Dosimetric methodology for 131I therapy for benign thyroid diseases
Treatment with 131I is one of the standard treatments for benign thyroid disease. In most cases, the prescribed dose is specific for the same disease. Inspired by external radiotherapy, the emergence of personalized pre-therapeutic dosimetry in nuclear medicine departments makes it possible to adapt...
Gespeichert in:
Veröffentlicht in: | Médecine nucléaire : imagerie fonctionelle et métabolique 2020-10, Vol.44 (4), p.261-266 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 266 |
---|---|
container_issue | 4 |
container_start_page | 261 |
container_title | Médecine nucléaire : imagerie fonctionelle et métabolique |
container_volume | 44 |
creator | Piron, B. Broggio, D. Bardiès, M. Barrau, C. Kotzki, P.O. Boudousq, V. |
description | Treatment with 131I is one of the standard treatments for benign thyroid disease. In most cases, the prescribed dose is specific for the same disease. Inspired by external radiotherapy, the emergence of personalized pre-therapeutic dosimetry in nuclear medicine departments makes it possible to adapt to the patient's diseases and physiology; more specific to its kinetics of iodine distribution. By personalizing the prescribed activity, dosimetry makes it possible to comply with the ALARA principle in metabolic radiotherapy while at the same time preserving the therapeutic objective. Post-treatment dosimetry permits to validate the methodology and, by recording the dose actually delivered to the organs surrounding the target volume, to contribute to the understanding of the dose-effect relationship. A re-reading of the MIRD formalism guidelines is important as this document lists the procedure to be followed in thyroid dosimetry. Defining the sensitivity, calculating the S factors, estimating the cumulative activity and residence times and then calculating the dose are the different steps presented. The need to switch from fixed dose prescription to personalized prescription seems to be evident. Several studies in progress as well as the emergence of new software compiling all the information essential for its implementation will permit nuclear medicine departments to involve themselves more easily into the process.
Le traitement à l’iode 131 fait partie des traitements de référence pour les maladies bénignes de la thyroïde. Habituellement, la dose prescrite est unique pour une même maladie. Inspirée de la radiothérapie externe, l’émergence de la dosimétrie personnalisée pré-thérapeutique dans les services de médecine nucléaire permet de s’adapter à la maladie et à la physiologie du patient ; plus particulière à sa cinétique de distribution de l’iode. En personnalisant l’activité prescrite, la dosimétrie permet de se conformer au principe ALARA en radiothérapie métabolique tout en préservant l’objectif thérapeutique. La dosimétrie post-traitement permet quant à elle de valider la méthodologie et, en relevant la dose réellement délivrée aux organes avoisinant le volume cible, de contribuer à la compréhension de la relation dose-effet. Après un rappel du formalisme du MIRD sur lequel s’appuie le calcul de dose, ce document recense la démarche à suivre en dosimétrie thyroïdienne. Définition de la sensibilité, calcul des facteurs S, estimation de l’activité cumu |
doi_str_mv | 10.1016/j.mednuc.2020.06.004 |
format | Article |
fullrecord | <record><control><sourceid>hal_cross</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_03192275v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0928125820302047</els_id><sourcerecordid>oai_HAL_hal_03192275v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1851-aaf4a11052aa67e253eb60bd7d3eb39e56302ab38cb0b021c061eef364f4d5c73</originalsourceid><addsrcrecordid>eNp9kEFLAzEQhYMoWKv_wMNePew6k-xm04tQqrWFghc9h2wy26a0m5LUQv-9W1Y8enrD470H8zH2iFAgoHzeFnty3bctOHAoQBYA5RUboapVLhWHazaCCVc58krdsruUtgBYI6oRm72G5Pd0jN5mvWyCC7uwPmdtiBkKXGbHDUVzGIyGOr_ueuscg3eZ84lMonTPblqzS_Twq2P2NX_7nC3y1cf7cjZd5RZVhbkxbWkQoeLGyJp4JaiR0Lja9YeYUCUFcNMIZRtogKMFiUStkGVbusrWYsyeht2N2elD9HsTzzoYrxfTlb54IHDCeV2dsM-WQ9bGkFKk9q-AoC_Q9FYP0PQFmgape2h97WWoUf_HyVPUyXrqLDkfyR61C_7_gR-LX3aG</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Dosimetric methodology for 131I therapy for benign thyroid diseases</title><source>Access via ScienceDirect (Elsevier)</source><creator>Piron, B. ; Broggio, D. ; Bardiès, M. ; Barrau, C. ; Kotzki, P.O. ; Boudousq, V.</creator><creatorcontrib>Piron, B. ; Broggio, D. ; Bardiès, M. ; Barrau, C. ; Kotzki, P.O. ; Boudousq, V.</creatorcontrib><description>Treatment with 131I is one of the standard treatments for benign thyroid disease. In most cases, the prescribed dose is specific for the same disease. Inspired by external radiotherapy, the emergence of personalized pre-therapeutic dosimetry in nuclear medicine departments makes it possible to adapt to the patient's diseases and physiology; more specific to its kinetics of iodine distribution. By personalizing the prescribed activity, dosimetry makes it possible to comply with the ALARA principle in metabolic radiotherapy while at the same time preserving the therapeutic objective. Post-treatment dosimetry permits to validate the methodology and, by recording the dose actually delivered to the organs surrounding the target volume, to contribute to the understanding of the dose-effect relationship. A re-reading of the MIRD formalism guidelines is important as this document lists the procedure to be followed in thyroid dosimetry. Defining the sensitivity, calculating the S factors, estimating the cumulative activity and residence times and then calculating the dose are the different steps presented. The need to switch from fixed dose prescription to personalized prescription seems to be evident. Several studies in progress as well as the emergence of new software compiling all the information essential for its implementation will permit nuclear medicine departments to involve themselves more easily into the process.
