A hybrid natural/artificial electrostatic actuator for tactile stimulation
Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostat...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 345 |
---|---|
container_issue | |
container_start_page | 341 |
container_title | |
container_volume | |
creator | Agarwal, A.K. Nammi, K. Kaczmarek, K.A. Tyler, M.E. Beebe, D.J. |
description | Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostatic tactile displays on a 4-inch wafer using standard clean room processing. Tactile perception studies performed on those showed that subjects could discriminate simple spatial geometric patterns. The focus of the current work is to develop a better understanding of the basic mechanism of perception (activation of receptors) during electrostatic stimulation at the skin-display interface. Three displays were constructed with polyimide (PI) dielectric layers of varying thickness. Studies were performed on human subjects to determine the dependence of threshold of sensation on the PI thickness using both the method of limits and two-alternate forced-choice techniques. The theoretical model for the behavior of the interface (a parallel-plate capacitor) suggests a linear relationship between voltage and dielectric thickness. However, our results indicate that the thickness has little or no effect on the threshold. The results are promising in that they may provide an indirect estimate of the depth of the subcutaneous conductive layer of the skin, and a better understanding of the interface. |
doi_str_mv | 10.1109/MMB.2002.1002343 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1002343</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1002343</ieee_id><sourcerecordid>1002343</sourcerecordid><originalsourceid>FETCH-LOGICAL-c222t-3a7225846a27da00ca4b13fb9579e6766bbd83be43739bd551d1207e59a85fb33</originalsourceid><addsrcrecordid>eNotT8tqwzAQFJRCS-p7oRf9gB1JK1nWMQ19ktBLew6rh6mKEhdZPuTvK2iGebAsDAwh95x1nDOz3u8fO8GY6Hg1kHBFGqMHVglaDkzdkGaef1iFVJL14pa8b-j32ebo6QnLkjGtMZc4Rhcx0ZCCK3maC5boKLqyYJkyHatKvWIKdC7xuKT6n0535HrENIfmkivy9fz0uX1tdx8vb9vNrnVCiNICaiHUIHsU2iNjDqXlMFqjtAm97ntr_QA2SNBgrFeKey6YDsrgoEYLsCIP_70xhHD4zfGI-Xy4LIY_9CRL_A</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A hybrid natural/artificial electrostatic actuator for tactile stimulation</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Agarwal, A.K. ; Nammi, K. ; Kaczmarek, K.A. ; Tyler, M.E. ; Beebe, D.J.</creator><creatorcontrib>Agarwal, A.K. ; Nammi, K. ; Kaczmarek, K.A. ; Tyler, M.E. ; Beebe, D.J.</creatorcontrib><description>Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostatic tactile displays on a 4-inch wafer using standard clean room processing. Tactile perception studies performed on those showed that subjects could discriminate simple spatial geometric patterns. The focus of the current work is to develop a better understanding of the basic mechanism of perception (activation of receptors) during electrostatic stimulation at the skin-display interface. Three displays were constructed with polyimide (PI) dielectric layers of varying thickness. Studies were performed on human subjects to determine the dependence of threshold of sensation on the PI thickness using both the method of limits and two-alternate forced-choice techniques. The theoretical model for the behavior of the interface (a parallel-plate capacitor) suggests a linear relationship between voltage and dielectric thickness. However, our results indicate that the thickness has little or no effect on the threshold. The results are promising in that they may provide an indirect estimate of the depth of the subcutaneous conductive layer of the skin, and a better understanding of the interface.</description><identifier>ISBN: 9780780374805</identifier><identifier>ISBN: 0780374800</identifier><identifier>DOI: 10.1109/MMB.2002.1002343</identifier><language>eng</language><publisher>IEEE</publisher><subject>Auditory displays ; Computer displays ; Dielectrics ; Electrostatic actuators ; Fabrication ; Fingers ; Haptic interfaces ; Humans ; Polyimides ; Skin</subject><ispartof>2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578), 2002, p.341-345</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c222t-3a7225846a27da00ca4b13fb9579e6766bbd83be43739bd551d1207e59a85fb33</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1002343$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2051,4035,4036,27904,54898</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1002343$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Agarwal, A.K.</creatorcontrib><creatorcontrib>Nammi, K.</creatorcontrib><creatorcontrib>Kaczmarek, K.A.</creatorcontrib><creatorcontrib>Tyler, M.E.</creatorcontrib><creatorcontrib>Beebe, D.J.</creatorcontrib><title>A hybrid natural/artificial electrostatic actuator for tactile stimulation</title><title>2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578)</title><addtitle>MMB</addtitle><description>Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostatic tactile displays on a 4-inch wafer using standard clean room processing. Tactile perception studies performed on those showed that subjects could discriminate simple spatial geometric patterns. The focus of the current work is to develop a better understanding of the basic mechanism of perception (activation of receptors) during electrostatic stimulation at the skin-display interface. Three displays were constructed with polyimide (PI) dielectric layers of varying thickness. Studies were performed on human subjects to determine the dependence of threshold of sensation on the PI thickness using both the method of limits and two-alternate forced-choice techniques. The theoretical model for the behavior of the interface (a parallel-plate capacitor) suggests a linear relationship between voltage and dielectric thickness. However, our results indicate that the thickness has little or no effect on the threshold. The results are promising in that they may provide an indirect estimate of the depth of the subcutaneous conductive layer of the skin, and a better understanding of the interface.