Performance of an Empty Dryer Electrically Heated by Natural and Mixed Convection
In this paper, we report an experimental study on an empty dryer. The device under is an indirect dryer electrically heated. The focus is made on the thermal and fluid behavior in such systems without considering the drying process. Thus, the temperature and fluid velocity profiles are presented in...
Gespeichert in:
Veröffentlicht in: | International energy journal 2022-03, Vol.22 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | International energy journal |
container_volume | 22 |
creator | Abid, Cherifa Adjmi, Samah |
description | In this paper, we report an experimental study on an empty dryer. The device under is an indirect dryer electrically heated. The focus is made on the thermal and fluid behavior in such systems without considering the drying process. Thus, the temperature and fluid velocity profiles are presented in order to determine the fluid flow and the thermal profiles inside the different parts of the dryer in the situations of natural and mixed convection in order to describe and allow a better comprehension of the heat and fluid flow patterns inside a dryer. The enthalpy balances lead to the determination of the most efficient zone in the dryer, this latter is located at 2/3 of its length. |
format | Article |
fullrecord | <record><control><sourceid>hal</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_03985769v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_HAL_hal_03985769v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-h119t-abfa18a736d5b169129041ba4e34391720d393efd03d7a0c4e2911987c96c43c3</originalsourceid><addsrcrecordid>eNotjM1qhDAURrNoocN03iHbLoRcrxqzHKytBfsHM9CdXJPIWKIOMR3q29fSrj44nPNdsQ2kgJGE_OOG7eb5UwgBIFLI0w17f7O-m_xAo7Z86jiNvBzOYeH3frGel87q4HtNzi28shSs4e3CXyh8eXKrbfhz_73CYhovq9pP4y277sjNdve_W3Z8KA9FFdWvj0_Fvo5OACpE1HYEOUnMTNpCpiBWIoGWEosJKpCxMKjQdkagkSR0YmO1hrnUKtMJatyyu7_fE7nm7PuB_NJM1DfVvm5-mUCVpzJTF8AfsHdMHA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Performance of an Empty Dryer Electrically Heated by Natural and Mixed Convection</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Abid, Cherifa ; Adjmi, Samah</creator><creatorcontrib>Abid, Cherifa ; Adjmi, Samah</creatorcontrib><description>In this paper, we report an experimental study on an empty dryer. The device under is an indirect dryer electrically heated. The focus is made on the thermal and fluid behavior in such systems without considering the drying process. Thus, the temperature and fluid velocity profiles are presented in order to determine the fluid flow and the thermal profiles inside the different parts of the dryer in the situations of natural and mixed convection in order to describe and allow a better comprehension of the heat and fluid flow patterns inside a dryer. The enthalpy balances lead to the determination of the most efficient zone in the dryer, this latter is located at 2/3 of its length.</description><identifier>ISSN: 1513-718X</identifier><language>eng</language><publisher>RERIC, Asian Institute of Technology</publisher><subject>Physics</subject><ispartof>International energy journal, 2022-03, Vol.22</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0001-5209-0704</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881</link.rule.ids><backlink>$$Uhttps://hal.science/hal-03985769$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Abid, Cherifa</creatorcontrib><creatorcontrib>Adjmi, Samah</creatorcontrib><title>Performance of an Empty Dryer Electrically Heated by Natural and Mixed Convection</title><title>International energy journal</title><description>In this paper, we report an experimental study on an empty dryer. The device under is an indirect dryer electrically heated. The focus is made on the thermal and fluid behavior in such systems without considering the drying process. Thus, the temperature and fluid velocity profiles are presented in order to determine the fluid flow and the thermal profiles inside the different parts of the dryer in the situations of natural and mixed convection in order to describe and allow a better comprehension of the heat and fluid flow patterns inside a dryer. The enthalpy balances lead to the determination of the most efficient zone in the dryer, this latter is located at 2/3 of its length.</description><subject>Physics</subject><issn>1513-718X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNotjM1qhDAURrNoocN03iHbLoRcrxqzHKytBfsHM9CdXJPIWKIOMR3q29fSrj44nPNdsQ2kgJGE_OOG7eb5UwgBIFLI0w17f7O-m_xAo7Z86jiNvBzOYeH3frGel87q4HtNzi28shSs4e3CXyh8eXKrbfhz_73CYhovq9pP4y277sjNdve_W3Z8KA9FFdWvj0_Fvo5OACpE1HYEOUnMTNpCpiBWIoGWEosJKpCxMKjQdkagkSR0YmO1hrnUKtMJatyyu7_fE7nm7PuB_NJM1DfVvm5-mUCVpzJTF8AfsHdMHA</recordid><startdate>20220301</startdate><enddate>20220301</enddate><creator>Abid, Cherifa</creator><creator>Adjmi, Samah</creator><general>RERIC, Asian Institute of Technology</general><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0001-5209-0704</orcidid></search><sort><creationdate>20220301</creationdate><title>Performance of an Empty Dryer Electrically Heated by Natural and Mixed Convection</title><author>Abid, Cherifa ; Adjmi, Samah</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-h119t-abfa18a736d5b169129041ba4e34391720d393efd03d7a0c4e2911987c96c43c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Physics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abid, Cherifa</creatorcontrib><creatorcontrib>Adjmi, Samah</creatorcontrib><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>International energy journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abid, Cherifa</au><au>Adjmi, Samah</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance of an Empty Dryer Electrically Heated by Natural and Mixed Convection</atitle><jtitle>International energy journal</jtitle><date>2022-03-01</date><risdate>2022</risdate><volume>22</volume><issn>1513-718X</issn><abstract>In this paper, we report an experimental study on an empty dryer. The device under is an indirect dryer electrically heated. The focus is made on the thermal and fluid behavior in such systems without considering the drying process. Thus, the temperature and fluid velocity profiles are presented in order to determine the fluid flow and the thermal profiles inside the different parts of the dryer in the situations of natural and mixed convection in order to describe and allow a better comprehension of the heat and fluid flow patterns inside a dryer. The enthalpy balances lead to the determination of the most efficient zone in the dryer, this latter is located at 2/3 of its length.</abstract><pub>RERIC, Asian Institute of Technology</pub><orcidid>https://orcid.org/0000-0001-5209-0704</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1513-718X |
ispartof | International energy journal, 2022-03, Vol.22 |
issn | 1513-718X |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_03985769v1 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Physics |
title | Performance of an Empty Dryer Electrically Heated by Natural and Mixed Convection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T00%3A40%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20of%20an%20Empty%20Dryer%20Electrically%20Heated%20by%20Natural%20and%20Mixed%20Convection&rft.jtitle=International%20energy%20journal&rft.au=Abid,%20Cherifa&rft.date=2022-03-01&rft.volume=22&rft.issn=1513-718X&rft_id=info:doi/&rft_dat=%3Chal%3Eoai_HAL_hal_03985769v1%3C/hal%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |