Validity of dynamical analysis to characterize heart rate and oxygen consumption during effort tests
Abstract Performance is usually assessed by simple indices stemming from cardiac and respiratory data measured during graded exercise test. The goal of this study is to characterize the indices produced by a dynamical analysis of HR and VO 2 for different effort test protocols, and to estimate the c...
Gespeichert in:
Veröffentlicht in: | Scientific reports 2020-07, Vol.10 (1) |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1 |
container_start_page | |
container_title | Scientific reports |
container_volume | 10 |
creator | Mongin, D. Chabert, C. Uribe Caparros, A. Collado, A. Hermand, E. Hue, Olivier Alvero Cruz, J R Courvoisier, D S |
description | Abstract Performance is usually assessed by simple indices stemming from cardiac and respiratory data measured during graded exercise test. The goal of this study is to characterize the indices produced by a dynamical analysis of HR and VO 2 for different effort test protocols, and to estimate the construct validity of these new dynamical indices by testing their links with their standard counterparts. Therefore, two groups of 32 and 14 athletes from two different cohorts performed two different graded exercise testing before and after a period of training or deconditioning. Heart rate (HR) and oxygen consumption (VO 2 ) were measured. The new dynamical indices were the value without effort, the characteristic time and the amplitude (gain) of the HR and VO 2 response to the effort. The gain of HR was moderately to strongly associated with other performance indices, while the gain for VO 2 increased with training and decreased with deconditioning with an effect size slightly higher than VO 2 max. Dynamical analysis performed on the first 2/3 of the effort tests showed similar patterns than the analysis of the entire effort tests, which could be useful to assess individuals who cannot perform full effort tests. In conclusion, the dynamical analysis of HR and VO 2 obtained during effort test, especially through the estimation of the gain, provides a good characterization of physical performance, robust to less stringent effort test conditions. |
doi_str_mv | 10.1038/s41598-020-69218-1 |
format | Article |
fullrecord | <record><control><sourceid>hal</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_04585902v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_HAL_hal_04585902v1</sourcerecordid><originalsourceid>FETCH-hal_primary_oai_HAL_hal_04585902v13</originalsourceid><addsrcrecordid>eNqVjrFKBDEURYMouOj-gNVrLaJJZkYmpYiyhaVsOzwmmZ0nmWTJy4rx6x3Bwtbb3MvhFFeIG63utGr6e251Z3upjJIP1uhe6jOxMartpGmMOf-zL8WW-V2t6Yxttd0It8dAjkqFNIGrERcaMQBGDJWJoSQYZ8w4Fp_py8PsMRfIWPzqOEif9eAjjCnyaTkWShHcKVM8gJ-mtJrFc-FrcTFhYL_97Stx-_L89rSTM4bhmGnBXIeENOweX4cftv7tO6vMh27-434DXqdSiw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Validity of dynamical analysis to characterize heart rate and oxygen consumption during effort tests</title><source>Nature Free</source><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><source>Springer Nature OA Free Journals</source><creator>Mongin, D. ; Chabert, C. ; Uribe Caparros, A. ; Collado, A. ; Hermand, E. ; Hue, Olivier ; Alvero Cruz, J R ; Courvoisier, D S</creator><creatorcontrib>Mongin, D. ; Chabert, C. ; Uribe Caparros, A. ; Collado, A. ; Hermand, E. ; Hue, Olivier ; Alvero Cruz, J R ; Courvoisier, D S</creatorcontrib><description>Abstract Performance is usually assessed by simple indices stemming from cardiac and respiratory data measured during graded exercise test. The goal of this study is to characterize the indices produced by a dynamical analysis of HR and VO 2 for different effort test protocols, and to estimate the construct validity of these new dynamical indices by testing their links with their standard counterparts. Therefore, two groups of 32 and 14 athletes from two different cohorts performed two different graded exercise testing before and after a period of training or deconditioning. Heart rate (HR) and oxygen consumption (VO 2 ) were measured. The new dynamical indices were the value without effort, the