</description><subject>Auditory displays</subject><subject>Computer displays</subject><subject>Dielectrics</subject><subject>Electrostatic actuators</subject><subject>Fabrication</subject><subject>Fingers</subject><subject>Haptic interfaces</subject><subject>Humans</subject><subject>Polyimides</subject><subject>Skin</subject><isbn>9780780374805</isbn><isbn>0780374800</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2002</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotT8tqwzAQFJRCS-p7oRf9gB1JK1nWMQ19ktBLew6rh6mKEhdZPuTvK2iGebAsDAwh95x1nDOz3u8fO8GY6Hg1kHBFGqMHVglaDkzdkGaef1iFVJL14pa8b-j32ebo6QnLkjGtMZc4Rhcx0ZCCK3maC5boKLqyYJkyHatKvWIKdC7xuKT6n0535HrENIfmkivy9fz0uX1tdx8vb9vNrnVCiNICaiHUIHsU2iNjDqXlMFqjtAm97ntr_QA2SNBgrFeKey6YDsrgoEYLsCIP_70xhHD4zfGI-Xy4LIY_9CRL_A</recordid><startdate>2002</startdate><enddate>2002</enddate><creator>Agarwal, A.K.</creator><creator>Nammi, K.</creator><creator>Kaczmarek, K.A.</creator><creator>Tyler, M.E.</creator><creator>Beebe, D.J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>2002</creationdate><title>A hybrid natural/artificial electrostatic actuator for tactile stimulation</title><author>Agarwal, A.K. ; Nammi, K. ; Kaczmarek, K.A. ; Tyler, M.E. ; Beebe, D.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c222t-3a7225846a27da00ca4b13fb9579e6766bbd83be43739bd551d1207e59a85fb33</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Auditory displays</topic><topic>Computer displays</topic><topic>Dielectrics</topic><topic>Electrostatic actuators</topic><topic>Fabrication</topic><topic>Fingers</topic><topic>Haptic interfaces</topic><topic>Humans</topic><topic>Polyimides</topic><topic>Skin</topic><toplevel>online_resources</toplevel><creatorcontrib>Agarwal, A.K.</creatorcontrib><creatorcontrib>Nammi, K.</creatorcontrib><creatorcontrib>Kaczmarek, K.A.</creatorcontrib><creatorcontrib>Tyler, M.E.</creatorcontrib><creatorcontrib>Beebe, D.J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Agarwal, A.K.</au><au>Nammi, K.</au><au>Kaczmarek, K.A.</au><au>Tyler, M.E.</au><au>Beebe, D.J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A hybrid natural/artificial electrostatic actuator for tactile stimulation</atitle><btitle>2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578)</btitle><stitle>MMB</stitle><date>2002</date><risdate>2002</risdate><spage>341</spage><epage>345</epage><pages>341-345</pages><isbn>9780780374805</isbn><isbn>0780374800</isbn><abstract>Two modes of tactile communication have been previously explored-electrocutaneous and electrostatic. The electrostatic mode has the significant advantage of not passing electrical current into tissue to effect stimulation of afferent touch nerves. In previous research, we microfabricated electrostatic tactile displays on a 4-inch wafer using standard clean room processing. Tactile perception studies performed on those showed that subjects could discriminate simple spatial geometric patterns. The focus of the current work is to develop a better understanding of the basic mechanism of perception (activation of receptors) during electrostatic stimulation at the skin-display interface. Three displays were constructed with polyimide (PI) dielectric layers of varying thickness. Studies were performed on human subjects to determine the dependence of threshold of sensation on the PI thickness using both the method of limits and two-alternate forced-choice techniques. The theoretical model for the behavior of the interface (a parallel-plate capacitor) suggests a linear relationship between voltage and dielectric thickness. However, our results indicate that the thickness has little or no effect on the threshold. The results are promising in that they may provide an indirect estimate of the depth of the subcutaneous conductive layer of the skin, and a better understanding of the interface.</abstract><pub>IEEE</pub><doi>10.1109/MMB.2002.1002343</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9780780374805 |
ispartof | 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578), 2002, p.341-345 |
issn | |
language | eng |
recordid | cdi_ieee_primary_1002343 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Auditory displays Computer displays Dielectrics Electrostatic actuators Fabrication Fingers Haptic interfaces Humans Polyimides Skin |
title | A hybrid natural/artificial electrostatic actuator for tactile stimulation |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T13%3A15%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20hybrid%20natural/artificial%20electrostatic%20actuator%20for%20tactile%20stimulation&rft.btitle=2nd%20Annual%20International%20IEEE-EMBS%20Special%20Topic%20Conference%20on%20Microtechnologies%20in%20Medicine%20and%20Biology.%20Proceedings%20(Cat.%20No.02EX578)&rft.au=Agarwal,%20A.K.&rft.date=2002&rft.spage=341&rft.epage=345&rft.pages=341-345&rft.isbn=9780780374805&rft.isbn_list=0780374800&rft_id=info:doi/10.1109/MMB.2002.1002343&rft_dat=%3Cieee_6IE%3E1002343%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1002343&rfr_iscdi=true |