Optimisation of fast quantification of fluorine content using handheld laser induced breakdown spectroscopy

Hydrofluoric acid represents the majority of the industrial applications of fluorine in the world. It is synthetized from fluorite, which is commonly purified by the froth flotation process to attain the high-grades required for hydrofluoric acid production. Besides, in metallic ores such as tungste...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spectrochimica acta. Part B: Atomic spectroscopy 2019-08, Vol.158, p.105628, Article 105628
Hauptverfasser: Foucaud, Y., Fabre, C., Demeusy, B., Filippova, I.V., Filippov, L.O.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 105628
container_title Spectrochimica acta. Part B: Atomic spectroscopy
container_volume 158
creator Foucaud, Y.
Fabre, C.
Demeusy, B.
Filippova, I.V.
Filippov, L.O.
description Hydrofluoric acid represents the majority of the industrial applications of fluorine in the world. It is synthetized from fluorite, which is commonly purified by the froth flotation process to attain the high-grades required for hydrofluoric acid production. Besides, in metallic ores such as tungsten and phosphate ores, fluorite does not represent any added value compared to the extracted metals and is, therefore, considered as a gangue mineral that has to be rejected. In both cases, the fluorine content has to be known precisely in the flotation process as well as in all the industrial applications involving fluorine, to estimate the process efficiency and to optimise the operations. Nevertheless, fluorine quantification is difficult using conventional techniques since it usually includes heavy sample preparation such as dissolution. Though, Laser-Induced Breakdown Spectroscopy (LIBS) provides a multi-element detection that has been successfully used to quantify fluorine using either elementary or CaF molecular bands. Here, rock samples exhibiting a wide range of fluorine contents (from 1.48% to 40.73%) were analysed, the fluorine being mainly comprised in fluorite. These samples corresponded to the products of different flotation tests conducted on the same tungsten-skarn ore. The experimental conditions were optimised to study the two CaF molecular bands, located between 529 and 543 nm, and between 590 and 606 nm, respectively. Systematically, the LIBS emission intensities of the two studied bands were evaluated using the peak areas, which were normalised, averaged over several ablated zones, and correlated with the fluorine content determined by the fluoride-ion sensitive electrode method. The particle size played a key role as significant differences in the LIBS intensities were exhibited between the 10–150 μm and the
doi_str_mv 10.1016/j.sab.2019.05.017
format Article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_03484488v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0584854719300527</els_id><sourcerecordid>2306476739</sourcerecordid><originalsourceid>FETCH-LOGICAL-c402t-e330a8fb7e8fdab93fa590e560ab3c86a9a3c8376174f8e3150a2dcddb7fdc43</originalsourceid><addsrcrecordid>eNp9kE9r3DAUxEVpodukH6A3QU892JEsyZLpKYSmKSzkkrt41p-uNo7kSHJKvn21bGlvPT0YZoY3P4Q-UdJTQserY19g7gdCp56InlD5Bu2okqxjYhRv0Y4IxTsluHyPPpRyJIQMYhA79Hi_1vAUCtSQIk4eeygVP28Qa_DB_JOXLeUQHTYpVhcr3kqIP_EBoj24xeIFiss4RLsZZ_GcHTza9CvisjpTcyomra-X6J2HpbiPf-4Ferj99nBz1-3vv_-4ud53hpOhdo4xAsrP0ilvYZ6YBzERJ0YCMzNqhAnaYXKkknvlGBUEBmusnaW3hrML9OVce4BFrzk8QX7VCYK-u97rk0YYV5wr9UKb9_PZu-b0vLlS9TFtObbv9MDIyOUo2dRc9OwybUnJzv-tpUSf8Oujbvj1Cb8mQjf8LfP1nHFt6UtwWRcTXGx0Qm5ItE3hP-nfpJePqw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2306476739</pqid></control><display><type>article</type><title>Optimisation of fast quantification of fluorine content using handheld laser induced breakdown spectroscopy</title><source>Elsevier ScienceDirect Journals</source><creator>Foucaud, Y. ; Fabre, C. ; Demeusy, B. ; Filippova, I.V. ; Filippov, L.O.</creator><creatorcontrib>Foucaud, Y. ; Fabre, C. ; Demeusy, B. ; Filippova, I.V. ; Filippov, L.O.