characteristic time and the amplitude (gain) of the HR and VO 2 response to the effort. The gain of HR was moderately to strongly associated with other performance indices, while the gain for VO 2 increased with training and decreased with deconditioning with an effect size slightly higher than VO 2 max. Dynamical analysis performed on the first 2/3 of the effort tests showed similar patterns than the analysis of the entire effort tests, which could be useful to assess individuals who cannot perform full effort tests. In conclusion, the dynamical analysis of HR and VO 2 obtained during effort test, especially through the estimation of the gain, provides a good characterization of physical performance, robust to less stringent effort test conditions.</description><identifier>ISSN: 2045-2322</identifier><identifier>EISSN: 2045-2322</identifier><identifier>DOI: 10.1038/s41598-020-69218-1</identifier><language>eng</language><publisher>Nature Publishing Group</publisher><subject>Life Sciences</subject><ispartof>Scientific reports, 2020-07, Vol.10 (1)</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0002-2155-0816 ; 0000-0002-2155-0816</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,860,881,27901,27902</link.rule.ids><backlink>$$Uhttps://hal.univ-antilles.fr/hal-04585902$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Mongin, D.</creatorcontrib><creatorcontrib>Chabert, C.</creatorcontrib><creatorcontrib>Uribe Caparros, A.</creatorcontrib><creatorcontrib>Collado, A.</creatorcontrib><creatorcontrib>Hermand, E.</creatorcontrib><creatorcontrib>Hue, Olivier</creatorcontrib><creatorcontrib>Alvero Cruz, J R</creatorcontrib><creatorcontrib>Courvoisier, D S</creatorcontrib><title>Validity of dynamical analysis to characterize heart rate and oxygen consumption during effort tests</title><title>Scientific reports</title><description>Abstract Performance is usually assessed by simple indices stemming from cardiac and respiratory data measured during graded exercise test. The goal of this study is to characterize the indices produced by a dynamical analysis of HR and VO 2 for different effort test protocols, and to estimate the construct validity of these new dynamical indices by testing their links with their standard counterparts. Therefore, two groups of 32 and 14 athletes from two different cohorts performed two different graded exercise testing before and after a period of training or deconditioning. Heart rate (HR) and oxygen consumption (VO 2 ) were measured. The new dynamical indices were the value without effort, the characteristic time and the amplitude (gain) of the HR and VO 2 response to the effort. The gain of HR was moderately to strongly associated with other performance indices, while the gain for VO 2 increased with training and decreased with deconditioning with an effect size slightly higher than VO 2 max. Dynamical analysis performed on the first 2/3 of the effort tests showed similar patterns than the analysis of the entire effort tests, which could be useful to assess individuals who cannot perform full effort tests. In conclusion, the dynamical analysis of HR and VO 2 obtained during effort test, especially through the estimation of the gain, provides a good characterization of physical performance, robust to less stringent effort test conditions.</description><subject>Life Sciences</subject><issn>2045-2322</issn><issn>2045-2322</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqVjrFKBDEURYMouOj-gNVrLaJJZkYmpYiyhaVsOzwmmZ0nmWTJy4rx6x3Bwtbb3MvhFFeIG63utGr6e251Z3upjJIP1uhe6jOxMartpGmMOf-zL8WW-V2t6Yxttd0It8dAjkqFNIGrERcaMQBGDJWJoSQYZ8w4Fp_py8PsMRfIWPzqOEif9eAjjCnyaTkWShHcKVM8gJ-mtJrFc-FrcTFhYL_97Stx-_L89rSTM4bhmGnBXIeENOweX4cftv7tO6vMh27-434DXqdSiw</recordid><startdate>20200724</startdate><enddate>20200724</enddate><creator>Mongin, D.</creator><creator>Chabert, C.</creator><creator>Uribe Caparros, A.</creator><creator>Collado, A.</creator><creator>Hermand, E.</creator><creator>Hue, Olivier</creator><creator>Alvero Cruz, J R</creator><creator>Courvoisier, D S</creator><general>Nature Publishing Group</general><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0002-2155-0816</orcidid><orcidid>https://orcid.org/0000-0002-2155-0816</orcidid></search><sort><creationdate>20200724</creationdate><title>Validity of dynamical analysis to characterize heart rate and oxygen consumption during effort tests</title><author>Mongin, D. ; Chabert, C. ; Uribe Caparros, A. ; Collado, A. ; Hermand, E. ; Hue, Olivier ; Alvero Cruz, J R ; Courvoisier, D S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-hal_primary_oai_HAL_hal_04585902v13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Life Sciences</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mongin, D.</creatorcontrib><creatorcontrib>Chabert, C.</creatorcontrib><creatorcontrib>Uribe Caparros, A.</creatorcontrib><creatorcontrib>Collado, A.</creatorcontrib><creatorcontrib>Hermand, E.</creatorcontrib><creatorcontrib>Hue, Olivier</creatorcontrib><creatorcontrib>Alvero Cruz, J R</creatorcontrib><creatorcontrib>Courvoisier, D S</creatorcontrib><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Scientific reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mongin, D.</au><au>Chabert, C.</au><au>Uribe Caparros, A.</au><au>Collado, A.</au><au>Hermand, E.</au><au>Hue, Olivier</au><au>Alvero Cruz, J R</au><au>Courvoisier, D S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Validity of dynamical analysis to characterize heart rate and oxygen consumption during effort tests</atitle><jtitle>Scientific reports</jtitle><date>2020-07-24</date><risdate>2020</risdate><volume>10</volume><issue>1</issue><issn>2045-2322</issn><eissn>2045-2322</eissn><abstract>Abstract Performance is usually assessed by simple indices stemming from cardiac and respiratory data measured during graded exercise test. The goal of this study is to characterize the indices produced by a dynamical analysis of HR and VO 2 for different effort test protocols, and to estimate the construct validity of these new dynamical indices by testing their links with their standard counterparts. Therefore, two groups of 32 and 14 athletes from two different cohorts performed two different graded exercise testing before and after a period of training or deconditioning. Heart rate (HR) and oxygen consumption (VO 2 ) were measured. The new dynamical indices were the value without effort, the characteristic time and the amplitude (gain) of the HR and VO 2 response to the effort. The gain of HR was moderately to strongly associated with other performance indices, while the gain for VO 2 increased with training and decreased with deconditioning with an effect size slightly higher than VO 2 max. Dynamical analysis performed on the first 2/3 of the effort tests showed similar patterns than the analysis of the entire effort tests, which could be useful to assess individuals who cannot perform full effort tests. In conclusion, the dynamical analysis of HR and VO 2 obtained during effort test, especially through the estimation of the gain, provides a good characterization of physical performance, robust to less stringent effort test conditions.</abstract><pub>Nature Publishing Group</pub><doi>10.1038/s41598-020-69218-1</doi><orcidid>https://orcid.org/0000-0002-2155-0816</orcidid><orcidid>https://orcid.org/0000-0002-2155-0816</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2045-2322 |
ispartof | Scientific reports, 2020-07, Vol.10 (1) |
issn | 2045-2322 2045-2322 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_04585902v1 |
source | Nature Free; DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry; Springer Nature OA Free Journals |
subjects | Life Sciences |
title | Validity of dynamical analysis to characterize heart rate and oxygen consumption during effort tests |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T14%3A24%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Validity%20of%20dynamical%20analysis%20to%20characterize%20heart%20rate%20and%20oxygen%20consumption%20during%20effort%20tests&rft.jtitle=Scientific%20reports&rft.au=Mongin,%20D.&rft.date=2020-07-24&rft.volume=10&rft.issue=1&rft.issn=2045-2322&rft.eissn=2045-2322&rft_id=info:doi/10.1038/s41598-020-69218-1&rft_dat=%3Chal%3Eoai_HAL_hal_04585902v1%3C/hal%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |