Enhancement in air-cooling of lithium-ion battery packs using tapered airflow duct

Temperature uniformity and peak-temperature reduction of lithium-ion battery packs are critical for adequate battery performance, cycle life, and safety. In air-cooled battery packs that use conventional rectangular ducts for airflow, the insufficient cooling of cells near the duct outlet leads to t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of thermal engineering 2024-03, Vol.10 (2), p.375-385
Hauptverfasser: Satheesh, Vivek K., Krıshna, Navneet, Kushwah, Prakhar Singh, Garg, Ishan, Raı, Sharmista, Hebbar, Gurumoorthy S., Naır, Dileep V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 385
container_issue 2
container_start_page 375
container_title Journal of thermal engineering
container_volume 10
creator Satheesh, Vivek K.
Krıshna, Navneet
Kushwah, Prakhar Singh
Garg, Ishan
Raı, Sharmista
Hebbar, Gurumoorthy S.
Naır, Dileep V.
description Temperature uniformity and peak-temperature reduction of lithium-ion battery packs are critical for adequate battery performance, cycle life, and safety. In air-cooled battery packs that use conventional rectangular ducts for airflow, the insufficient cooling of cells near the duct outlet leads to temperature nonuniformity and a rise in peak temperature. This study proposes a simple method of using a converging, tapered airflow duct to attain temperature uniformity and reduce peak temperature in air-cooled lithium-ion battery packs. The conjugate forced convection heat transfer from the battery pack was investigated using computational fluid dynamics, and the computational model was validated using experimental results for a limiting case. The proposed converging taper provided to the airflow duct reduced the peak temperature rise and improved the temperature uniformity of the batteries. For the conventional duct, the boundary layer development and the increase in air temperature downstream resulted in hotspots on cells near the outlet. In contrast, for the proposed tapered duct, the flow velocity increased downstream, resulting in improved heat dissipation from the cells near the outlet. Furthermore, the study investigated the effects of taper angle, inlet velocity, and heat generation rate on the flow and thermal fields. Notably, with the increase in taper angle, owing to the increase in turbulent heat transfer near the exit, the location of peak temperature shifted from the exit region to the central region of the battery pack. The taper-induced improvement in cooling was evident over the entire range of inlet velocities and heat generation rates investigated in the study. The peak temperature rise and maximum temperature difference of the battery pack were reduced by up to 20% and 19%, respectively. The proposed method, being effective and simple, could find its application in the cooling arrangements for battery packs in electric vehicles.
doi_str_mv 10.18186/thermal.1448648
format Article
fullrecord <record><control><sourceid>idealonline_cross</sourceid><recordid>TN_cdi_idealonline_journals_IDEAL_168166</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>IDEAL_168166</sourcerecordid><originalsourceid>FETCH-LOGICAL-c271t-ac38a2f2437812b13732b0917bdf5fbb1eadb7a4ddb0e5c17cd783e04a7c25b03</originalsourceid><addsrcrecordid>eNpNkE1LAzEQhoMoWGrvHnP0sjWTZDfxWGrVQkEQPYd8rU3dTUo2i_TfW20PnuY9PDPv8CB0C2QOEmRzX7Y-97qbA-ey4fICTShwWQnJxeW_fI1mw7AjhIBoOKvlBL2t4lZH63sfCw4R65Arm1IX4idOLe5C2Yaxr0KK2OhSfD7gvbZfAx6HX6Tovc_e_a61XfrGbrTlBl21uhv87Dyn6ONp9b58qTavz-vlYlNZKqBU2jKpaUs5ExKoASYYNeQBhHFt3RoDXjsjNHfOEF9bENYJyTzhWlhaG8Km6O50NzivuxSPP3u1S2OOx1a1flwtNgoaCU1zRMkJtTkNQ_at2ufQ63xQQNSfQXU2qM4G2Q-XkGbJ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Enhancement in air-cooling of lithium-ion battery packs using tapered airflow duct</title><source>EZB Electronic Journals Library</source><creator>Satheesh, Vivek K. ; Krıshna, Navneet ; Kushwah, Prakhar Singh ; Garg, Ishan ; Raı, Sharmista ; Hebbar, Gurumoorthy S. ; Naır, Dileep V.