</creatorcontrib><description>Hydrofluoric acid represents the majority of the industrial applications of fluorine in the world. It is synthetized from fluorite, which is commonly purified by the froth flotation process to attain the high-grades required for hydrofluoric acid production. Besides, in metallic ores such as tungsten and phosphate ores, fluorite does not represent any added value compared to the extracted metals and is, therefore, considered as a gangue mineral that has to be rejected. In both cases, the fluorine content has to be known precisely in the flotation process as well as in all the industrial applications involving fluorine, to estimate the process efficiency and to optimise the operations. Nevertheless, fluorine quantification is difficult using conventional techniques since it usually includes heavy sample preparation such as dissolution. Though, Laser-Induced Breakdown Spectroscopy (LIBS) provides a multi-element detection that has been successfully used to quantify fluorine using either elementary or CaF molecular bands. Here, rock samples exhibiting a wide range of fluorine contents (from 1.48% to 40.73%) were analysed, the fluorine being mainly comprised in fluorite. These samples corresponded to the products of different flotation tests conducted on the same tungsten-skarn ore. The experimental conditions were optimised to study the two CaF molecular bands, located between 529 and 543 nm, and between 590 and 606 nm, respectively. Systematically, the LIBS emission intensities of the two studied bands were evaluated using the peak areas, which were normalised, averaged over several ablated zones, and correlated with the fluorine content determined by the fluoride-ion sensitive electrode method. The particle size played a key role as significant differences in the LIBS intensities were exhibited between the 10–150 μm and the &lt;20 μm powders, with no discernible correlation between the size ranges and signal magnitude. Furthermore, the matrix effects strongly impacted the LIBS intensities, which displayed a non-linear relationship with the fluorine contents: this induced the development of non-linear univariate models that were calculated on 27 training samples and validated on nine testing samples (3:1 ratio). Although non-linear models fitted adequately the experimental data, a multivariate approach considering the two studied CaF bands was adopted to overcome the matrix effects. A formula with linear, quadratic, and interaction terms was generated from the multivariate regression, predicting fluorine contents with R2 = 0.94 and a mean average error of 2.18%F. The developed models demonstrated that a precise and accurate quantification of fluorine is possible using a calibrated handheld LIBS, providing an on-line estimation of the processes efficiency and a real-time adaptation. [Display omitted] •Samples with fluorine content from 1.48% to 40.73% were analysed with handheld LIBS.•Peak areas of two CaF molecular bands were correlated with real fluorine contents.•Reducing the particle size increased the LIBS intensities without any actual correlation.•A non-linear correlation was exhibited between CaF intensity areas and fluorine contents.•Quantification accuracy was improved using multivariate models.</description><identifier>ISSN: 0584-8547</identifier><identifier>EISSN: 1873-3565</identifier><identifier>DOI: 10.1016/j.sab.2019.05.017</identifier><language>eng</language><publisher>Oxford: Elsevier B.V</publisher><subject>Ablation ; Acid production ; Adaptation ; Analytical methods ; Bands ; CaF ; Emission analysis ; Flotation ; Fluorides ; Fluorine ; Fluorite ; Gangue ; Heavy metals ; Hydrofluoric acid ; Industrial applications ; Laser induced breakdown spectroscopy ; Lasers ; LIBS ; Mathematical analysis ; Matrix methods ; Metals ; Minerals ; Molecular bands ; Multivariate analysis ; Multivariate modelling ; Non-linear models ; Normalisation with total light ; Optimization ; Ores ; Particle size ; Phosphates ; Physics ; Regression analysis ; Sample preparation ; Sediment samples ; Spectroscopy ; Spectrum analysis ; Training ; Tungsten</subject><ispartof>Spectrochimica acta. Part B: Atomic spectroscopy, 2019-08, Vol.158, p.105628, Article 105628</ispartof><rights>2019 Elsevier B.V.</rights><rights>Copyright Elsevier BV Aug 2019</rights><rights>Attribution - NonCommercial</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c402t-e330a8fb7e8fdab93fa590e560ab3c86a9a3c8376174f8e3150a2dcddb7fdc43</citedby><cites>FETCH-LOGICAL-c402t-e330a8fb7e8fdab93fa590e560ab3c86a9a3c8376174f8e3150a2dcddb7fdc43</cites><orcidid>0000-0001-8627-4050 ; 0000-0002-8846-4218</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0584854719300527$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,776,780,881,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://hal.science/hal-03484488$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Foucaud, Y.</creatorcontrib><creatorcontrib>Fabre, C.</creatorcontrib><creatorcontrib>Demeusy, B.</creatorcontrib><creatorcontrib>Filippova, I.V.