Parallel and serial processes in number-to-quantity conversion

Converting a multi-digit number to quantity requires processing not only the digits but also the number's decimal structure, thus raising several issues. First, are all the digits processed in parallel, or serially from left to right? Second, given that the same digit at different places can re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cognition 2020-11, Vol.204, p.104387-104387, Article 104387
Hauptverfasser: Dotan, Dror, Dehaene, Stanislas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 104387
container_issue
container_start_page 104387
container_title Cognition
container_volume 204
creator Dotan, Dror
Dehaene, Stanislas
description Converting a multi-digit number to quantity requires processing not only the digits but also the number's decimal structure, thus raising several issues. First, are all the digits processed in parallel, or serially from left to right? Second, given that the same digit at different places can represent different quantities (e.g., “2” can mean 2, 20, etc.), how is each digit assigned to its correct decimal role? We presented participants with two-digit numbers and asked them to point at the corresponding locations on a number line, while we recorded their pointing trajectory. Crucially, on some trials, the decade and unit digits did not appear simultaneously. When the decade digit was delayed, the decade effect on finger movement was delayed by the same amount. However, a lag in presenting the unit digit delayed the unit effect by 35 ms less than the lag duration, a pattern reminiscent of the psychological refractory period, indicating an idle time window of 35 ms in the units processing pathway. When a lag transiently caused a display of just one digit on screen, the unit effect increased and the decade effect decreased, suggesting errors in binding digits to decimal roles. We propose that a serial bottleneck is imposed by the creation of a syntactic frame for the multidigit number, a process launched by the leftmost digit. All other stages, including the binding of digits to decimal roles, quantification, and merging them into a whole-number quantity, appear to operate in parallel across digits, suggesting a remarkable degree of parallelism in expert readers. •Subjects saw 2-digit numbers and pointed to their position on a number line.•Deviations from 1:10 weighting of the digits suggest they were sometimes swapped.•A delay of Δt in the unit digit onset delayed the finger trajectory by only Δt-35 ms.•This PRP-like pattern suggests that the unit processing awaits a bottleneck process.•The bottleneck may be a “syntactic frame” that binds digits to their decimal roles.
doi_str_mv 10.1016/j.cognition.2020.104387
format Article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_03492432v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0010027720302067</els_id><sourcerecordid>2476175090</sourcerecordid><originalsourceid>FETCH-LOGICAL-c482t-362ef0a601eed1f0688a4c0dbd6eb0f634d24931b8d51d716da23478ef6439fb3</originalsourceid><addsrcrecordid>eNqFkUtvEzEUhS0EoqHwF2AkNrCY9PoR27NBiqqWIkWiC1hbHvsOOJrYrT0Tqf8eR1OyYMPqSkfffZx7CPlAYU2Byqv92qVfMUwhxTUDdlIF1-oFWVGteKs01y_JCoBCC0ypC_KmlD0ACKb0a3LBmRSbDYMV-XJvsx1HHBsbfVMwBzs2Dzk5LAVLE2IT50OPuZ1S-zjbOIXpqXEpHjGXuvwteTXYseC753pJft7e_Li-a3ffv3673u5aJzSbWi4ZDmAlUERPB5BaW-HA915iD4PkwjPRcdprv6FeUekt40JpHKTg3dDzS_J5mfvbjuYhh4PNTybZYO62O3PSgIuOCc6OtLKfFrbaeJyxTOYQisNxtBHTXAwTjIOUqlMV_fgPuk9zjtVJpZSkagMdVEotlMuplIzD-QIK5hSH2ZtzHOYUh1niqJ3vn-fP_QH9ue_v_yuwXQCszzsGzKa4gNGhDxndZHwK_13yB7mfng0</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2476175090</pqid></control><display><type>article</type><title>Parallel and serial processes in number-to-quantity conversion</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Dotan, Dror ; Dehaene, Stanislas</creator><creatorcontrib>Dotan, Dror ; Dehaene, Stanislas</creatorcontrib><description>Converting a multi-digit number to quantity requires processing not only the digits but also the number's decimal structure, thus raising several issues. First, are all the digits processed in parallel, or serially from left to right? Second, given that the same digit at different places can represent different quantities (e.g., “2” can mean 2, 20, etc.), how is each digit assigned to its correct decimal role? We presented participants with two-digit numbers and asked them to point at the corresponding locations on a number line, while we recorded their pointing trajectory. Crucially, on some trials, the decade and unit digits did not appear simultaneously. When the decade digit was delayed, the decade effect on finger movement was delayed by the same amount. However, a lag in presenting the unit digit delayed the unit effect by 35 ms less than the lag duration, a pattern reminiscent of the psychological refractory period, indicating an idle time window of 35 ms in the units processing pathway. When a lag transiently caused a display of just one digit on screen, the unit effect increased and the decade effect decreased, suggesting errors in binding digits to decimal roles. We propose that a serial bottleneck is imposed by the creation of a syntactic frame for the multidigit number, a process launched by the leftmost digit. All other stages, including the binding of digits to decimal roles, quantification, and merging them into a whole-number quantity, appear to operate in parallel across digits, suggesting a remarkable degree of parallelism in expert readers. •Subjects saw 2-digit numbers and pointed to their position on a number line.