</creator><contributor>Dalkılıç,Ahmet Selim</contributor><creatorcontrib>Satheesh, Vivek K. ; Krıshna, Navneet ; Kushwah, Prakhar Singh ; Garg, Ishan ; Raı, Sharmista ; Hebbar, Gurumoorthy S. ; Naır, Dileep V. ; Dalkılıç,Ahmet Selim</creatorcontrib><description>Temperature uniformity and peak-temperature reduction of lithium-ion battery packs are critical for adequate battery performance, cycle life, and safety. In air-cooled battery packs that use conventional rectangular ducts for airflow, the insufficient cooling of cells near the duct outlet leads to temperature nonuniformity and a rise in peak temperature. This study proposes a simple method of using a converging, tapered airflow duct to attain temperature uniformity and reduce peak temperature in air-cooled lithium-ion battery packs. The conjugate forced convection heat transfer from the battery pack was investigated using computational fluid dynamics, and the computational model was validated using experimental results for a limiting case. The proposed converging taper provided to the airflow duct reduced the peak temperature rise and improved the temperature uniformity of the batteries. For the conventional duct, the boundary layer development and the increase in air temperature downstream resulted in hotspots on cells near the outlet. In contrast, for the proposed tapered duct, the flow velocity increased downstream, resulting in improved heat dissipation from the cells near the outlet. Furthermore, the study investigated the effects of taper angle, inlet velocity, and heat generation rate on the flow and thermal fields. Notably, with the increase in taper angle, owing to the increase in turbulent heat transfer near the exit, the location of peak temperature shifted from the exit region to the central region of the battery pack. The taper-induced improvement in cooling was evident over the entire range of inlet velocities and heat generation rates investigated in the study. The peak temperature rise and maximum temperature difference of the battery pack were reduced by up to 20% and 19%, respectively. The proposed method, being effective and simple, could find its application in the cooling arrangements for battery packs in electric vehicles.</description><identifier>ISSN: 2148-7847</identifier><identifier>EISSN: 2148-7847</identifier><identifier>DOI: 10.18186/thermal.1448648</identifier><language>eng</language><publisher>Yildiz Technical University</publisher><subject>Bilim-Teknoloji ; Enerji ; Mühendislik</subject><ispartof>Journal of thermal engineering, 2024-03, Vol.10 (2), p.375-385</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c271t-ac38a2f2437812b13732b0917bdf5fbb1eadb7a4ddb0e5c17cd783e04a7c25b03</cites><orcidid>0000-0001-7570-991X ; 0000-0002-8520-4437 ; 0000-0003-3060-3585 ; 0000-0001-9919-8632 ; 0000-0002-5989-9351 ; 0000-0002-2444-9609 ; 0000-0002-3717-2952</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><contributor>Dalkılıç,Ahmet Selim</contributor><creatorcontrib>Satheesh, Vivek K.</creatorcontrib><creatorcontrib>Krıshna, Navneet</creatorcontrib><creatorcontrib>Kushwah, Prakhar Singh</creatorcontrib><creatorcontrib>Garg, Ishan</creatorcontrib><creatorcontrib>Raı, Sharmista</creatorcontrib><creatorcontrib>Hebbar, Gurumoorthy S.</creatorcontrib><creatorcontrib>Naır, Dileep V.</creatorcontrib><title>Enhancement in air-cooling of lithium-ion battery packs using tapered airflow duct</title><title>Journal of thermal engineering</title><description>Temperature uniformity and peak-temperature reduction of lithium-ion battery packs are critical for adequate battery performance, cycle life, and safety. In air-cooled battery packs that use conventional rectangular ducts for airflow, the insufficient cooling of cells near the duct outlet leads to temperature nonuniformity and a rise in peak temperature. This study proposes a simple method of using a converging, tapered airflow duct to attain temperature uniformity and reduce peak temperature in air-cooled lithium-ion battery packs. The conjugate forced convection heat transfer from the battery pack was investigated using computational fluid dynamics, and the computational model was validated using experimental results for a limiting case. The proposed converging taper provided to the airflow duct reduced the peak temperature rise and improved the temperature uniformity of the batteries. For the conventional duct, the boundary layer development and the increase in air temperature downstream resulted in hotspots on cells near the outlet. In contrast, for the proposed tapered duct, the flow velocity increased downstream, resulting in improved heat dissipation from the cells near the outlet. Furthermore, the study investigated the effects of taper angle, inlet velocity, and heat generation rate on the flow and thermal fields. Notably, with the increase in taper angle, owing to the increase in turbulent heat transfer near the exit, the location of peak temperature shifted from the exit region to the central region of the battery pack. The taper-induced improvement in cooling was evident over the entire range of inlet velocities and heat generation rates investigated in the study. The peak temperature rise and maximum temperature difference of the battery pack were reduced by up to 20% and 19%, respectively. The proposed method, being effective and simple, could find its application in the cooling arrangements for battery packs in electric vehicles.</description><subject>Bilim-Teknoloji</subject><subject>Enerji</subject><subject>Mühendislik</subject><issn>2148-7847</issn><issn>2148-7847</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpNkE1LAzEQhoMoWGrvHnP0sjWTZDfxWGrVQkEQPYd8rU3dTUo2i_TfW20PnuY9PDPv8CB0C2QOEmRzX7Y-97qbA-ey4fICTShwWQnJxeW_fI1mw7AjhIBoOKvlBL2t4lZH63sfCw4R65Arm1IX4idOLe5C2Yaxr0KK2OhSfD7gvbZfAx6HX6Tovc_e_a61XfrGbrTlBl21uhv87Dyn6ONp9b58qTavz-vlYlNZKqBU2jKpaUs5ExKoASYYNeQBhHFt3RoDXjsjNHfOEF9bENYJyTzhWlhaG8Km6O50NzivuxSPP3u1S2OOx1a1flwtNgoaCU1zRMkJtTkNQ_at2ufQ63xQQNSfQXU2qM4G2Q-XkGbJ</recordid><startdate>20240301</startdate><enddate>20240301</enddate><creator>Satheesh, Vivek K.</creator><creator>Krıshna, Navneet</creator><creator>Kushwah, Prakhar Singh</creator><creator>Garg, Ishan</creator><creator>Raı, Sharmista</creator><creator>Hebbar, Gurumoorthy S.</creator><creator>Naır, Dileep V.</creator><general>Yildiz Technical University</general><scope>AAYXX</scope><scope>CITATION</scope><scope>IEBAR</scope><orcidid>https://orcid.org/0000-0001-7570-991X</orcidid><orcidid>https://orcid.org/0000-0002-8520-4437</orcidid><orcidid>https://orcid.org/0000-0003-3060-3585</orcidid><orcidid>https://orcid.org/0000-0001-9919-8632</orcidid><orcidid>https://orcid.org/0000-0002-5989-9351</orcidid><orcidid>https://orcid.org/0000-0002-2444-9609</orcidid><orcidid>https://orcid.org/0000-0002-3717-2952</orcidid></search><sort><creationdate>20240301</creationdate><title>Enhancement in air-cooling of lithium-ion battery packs using tapered airflow duct</title><author>Satheesh, Vivek K. ; Krıshna, Navneet ; Kushwah, Prakhar Singh ; Garg, Ishan ; Raı, Sharmista ; Hebbar, Gurumoorthy S. ; Naır, Dileep V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c271t-ac38a2f2437812b13732b0917bdf5fbb1eadb7a4ddb0e5c17cd783e04a7c25b03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Bilim-Teknoloji</topic><topic>Enerji</topic><topic>Mühendislik</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Satheesh, Vivek K.</creatorcontrib><creatorcontrib>Krıshna, Navneet</creatorcontrib><creatorcontrib>Kushwah, Prakhar Singh</creatorcontrib><creatorcontrib>Garg, Ishan</creatorcontrib><creatorcontrib>Raı, Sharmista</creatorcontrib><creatorcontrib>Hebbar, Gurumoorthy S.</creatorcontrib><creatorcontrib>Naır, Dileep V.</creatorcontrib><collection>CrossRef</collection><collection>Idealonline online kütüphane - Journals</collection><jtitle>Journal of thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Satheesh, Vivek K.