Posterior interosseous nerve of the elbow at the arcade of Frohse: Ultrasound appearance in asymptomatic subjects

To assess the normal values of the antero-posterior (AP) diameter of the posterior interosseous nerve (PIN) of the elbow as it passes beneath the arcade of Frohse and to search for PIN-diameter differences between the upstream, entry point and downstream of the arcade. Thirty asymptomatic patients p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostic and interventional imaging 2019-09, Vol.100 (9), p.521-525
Hauptverfasser: Ceri, T., Podda, A., Behr, J., Brumpt, E., Alilet, M., Aubry, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 525
container_issue 9
container_start_page 521
container_title Diagnostic and interventional imaging
container_volume 100
creator Ceri, T.
Podda, A.
Behr, J.
Brumpt, E.
Alilet, M.
Aubry, S.
description To assess the normal values of the antero-posterior (AP) diameter of the posterior interosseous nerve (PIN) of the elbow as it passes beneath the arcade of Frohse and to search for PIN-diameter differences between the upstream, entry point and downstream of the arcade. Thirty asymptomatic patients prospectively underwent bilateral B-mode ultrasound of the PIN of the elbow. There were 15 men and 15 women with a mean age of 30.2±5.31 (SD) years (range: 26–43 years). Of these, 23 patients were right-handers (23/30; 77%) and 7 were left handers (7/30; 23%). AP diameter of the PIN was measured in long axis at three different locations including the entry point of the arcade, 5-mm upstream and 5-mm downstream the arcade. A comparison between the three measurements was performed using paired t-test. The mean AP diameters of the PIN were 0.83±0.21 (SD) mm (range: 0.43–1.31mm), 0.6±0.17 (SD) mm (range: 0.29–1.16mm) and 0.49±0.13 (SD) mm (range: 0.26–0.86mm) at 5-mm upstream, entry point of the arcade and 5-mm downstream the arcade of Frohse, respectively. Significant drops in PIN diameter were found between upstream and the arcade (−0.23mm; 27%; P
doi_str_mv 10.1016/j.diii.2019.03.007
format Article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_03487680v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2211568419300646</els_id><sourcerecordid>2202203474</sourcerecordid><originalsourceid>FETCH-LOGICAL-c434t-dac1c573d62e526fe74b8a6b5a99fce319353eccf84c9d113d71a3e5a7f008f53</originalsourceid><addsrcrecordid>eNp9kU9PHSEUxUljU431C3RhWOriTWFg_hk35kVrk5e0i7omd-BOHi8zwwjMM357GZ81riQkXOB3D-EcQn5wlnHGy5-7zFhrs5zxJmMiY6z6Qk7ynPNVUdby6EN9TM5C2LE0ytQo5TdyLFgjirrkJ-TxrwsRvXWe2jEVLgR0c6Aj-j1S19G4RYp9654oxNcNeA3m9erOu23AK_rQRw_BzaOhME0IHkaNSY5CeB6m6AaIVtMwtzvUMXwnXzvoA569rafk4e723_p-tfnz6_f6ZrPSUsi4MqC5LiphyhyLvOywkm0NZVtA03QaBU8_EKh1V0vdGM6FqTgILKDqGKu7QpySy4PuFno1eTuAf1YOrLq_2ajljAlZV2XN9jyxFwd28u5xxhDVYIPGvodxcUPlOUtTyEomND-gevHKY_euzZlaklE7tSSjlmTSGyolk5rO3_TndkDz3vI_hwRcHwBMjuwtehW0xWSjsT6Zpoyzn-m_ANNnoB8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2202203474</pqid></control><display><type>article</type><title>Posterior interosseous nerve of the elbow at the arcade of Frohse: Ultrasound appearance in asymptomatic subjects</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Ceri, T. ; Podda, A. ; Behr, J. ; Brumpt, E. ; Alilet, M. ; Aubry, S.</creator><creatorcontrib>Ceri, T. ; Podda, A. ; Behr, J. ; Brumpt, E. ; Alilet, M. ; Aubry, S.