•Deviations from 1:10 weighting of the digits suggest they were sometimes swapped.•A delay of Δt in the unit digit onset delayed the finger trajectory by only Δt-35 ms.•This PRP-like pattern suggests that the unit processing awaits a bottleneck process.•The bottleneck may be a “syntactic frame” that binds digits to their decimal roles.</description><identifier>ISSN: 0010-0277</identifier><identifier>EISSN: 1873-7838</identifier><identifier>DOI: 10.1016/j.cognition.2020.104387</identifier><identifier>PMID: 32645520</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Cognitive science ; Delayed ; Measurement ; Mental number line ; Multi-digit numbers ; Number representation ; Number syntax ; Numbers ; Psychological refractory period ; Serial and parallel processing</subject><ispartof>Cognition, 2020-11, Vol.204, p.104387-104387, Article 104387</ispartof><rights>2020 Elsevier B.V.</rights><rights>Copyright © 2020 Elsevier B.V. All rights reserved.</rights><rights>Copyright Elsevier Science Ltd. Nov 2020</rights><rights>Attribution - NonCommercial</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c482t-362ef0a601eed1f0688a4c0dbd6eb0f634d24931b8d51d716da23478ef6439fb3</citedby><cites>FETCH-LOGICAL-c482t-362ef0a601eed1f0688a4c0dbd6eb0f634d24931b8d51d716da23478ef6439fb3</cites><orcidid>0000-0002-7418-8275</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.cognition.2020.104387$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32645520$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-03492432$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Dotan, Dror</creatorcontrib><creatorcontrib>Dehaene, Stanislas</creatorcontrib><title>Parallel and serial processes in number-to-quantity conversion</title><title>Cognition</title><addtitle>Cognition</addtitle><description>Converting a multi-digit number to quantity requires processing not only the digits but also the number's decimal structure, thus raising several issues. First, are all the digits processed in parallel, or serially from left to right? Second, given that the same digit at different places can represent different quantities (e.g., “2” can mean 2, 20, etc.), how is each digit assigned to its correct decimal role? We presented participants with two-digit numbers and asked them to point at the corresponding locations on a number line, while we recorded their pointing trajectory. Crucially, on some trials, the decade and unit digits did not appear simultaneously. When the decade digit was delayed, the decade effect on finger movement was delayed by the same amount. However, a lag in presenting the unit digit delayed the unit effect by 35 ms less than the lag duration, a pattern reminiscent of the psychological refractory period, indicating an idle time window of 35 ms in the units processing pathway. When a lag transiently caused a display of just one digit on screen, the unit effect increased and the decade effect decreased, suggesting errors in binding digits to decimal roles. We propose that a serial bottleneck is imposed by the creation of a syntactic frame for the multidigit number, a process launched by the leftmost digit. All other stages, including the binding of digits to decimal roles, quantification, and merging them into a whole-number quantity, appear to operate in parallel across digits, suggesting a remarkable degree of parallelism in expert readers. •Subjects saw 2-digit numbers and pointed to their position on a number line.•Deviations from 1:10 weighting of the digits suggest they were sometimes swapped.•A delay of Δt in the unit digit onset delayed the finger trajectory by only Δt-35 ms.•This PRP-like pattern suggests that the unit processing awaits a bottleneck process.•The bottleneck may be a “syntactic frame” that binds digits to their decimal roles.</description><subject>Cognitive science</subject><subject>Delayed</subject><subject>Measurement</subject><subject>Mental number line</subject><subject>Multi-digit numbers</subject><subject>Number representation</subject><subject>Number syntax</subject><subject>Numbers</subject><subject>Psychological refractory period</subject><subject>Serial and parallel processing</subject><issn>0010-0277</issn><issn>1873-7838</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkUtvEzEUhS0EoqHwF2AkNrCY9PoR27NBiqqWIkWiC1hbHvsOOJrYrT0Tqf8eR1OyYMPqSkfffZx7CPlAYU2Byqv92qVfMUwhxTUDdlIF1-oFWVGteKs01y_JCoBCC0ypC_KmlD0ACKb0a3LBmRSbDYMV-XJvsx1HHBsbfVMwBzs2Dzk5LAVLE2IT50OPuZ1S-zjbOIXpqXEpHjGXuvwteTXYseC753pJft7e_Li-a3ffv3673u5aJzSbWi4ZDmAlUERPB5BaW-HA915iD4PkwjPRcdprv6FeUekt40JpHKTg3dDzS_J5mfvbjuYhh4PNTybZYO62O3PSgIuOCc6OtLKfFrbaeJyxTOYQisNxtBHTXAwTjIOUqlMV_fgPuk9zjtVJpZSkagMdVEotlMuplIzD-QIK5hSH2ZtzHOYUh1niqJ3vn-fP_QH9ue_v_yuwXQCszzsGzKa4gNGhDxndZHwK_13yB7mfng0</recordid><startdate>20201101</startdate><enddate>20201101</enddate><creator>Dotan, Dror</creator><creator>Dehaene, Stanislas</creator><general>Elsevier