</au><au>Krıshna, Navneet</au><au>Kushwah, Prakhar Singh</au><au>Garg, Ishan</au><au>Raı, Sharmista</au><au>Hebbar, Gurumoorthy S.</au><au>Naır, Dileep V.</au><au>Dalkılıç,Ahmet Selim</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Enhancement in air-cooling of lithium-ion battery packs using tapered airflow duct</atitle><jtitle>Journal of thermal engineering</jtitle><date>2024-03-01</date><risdate>2024</risdate><volume>10</volume><issue>2</issue><spage>375</spage><epage>385</epage><pages>375-385</pages><issn>2148-7847</issn><eissn>2148-7847</eissn><abstract>Temperature uniformity and peak-temperature reduction of lithium-ion battery packs are critical for adequate battery performance, cycle life, and safety. In air-cooled battery packs that use conventional rectangular ducts for airflow, the insufficient cooling of cells near the duct outlet leads to temperature nonuniformity and a rise in peak temperature. This study proposes a simple method of using a converging, tapered airflow duct to attain temperature uniformity and reduce peak temperature in air-cooled lithium-ion battery packs. The conjugate forced convection heat transfer from the battery pack was investigated using computational fluid dynamics, and the computational model was validated using experimental results for a limiting case. The proposed converging taper provided to the airflow duct reduced the peak temperature rise and improved the temperature uniformity of the batteries. For the conventional duct, the boundary layer development and the increase in air temperature downstream resulted in hotspots on cells near the outlet. In contrast, for the proposed tapered duct, the flow velocity increased downstream, resulting in improved heat dissipation from the cells near the outlet. Furthermore, the study investigated the effects of taper angle, inlet velocity, and heat generation rate on the flow and thermal fields. Notably, with the increase in taper angle, owing to the increase in turbulent heat transfer near the exit, the location of peak temperature shifted from the exit region to the central region of the battery pack. The taper-induced improvement in cooling was evident over the entire range of inlet velocities and heat generation rates investigated in the study. The peak temperature rise and maximum temperature difference of the battery pack were reduced by up to 20% and 19%, respectively. The proposed method, being effective and simple, could find its application in the cooling arrangements for battery packs in electric vehicles.</abstract><pub>Yildiz Technical University</pub><doi>10.18186/thermal.1448648</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-7570-991X</orcidid><orcidid>https://orcid.org/0000-0002-8520-4437</orcidid><orcidid>https://orcid.org/0000-0003-3060-3585</orcidid><orcidid>https://orcid.org/0000-0001-9919-8632</orcidid><orcidid>https://orcid.org/0000-0002-5989-9351</orcidid><orcidid>https://orcid.org/0000-0002-2444-9609</orcidid><orcidid>https://orcid.org/0000-0002-3717-2952</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2148-7847
ispartof Journal of thermal engineering, 2024-03, Vol.10 (2), p.375-385
issn 2148-7847
2148-7847
language eng
recordid cdi_idealonline_journals_IDEAL_168166
source EZB Electronic Journals Library
subjects Bilim-Teknoloji
Enerji
Mühendislik
title Enhancement in air-cooling of lithium-ion battery packs using tapered airflow duct
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T19%3A08%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-idealonline_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Enhancement%20in%20air-cooling%20of%20lithium-ion%20battery%20packs%20using%20tapered%20airflow%20duct&rft.jtitle=Journal%20of%20thermal%20engineering&rft.au=Satheesh,%20Vivek%20K.&rft.date=2024-03-01&rft.volume=10&rft.issue=2&rft.spage=375&rft.epage=385&rft.pages=375-385&rft.issn=2148-7847&rft.eissn=2148-7847&rft_id=info:doi/10.18186/thermal.1448648&rft_dat=%3Cidealonline_cross%3EIDEAL_168166%3C/idealonline_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true