages><isbn>9780780374805</isbn><isbn>0780374800</isbn><abstract>Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostatic tactile displays on a 4-inch wafer using standard clean room processing. Tactile perception studies performed on those showed that subjects could discriminate simple spatial geometric patterns. The focus of the current work is to develop a better understanding of the basic mechanism of perception (activation of receptors) during electrostatic stimulation at the skin-display interface. Three displays were constructed with polyimide (PI) dielectric layers of varying thickness. Studies were performed on human subjects to determine the dependence of threshold of sensation on the PI thickness using both the method of limits and two-alternate forced-choice techniques. The theoretical model for the behavior of the interface (a parallel-plate capacitor) suggests a linear relationship between voltage and dielectric thickness. However, our results indicate that the thickness has little or no effect on the threshold. The results are promising in that they may provide an indirect estimate of the depth of the subcutaneous conductive layer of the skin, and a better understanding of the interface.</abstract><pub>IEEE</pub><doi>10.1109/MMB.2002.1002343</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9780780374805
ispartof 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578), 2002, p.341-345
issn
language eng
recordid cdi_ieee_primary_1002343
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Auditory displays
Computer displays
Dielectrics
Electrostatic actuators
Fabrication
Fingers
Haptic interfaces
Humans
Polyimides
Skin
title A hybrid natural/artificial electrostatic actuator for tactile stimulation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T13%3A15%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20hybrid%20natural/artificial%20electrostatic%20actuator%20for%20tactile%20stimulation&rft.btitle=2nd%20Annual%20International%20IEEE-EMBS%20Special%20Topic%20Conference%20on%20Microtechnologies%20in%20Medicine%20and%20Biology.%20Proceedings%20(Cat.%20No.02EX578)&rft.au=Agarwal,%20A.K.&rft.date=2002&rft.spage=341&rft.epage=345&rft.pages=341-345&rft.isbn=9780780374805&rft.isbn_list=0780374800&rft_id=info:doi/10.1109/MMB.2002.1002343&rft_dat=%3Cieee_6IE%3E1002343%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1002343&rfr_iscdi=true