</creatorcontrib><description>To assess the normal values of the antero-posterior (AP) diameter of the posterior interosseous nerve (PIN) of the elbow as it passes beneath the arcade of Frohse and to search for PIN-diameter differences between the upstream, entry point and downstream of the arcade. Thirty asymptomatic patients prospectively underwent bilateral B-mode ultrasound of the PIN of the elbow. There were 15 men and 15 women with a mean age of 30.2±5.31 (SD) years (range: 26–43 years). Of these, 23 patients were right-handers (23/30; 77%) and 7 were left handers (7/30; 23%). AP diameter of the PIN was measured in long axis at three different locations including the entry point of the arcade, 5-mm upstream and 5-mm downstream the arcade. A comparison between the three measurements was performed using paired t-test. The mean AP diameters of the PIN were 0.83±0.21 (SD) mm (range: 0.43–1.31mm), 0.6±0.17 (SD) mm (range: 0.29–1.16mm) and 0.49±0.13 (SD) mm (range: 0.26–0.86mm) at 5-mm upstream, entry point of the arcade and 5-mm downstream the arcade of Frohse, respectively. Significant drops in PIN diameter were found between upstream and the arcade (−0.23mm; 27%; P&lt;0.001), between the arcade and downstream (−0.11mm; 17%; P&lt;0.001), and between upstream and downstream the arcade (−0.34mm; 40%; P&lt;0.001). Disparity in AP diameter of the PIN of the elbow in the arcade of Frohse is a normal finding and should not be erroneously interpreted as entrapment when present alone.</description><identifier>ISSN: 2211-5684</identifier><identifier>EISSN: 2211-5684</identifier><identifier>DOI: 10.1016/j.diii.2019.03.007</identifier><identifier>PMID: 30935861</identifier><language>eng</language><publisher>France: Elsevier Masson SAS</publisher><subject>Adult ; Anatomic studies ; Arcade of Frohse ; Asymptomatic Diseases ; Elbow - diagnostic imaging ; Female ; Humans ; Life Sciences ; Male ; Nerve Compression Syndromes ; Peripheral Nervous System Diseases ; Posterior inter-osseous nerve syndrome ; Prospective Studies ; Radial Nerve - anatomy &amp; histology ; Radial Nerve - diagnostic imaging ; Supinator muscle ; Ultrasonography ; Ultrasound</subject><ispartof>Diagnostic and interventional imaging, 2019-09, Vol.100 (9), p.521-525</ispartof><rights>2019 Société française de radiologie</rights><rights>Copyright © 2019 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.</rights><rights>Attribution - NonCommercial</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c434t-dac1c573d62e526fe74b8a6b5a99fce319353eccf84c9d113d71a3e5a7f008f53</citedby><cites>FETCH-LOGICAL-c434t-dac1c573d62e526fe74b8a6b5a99fce319353eccf84c9d113d71a3e5a7f008f53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30935861$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-03487680$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Ceri, T.</creatorcontrib><creatorcontrib>Podda, A.</creatorcontrib><creatorcontrib>Behr, J.</creatorcontrib><creatorcontrib>Brumpt, E.</creatorcontrib><creatorcontrib>Alilet, M.</creatorcontrib><creatorcontrib>Aubry, S.</creatorcontrib><title>Posterior interosseous nerve of the elbow at the arcade of Frohse: Ultrasound appearance in asymptomatic subjects</title><title>Diagnostic and interventional imaging</title><addtitle>Diagn Interv Imaging</addtitle><description>To assess the normal values of the antero-posterior (AP) diameter of the posterior interosseous nerve (PIN) of the elbow as it passes beneath the arcade of Frohse and to search for PIN-diameter differences between the upstream, entry point and downstream of the arcade. Thirty asymptomatic patients prospectively underwent bilateral B-mode ultrasound of the PIN of the elbow. There were 15 men and 15 women with a mean age of 30.2±5.31 (SD) years (range: 26–43 years). Of these, 23 patients were right-handers (23/30; 77%) and 7 were left handers (7/30; 23%). AP diameter of the PIN was measured in long axis at three different locations including the entry point of the arcade, 5-mm upstream and 5-mm downstream the arcade. A comparison between the