B.V</general><general>Elsevier Science Ltd</general><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>8BJ</scope><scope>FQK</scope><scope>JBE</scope><scope>7X8</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0002-7418-8275</orcidid></search><sort><creationdate>20201101</creationdate><title>Parallel and serial processes in number-to-quantity conversion</title><author>Dotan, Dror ; Dehaene, Stanislas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c482t-362ef0a601eed1f0688a4c0dbd6eb0f634d24931b8d51d716da23478ef6439fb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Cognitive science</topic><topic>Delayed</topic><topic>Measurement</topic><topic>Mental number line</topic><topic>Multi-digit numbers</topic><topic>Number representation</topic><topic>Number syntax</topic><topic>Numbers</topic><topic>Psychological refractory period</topic><topic>Serial and parallel processing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dotan, Dror</creatorcontrib><creatorcontrib>Dehaene, Stanislas</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>International Bibliography of the Social Sciences (IBSS)</collection><collection>International Bibliography of the Social Sciences</collection><collection>International Bibliography of the Social Sciences</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Cognition</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dotan, Dror</au><au>Dehaene, Stanislas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Parallel and serial processes in number-to-quantity conversion</atitle><jtitle>Cognition</jtitle><addtitle>Cognition</addtitle><date>2020-11-01</date><risdate>2020</risdate><volume>204</volume><spage>104387</spage><epage>104387</epage><pages>104387-104387</pages><artnum>104387</artnum><issn>0010-0277</issn><eissn>1873-7838</eissn><abstract>Converting a multi-digit number to quantity requires processing not only the digits but also the number's decimal structure, thus raising several issues. First, are all the digits processed in parallel, or serially from left to right? Second, given that the same digit at different places can represent different quantities (e.g., “2” can mean 2, 20, etc.), how is each digit assigned to its correct decimal role? We presented participants with two-digit numbers and asked them to point at the corresponding locations on a number line, while we recorded their pointing trajectory. Crucially, on some trials, the decade and unit digits did not appear simultaneously. When the decade digit was delayed, the decade effect on finger movement was delayed by the same amount. However, a lag in presenting the unit digit delayed the unit effect by 35 ms less than the lag duration, a pattern reminiscent of the psychological refractory period, indicating an idle time window of 35 ms in the units processing pathway. When a lag transiently caused a display of just one digit on screen, the unit effect increased and the decade effect decreased, suggesting errors in binding digits to decimal roles. We propose that a serial bottleneck is imposed by the creation of a syntactic frame for the multidigit number, a process launched by the leftmost digit. All other stages, including the binding of digits to decimal roles, quantification, and merging them into a whole-number quantity, appear to operate in parallel across digits, suggesting a remarkable degree of parallelism in expert readers. •Subjects saw 2-digit numbers and pointed to their position on a number line.•Deviations from 1:10 weighting of the digits suggest they were sometimes swapped.•A delay of Δt in the unit digit onset delayed the finger trajectory by only Δt-35 ms.•This PRP-like pattern suggests that the unit processing awaits a bottleneck process.•The bottleneck may be a “syntactic frame” that binds digits to their decimal roles.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>32645520</pmid><doi>10.1016/j.cognition.2020.104387</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-7418-8275</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0010-0277
ispartof Cognition, 2020-11, Vol.204, p.104387-104387, Article 104387
issn 0010-0277
1873-7838
language eng
recordid cdi_hal_primary_oai_HAL_hal_03492432v1
source ScienceDirect Journals (5 years ago - present)
subjects Cognitive science
Delayed
Measurement
Mental number line
Multi-digit numbers
Number representation
Number syntax
Numbers
Psychological refractory period
Serial and parallel processing
title Parallel and serial processes in number-to-quantity conversion
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T08%3A16%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Parallel%20and%20serial%20processes%20in%20number-to-quantity%20conversion&rft.jtitle=Cognition&rft.au=Dotan,%20Dror&rft.date=2020-11-01&rft.volume=204&rft.spage=104387&rft.epage=104387&rft.pages=104387-104387&rft.artnum=104387&rft.issn=0010-0277&rft.eissn=1873-7838&rft_id=info:doi/10.1016/j.cognition.2020.104387&rft_dat=%3Cproquest_hal_p%3E2476175090%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2476175090&rft_id=info:pmid/32645520&rft_els_id=S0010027720302067&rfr_iscdi=true