</creatorcontrib><creatorcontrib>Filippov, L.O.</creatorcontrib><title>Optimisation of fast quantification of fluorine content using handheld laser induced breakdown spectroscopy</title><title>Spectrochimica acta. Part B: Atomic spectroscopy</title><description>Hydrofluoric acid represents the majority of the industrial applications of fluorine in the world. It is synthetized from fluorite, which is commonly purified by the froth flotation process to attain the high-grades required for hydrofluoric acid production. Besides, in metallic ores such as tungsten and phosphate ores, fluorite does not represent any added value compared to the extracted metals and is, therefore, considered as a gangue mineral that has to be rejected. In both cases, the fluorine content has to be known precisely in the flotation process as well as in all the industrial applications involving fluorine, to estimate the process efficiency and to optimise the operations. Nevertheless, fluorine quantification is difficult using conventional techniques since it usually includes heavy sample preparation such as dissolution. Though, Laser-Induced Breakdown Spectroscopy (LIBS) provides a multi-element detection that has been successfully used to quantify fluorine using either elementary or CaF molecular bands. Here, rock samples exhibiting a wide range of fluorine contents (from 1.48% to 40.73%) were analysed, the fluorine being mainly comprised in fluorite. These samples corresponded to the products of different flotation tests conducted on the same tungsten-skarn ore. The experimental conditions were optimised to study the two CaF molecular bands, located between 529 and 543 nm, and between 590 and 606 nm, respectively. Systematically, the LIBS emission intensities of the two studied bands were evaluated using the peak areas, which were normalised, averaged over several ablated zones, and correlated with the fluorine content determined by the fluoride-ion sensitive electrode method. The particle size played a key role as significant differences in the LIBS intensities were exhibited between the 10–150 μm and the &lt;20 μm powders, with no discernible correlation between the size ranges and signal magnitude. Furthermore, the matrix effects strongly impacted the LIBS intensities, which displayed a non-linear relationship with the fluorine contents: this induced the development of non-linear univariate models that were calculated on 27 training samples and validated on nine testing samples (3:1 ratio). Although non-linear models fitted adequately the experimental data, a multivariate approach considering the two studied CaF bands was adopted to overcome the matrix effects. A formula with linear, quadratic, and interaction terms was generated from the multivariate regression, predicting fluorine contents with R2 = 0.94 and a mean average error of 2.18%F. The developed models demonstrated that a precise and accurate quantification of fluorine is possible using a calibrated handheld LIBS, providing an on-line estimation of the processes efficiency and a real-time adaptation. [Display omitted] •Samples with fluorine content from 1.48% to 40.73% were analysed with handheld LIBS.•Peak areas of two CaF molecular bands were correlated with real fluorine contents.•Reducing the particle size increased the LIBS intensities without any actual correlation.•A non-linear correlation was exhibited between CaF intensity areas and fluorine contents.•Quantification accuracy was improved using multivariate models.</description><subject>Ablation</subject><subject>Acid production</subject><subject>Adaptation</subject><subject>Analytical methods</subject><subject>Bands</subject><subject>CaF</subject><subject>Emission analysis</subject><subject>Flotation</subject><subject>Fluorides</subject><subject>Fluorine</subject><subject>Fluorite</subject><subject>Gangue</subject><subject>Heavy metals</subject><subject>Hydrofluoric acid</subject><subject>Industrial applications</subject><subject>Laser induced breakdown spectroscopy</subject><subject>Lasers</subject><subject>LIBS</subject><subject>Mathematical analysis</subject><subject>Matrix methods</subject><subject>Metals</subject><subject>Minerals</subject><subject>Molecular bands</subject><subject>Multivariate analysis</subject><subject>Multivariate modelling</subject><subject>Non-linear models</subject><subject>Normalisation with total light</subject><subject>Optimization</subject><subject>Ores</subject><subject>Particle size</subject><subject>Phosphates</subject><subject>Physics</subject><subject>Regression analysis</subject><subject>Sample preparation</subject><subject>Sediment samples</subject><subject>Spectroscopy</subject><subject>Spectrum analysis</subject><subject>Training</subject><subject>Tungsten</subject><issn>0584-8547</issn><issn>1873-3565</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kE9r3DAUxEVpodukH6A3QU892JEsyZLpKYSmKSzkkrt41p-uNo7kSHJKvn21bGlvPT0YZoY3P4Q-UdJTQserY19g7gdCp56InlD5Bu2okqxjYhRv0Y4IxTsluHyPPpRyJIQMYhA79Hi_1vAUCtSQIk4eeygVP28Qa_DB_JOXLeUQHTYpVhcr3kqIP_EBoj24xeIFiss4RLsZZ_GcHTza9CvisjpTcyomra-X6J2HpbiPf-4Ferj99nBz1-3vv_-4ud53hpOhdo4xAsrP0ilvYZ6YBzERJ0YCMzNqhAnaYXKkknvlGBUEBmusnaW3hrML9OVce4BFrzk8QX7VCYK-u97rk0YYV5wr9UKb9_PZu-b0vLlS9TFtObbv9MDIyOUo2dRc9OwybUnJzv-tpUSf8Oujbvj1Cb8mQjf8LfP1nHFt6UtwWRcTXGx0Qm5ItE3hP-nfpJePqw</recordid><startdate>20190801</startdate><enddate>20190801</enddate><creator>Foucaud, Y.</creator><creator>Fabre, C.</creator><creator>Demeusy, B.</creator><creator>Filippova, I.V.</creator><creator>Filippov, L.O.</creator><general>Elsevier B.V</general><general>Elsevier BV</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7SR</scope><scope>7U5</scope><scope>7UA</scope><scope>8FD</scope><scope>C1K</scope><scope>F1W</scope><scope>H97</scope><scope>JG9</scope><scope>L.G</scope><scope>L7M</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0001-8627-4050</orcidid><orcidid>https://orcid.org/0000-0002-8846-4218</orcidid></search><sort><creationdate>20190801</creationdate><title>Optimisation of fast quantification of fluorine content using handheld laser induced breakdown spectroscopy</title><author>Foucaud, Y. ; Fabre, C. ; Demeusy, B. ; Filippova, I.V. ; Filippov, L.O.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c402t-e330a8fb7e8fdab93fa590e560ab3c86a9a3c8376174f8e3150a2dcddb7fdc43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Ablation</topic><topic>Acid production</topic><topic>Adaptation</topic><topic>Analytical methods</topic><topic>Bands</topic><topic>CaF</topic><topic>Emission analysis</topic><topic>Flotation</topic><topic>Fluorides</topic><topic>Fluorine</topic><topic>Fluorite</topic><topic>Gangue</topic><topic>Heavy metals</topic><topic>Hydrofluoric acid</topic><topic>Industrial applications</topic><topic>Laser induced breakdown spectroscopy</topic><topic>Lasers</topic><topic>LIBS</topic><topic>Mathematical analysis</topic><topic>Matrix methods</topic><topic>Metals</topic><topic>Minerals</topic><topic>Molecular bands</topic><topic>Multivariate analysis</topic><topic>Multivariate modelling</topic><topic>Non-linear models</topic><topic>Normalisation with total light</topic><topic>Optimization</topic><topic>Ores</topic><topic>Particle size</topic><topic>Phosphates</topic><topic>Physics</topic><topic>Regression analysis</topic><topic>Sample preparation</topic><topic>Sediment samples</topic><topic>Spectroscopy</topic><topic>Spectrum analysis</topic><topic>Training</topic><topic>Tungsten</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Foucaud, Y.</creatorcontrib><creatorcontrib>Fabre, C.</creatorcontrib><creatorcontrib>Demeusy, B.</creatorcontrib><creatorcontrib>Filippova, I.V.</creatorcontrib><creatorcontrib>Filippov, L.O.</creatorcontrib><collection>CrossRef</collection><collection>Aqualine</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>Materials Research Database</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Spectrochimica acta. Part B: Atomic spectroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Foucaud, Y.</au><au>Fabre, C.</au><au>Demeusy, B.</au><au>Filippova, I.V.</au><au>Filippov, L.O.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimisation of fast quantification of fluorine content using handheld laser induced breakdown spectroscopy</atitle><jtitle>Spectrochimica acta. Part B: Atomic spectroscopy</jtitle><date>2019-08-01</date><risdate>2019</risdate><volume>158</volume><spage>105628</spage><pages>105628-</pages><artnum>105628</artnum><issn>0584-8547</issn><eissn>1873-3565</eissn><abstract>Hydrofluoric acid represents the majority of the industrial applications of fluorine in the world. It is synthetized from fluorite, which is commonly purified by the froth flotation process to attain the high-grades required for hydrofluoric acid production. Besides, in metallic ores such as tungsten and phosphate ores, fluorite does not represent any added value compared to the extracted metals and is, therefore, considered as a gangue mineral that has to be rejected. In both cases, the fluorine content has to be known precisely