three measurements was performed using paired t-test. The mean AP diameters of the PIN were 0.83±0.21 (SD) mm (range: 0.43–1.31mm), 0.6±0.17 (SD) mm (range: 0.29–1.16mm) and 0.49±0.13 (SD) mm (range: 0.26–0.86mm) at 5-mm upstream, entry point of the arcade and 5-mm downstream the arcade of Frohse, respectively. Significant drops in PIN diameter were found between upstream and the arcade (−0.23mm; 27%; P&lt;0.001), between the arcade and downstream (−0.11mm; 17%; P&lt;0.001), and between upstream and downstream the arcade (−0.34mm; 40%; P&lt;0.001). Disparity in AP diameter of the PIN of the elbow in the arcade of Frohse is a normal finding and should not be erroneously interpreted as entrapment when present alone.</description><subject>Adult</subject><subject>Anatomic studies</subject><subject>Arcade of Frohse</subject><subject>Asymptomatic Diseases</subject><subject>Elbow - diagnostic imaging</subject><subject>Female</subject><subject>Humans</subject><subject>Life Sciences</subject><subject>Male</subject><subject>Nerve Compression Syndromes</subject><subject>Peripheral Nervous System Diseases</subject><subject>Posterior inter-osseous nerve syndrome</subject><subject>Prospective Studies</subject><subject>Radial Nerve - anatomy &amp; histology</subject><subject>Radial Nerve - diagnostic imaging</subject><subject>Supinator muscle</subject><subject>Ultrasonography</subject><subject>Ultrasound</subject><issn>2211-5684</issn><issn>2211-5684</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kU9PHSEUxUljU431C3RhWOriTWFg_hk35kVrk5e0i7omd-BOHi8zwwjMM357GZ81riQkXOB3D-EcQn5wlnHGy5-7zFhrs5zxJmMiY6z6Qk7ynPNVUdby6EN9TM5C2LE0ytQo5TdyLFgjirrkJ-TxrwsRvXWe2jEVLgR0c6Aj-j1S19G4RYp9654oxNcNeA3m9erOu23AK_rQRw_BzaOhME0IHkaNSY5CeB6m6AaIVtMwtzvUMXwnXzvoA569rafk4e723_p-tfnz6_f6ZrPSUsi4MqC5LiphyhyLvOywkm0NZVtA03QaBU8_EKh1V0vdGM6FqTgILKDqGKu7QpySy4PuFno1eTuAf1YOrLq_2ajljAlZV2XN9jyxFwd28u5xxhDVYIPGvodxcUPlOUtTyEomND-gevHKY_euzZlaklE7tSSjlmTSGyolk5rO3_TndkDz3vI_hwRcHwBMjuwtehW0xWSjsT6Zpoyzn-m_ANNnoB8</recordid><startdate>20190901</startdate><enddate>20190901</enddate><creator>Ceri, T.</creator><creator>Podda, A.</creator><creator>Behr, J.</creator><creator>Brumpt, E.</creator><creator>Alilet, M.</creator><creator>Aubry, S.</creator><general>Elsevier Masson SAS</general><general>Elsevier</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>1XC</scope><scope>VOOES</scope></search><sort><creationdate>20190901</creationdate><title>Posterior interosseous nerve of the elbow at the arcade of Frohse: Ultrasound appearance in asymptomatic subjects</title><author>Ceri, T. ; Podda, A. ; Behr, J. ; Brumpt, E. ; Alilet, M. ; Aubry, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c434t-dac1c573d62e526fe74b8a6b5a99fce319353eccf84c9d113d71a3e5a7f008f53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Adult</topic><topic>Anatomic studies</topic><topic>Arcade of Frohse</topic><topic>Asymptomatic Diseases</topic><topic>Elbow - diagnostic imaging</topic><topic>Female</topic><topic>Humans</topic><topic>Life Sciences</topic><topic>Male</topic><topic>Nerve Compression Syndromes</topic><topic>Peripheral Nervous System Diseases</topic><topic>Posterior inter-osseous nerve syndrome</topic><topic>Prospective Studies</topic><topic>Radial Nerve - anatomy &amp; histology</topic><topic>Radial Nerve - diagnostic imaging</topic><topic>Supinator muscle</topic><topic>Ultrasonography</topic><topic>Ultrasound</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ceri, T.</creatorcontrib><creatorcontrib>Podda, A.</creatorcontrib><creatorcontrib>Behr, J.</creatorcontrib><creatorcontrib>Brumpt, E.</creatorcontrib><creatorcontrib>Alilet, M.</creatorcontrib><creatorcontrib>Aubry, S.