Acceptance tests of the industrial series manufacturing of WEST ITER-like tungsten actively cooled divertor

The activelly cooled plasma facing units (PFUs) constituting the WEST lower divertor must meet strict technical specifications before their installation into the WEST tokamak. The tests performed at CEA lead mainly: to provide information on the feasibility to attach mechanically PFUs on sectors, to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica scripta 2021-12, Vol.96 (12), p.124029, Article 124029
Hauptverfasser: Richou, Marianne, Missirlian, Marc, Firdaouss, Mehdi, Böswirth, Bernd, Diez, Mathilde, Greuner, Henri, Hatchressian, Jean-Claude, Pérot, Nadia, Ramaniraka, Manda, Roche, Hélène
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The activelly cooled plasma facing units (PFUs) constituting the WEST lower divertor must meet strict technical specifications before their installation into the WEST tokamak. The tests performed at CEA lead mainly: to provide information on the feasibility to attach mechanically PFUs on sectors, to ensure geometrical tolerances for the welding of PFUs to water manifolds, to check the PFU vacuum tightness and to confirm the PFUs heat exhaust capability. Using high heat flux (HHF) test facilities, such as HADES at CEA-Cadarache and GLADIS at IPP-Garching, similar to 5% of the PFU production was tested. Infrared thermography (IR) tests were also performed (similar to 24% of the PFU production tested). We show that PFUs are with a quality in agreement to the requirements and that the assessement of the heat exhaust capability during the series production is needed. Based on statistical approaches, this work also provides information on the methods to assess the quality of tested components using statistic process control.
ISSN:0031-8949
1402-4896
DOI:10.1088/1402-4896/ac2657