in the flotation process as well as in all the industrial applications involving fluorine, to estimate the process efficiency and to optimise the operations. Nevertheless, fluorine quantification is difficult using conventional techniques since it usually includes heavy sample preparation such as dissolution. Though, Laser-Induced Breakdown Spectroscopy (LIBS) provides a multi-element detection that has been successfully used to quantify fluorine using either elementary or CaF molecular bands. Here, rock samples exhibiting a wide range of fluorine contents (from 1.48% to 40.73%) were analysed, the fluorine being mainly comprised in fluorite. These samples corresponded to the products of different flotation tests conducted on the same tungsten-skarn ore. The experimental conditions were optimised to study the two CaF molecular bands, located between 529 and 543 nm, and between 590 and 606 nm, respectively. Systematically, the LIBS emission intensities of the two studied bands were evaluated using the peak areas, which were normalised, averaged over several ablated zones, and correlated with the fluorine content determined by the fluoride-ion sensitive electrode method. The particle size played a key role as significant differences in the LIBS intensities were exhibited between the 10–150 μm and the &lt;20 μm powders, with no discernible correlation between the size ranges and signal magnitude. Furthermore, the matrix effects strongly impacted the LIBS intensities, which displayed a non-linear relationship with the fluorine contents: this induced the development of non-linear univariate models that were calculated on 27 training samples and validated on nine testing samples (3:1 ratio). Although non-linear models fitted adequately the experimental data, a multivariate approach considering the two studied CaF bands was adopted to overcome the matrix effects. A formula with linear, quadratic, and interaction terms was generated from the multivariate regression, predicting fluorine contents with R2 = 0.94 and a mean average error of 2.18%F. The developed models demonstrated that a precise and accurate quantification of fluorine is possible using a calibrated handheld LIBS, providing an on-line estimation of the processes efficiency and a real-time adaptation. [Display omitted] •Samples with fluorine content from 1.48% to 40.73% were analysed with handheld LIBS.•Peak areas of two CaF molecular bands were correlated with real fluorine contents.•Reducing the particle size increased the LIBS intensities without any actual correlation.•A non-linear correlation was exhibited between CaF intensity areas and fluorine contents.•Quantification accuracy was improved using multivariate models.</abstract><cop>Oxford</cop><pub>Elsevier B.V</pub><doi>10.1016/j.sab.2019.05.017</doi><orcidid>https://orcid.org/0000-0001-8627-4050</orcidid><orcidid>https://orcid.org/0000-0002-8846-4218</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0584-8547
ispartof Spectrochimica acta. Part B: Atomic spectroscopy, 2019-08, Vol.158, p.105628, Article 105628
issn 0584-8547
1873-3565
language eng
recordid cdi_hal_primary_oai_HAL_hal_03484488v1
source Elsevier ScienceDirect Journals
subjects Ablation
Acid production
Adaptation
Analytical methods
Bands
CaF
Emission analysis
Flotation
Fluorides
Fluorine
Fluorite
Gangue
Heavy metals
Hydrofluoric acid
Industrial applications
Laser induced breakdown spectroscopy
Lasers
LIBS
Mathematical analysis
Matrix methods
Metals
Minerals
Molecular bands
Multivariate analysis
Multivariate modelling
Non-linear models
Normalisation with total light
Optimization
Ores
Particle size
Phosphates
Physics
Regression analysis
Sample preparation
Sediment samples
Spectroscopy
Spectrum analysis
Training
Tungsten
title Optimisation of fast quantification of fluorine content using handheld laser induced breakdown spectroscopy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T15%3A35%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimisation%20of%20fast%20quantification%20of%20fluorine%20content%20using%20handheld%20laser%20induced%20breakdown%20spectroscopy&rft.jtitle=Spectrochimica%20acta.%20Part%20B:%20Atomic%20spectroscopy&rft.au=Foucaud,%20Y.&rft.date=2019-08-01&rft.volume=158&rft.spage=105628&rft.pages=105628-&rft.artnum=105628&rft.issn=0584-8547&rft.eissn=1873-3565&rft_id=info:doi/10.1016/j.sab.2019.05.017&rft_dat=%3Cproquest_hal_p%3E2306476739%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2306476739&rft_id=info:pmid/&rft_els_id=S0584854719300527&rfr_iscdi=true