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Diagnostic and interventional imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ceri, T.</au><au>Podda, A.</au><au>Behr, J.</au><au>Brumpt, E.</au><au>Alilet, M.</au><au>Aubry, S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Posterior interosseous nerve of the elbow at the arcade of Frohse: Ultrasound appearance in asymptomatic subjects</atitle><jtitle>Diagnostic and interventional imaging</jtitle><addtitle>Diagn Interv Imaging</addtitle><date>2019-09-01</date><risdate>2019</risdate><volume>100</volume><issue>9</issue><spage>521</spage><epage>525</epage><pages>521-525</pages><issn>2211-5684</issn><eissn>2211-5684</eissn><abstract>To assess the normal values of the antero-posterior (AP) diameter of the posterior interosseous nerve (PIN) of the elbow as it passes beneath the arcade of Frohse and to search for PIN-diameter differences between the upstream, entry point and downstream of the arcade. Thirty asymptomatic patients prospectively underwent bilateral B-mode ultrasound of the PIN of the elbow. There were 15 men and 15 women with a mean age of 30.2±5.31 (SD) years (range: 26–43 years). Of these, 23 patients were right-handers (23/30; 77%) and 7 were left handers (7/30; 23%). AP diameter of the PIN was measured in long axis at three different locations including the entry point of the arcade, 5-mm upstream and 5-mm downstream the arcade. A comparison between the three measurements was performed using paired t-test. The mean AP diameters of the PIN were 0.83±0.21 (SD) mm (range: 0.43–1.31mm), 0.6±0.17 (SD) mm (range: 0.29–1.16mm) and 0.49±0.13 (SD) mm (range: 0.26–0.86mm) at 5-mm upstream, entry point of the arcade and 5-mm downstream the arcade of Frohse, respectively. Significant drops in PIN diameter were found between upstream and the arcade (−0.23mm; 27%; P&lt;0.001), between the arcade and downstream (−0.11mm; 17%; P&lt;0.001), and between upstream and downstream the arcade (−0.34mm; 40%; P&lt;0.001). Disparity in AP diameter of the PIN of the elbow in the arcade of Frohse is a normal finding and should not be erroneously interpreted as entrapment when present alone.</abstract><cop>France</cop><pub>Elsevier Masson SAS</pub><pmid>30935861</pmid><doi>10.1016/j.diii.2019.03.007</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2211-5684
ispartof Diagnostic and interventional imaging, 2019-09, Vol.100 (9), p.521-525
issn 2211-5684
2211-5684
language eng
recordid cdi_hal_primary_oai_HAL_hal_03487680v1
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Adult
Anatomic studies
Arcade of Frohse
Asymptomatic Diseases
Elbow - diagnostic imaging
Female
Humans
Life Sciences
Male
Nerve Compression Syndromes
Peripheral Nervous System Diseases
Posterior inter-osseous nerve syndrome
Prospective Studies
Radial Nerve - anatomy & histology
Radial Nerve - diagnostic imaging
Supinator muscle
Ultrasonography
Ultrasound
title Posterior interosseous nerve of the elbow at the arcade of Frohse: Ultrasound appearance in asymptomatic subjects
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T01%3A50%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Posterior%20interosseous%20nerve%20of%20the%20elbow%20at%20the%20arcade%20of%20Frohse:%20Ultrasound%20appearance%20in%20asymptomatic%20subjects&rft.jtitle=Diagnostic%20and%20interventional%20imaging&rft.au=Ceri,%20T.&rft.date=2019-09-01&rft.volume=100&rft.issue=9&rft.spage=521&rft.epage=525&rft.pages=521-525&rft.issn=2211-5684&rft.eissn=2211-5684&rft_id=info:doi/10.1016/j.diii.2019.03.007&rft_dat=%3Cproquest_hal_p%3E2202203474%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2202203474&rft_id=info:pmid/30935861&rft_els_id=S2211568419300646&rfr_iscdi=true