Le traitement à l’iode 131 fait partie des traitements de référence pour les maladies bénignes de la thyroïde. Habituellement, la dose prescrite est unique pour une même maladie. Inspirée de la radiothérapie externe, l’émergence de la dosimétrie personnalisée pré-thérapeutique dans les services de médecine nucléaire permet de s’adapter à la maladie et à la physiologie du patient ; plus particulière à sa cinétique de distribution de l’iode. En personnalisant l’activité prescrite, la dosimétrie permet de se conformer au principe ALARA en radiothérapie métabolique tout en préservant l’objectif thérapeutique. La dosimétrie post-traitement permet quant à elle de valider la méthodologie et, en relevant la dose réellement délivrée aux organes avoisinant le volume cible, de contribuer à la compréhension de la relation dose-effet. Après un rappel du formalisme du MIRD sur lequel s’appuie le calcul de dose, ce document recense la démarche à suivre en dosimétrie thyroïdienne. Définition de la sensibilité, calcul des facteurs S, estimation de l’activité cumulée et des temps de résidence puis calcul de la dose sont les différentes étapes présentées. La nécessité d’une bascule de la prescription en dose fixe à la prescription personnalisée semble aujourd’hui être une évidence. De nombreuses études en cours ainsi que l’émergence de nouveaux logiciels compilant l’ensemble des informations indispensables pour sa mise en œuvre permettent aux services de médecine nucléaire de se projeter plus facilement dans la démarche.</description><identifier>ISSN: 0928-1258</identifier><identifier>EISSN: 1878-6820</identifier><identifier>DOI: 10.1016/j.mednuc.2020.06.004</identifier><language>eng</language><publisher>Elsevier Masson SAS</publisher><subject>Benign thyroid disease ; Dosimétrie personnalisée ; Life Sciences ; Maladie bénigne de la thyroïde ; Personalized dosimetry ; Radiodine therapy ; Traitement à l’iode 131</subject><ispartof>Médecine nucléaire : imagerie fonctionelle et métabolique, 2020-10, Vol.44 (4), p.261-266</ispartof><rights>2020 Elsevier Masson SAS</rights><rights>Attribution - NonCommercial</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1851-aaf4a11052aa67e253eb60bd7d3eb39e56302ab38cb0b021c061eef364f4d5c73</citedby><cites>FETCH-LOGICAL-c1851-aaf4a11052aa67e253eb60bd7d3eb39e56302ab38cb0b021c061eef364f4d5c73</cites><orcidid>0000-0001-8118-8268</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.mednuc.2020.06.004$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,315,782,786,887,3552,27931,27932,46002</link.rule.ids><backlink>$$Uhttps://hal.science/hal-03192275$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Piron, B.</creatorcontrib><creatorcontrib>Broggio, D.</creatorcontrib><creatorcontrib>Bardiès, M.</creatorcontrib><creatorcontrib>Barrau, C.</creatorcontrib><creatorcontrib>Kotzki, P.O.</creatorcontrib><creatorcontrib>Boudousq, V.</creatorcontrib><title>Dosimetric methodology for 131I therapy for benign thyroid diseases</title><title>Médecine nucléaire : imagerie fonctionelle et métabolique</title><description>Treatment with 131I is one of the standard treatments for benign thyroid disease. In most cases, the prescribed dose is specific for the same disease. Inspired by external radiotherapy, the emergence of personalized pre-therapeutic dosimetry in nuclear medicine departments makes it possible to adapt to the patient's diseases and physiology; more specific to its kinetics of iodine distribution. By personalizing the prescribed activity, dosimetry makes it possible to comply with the ALARA principle in metabolic radiotherapy while at the same time preserving the therapeutic objective. Post-treatment dosimetry permits to validate the methodology and, by recording the dose actually delivered to the organs surrounding the target volume, to contribute to the understanding of the dose-effect relationship. A re-reading of the MIRD formalism guidelines is important as this document lists the procedure to be followed in thyroid dosimetry. Defining the sensitivity, calculating the S factors, estimating the cumulative activity and residence times and then calculating the dose are the different steps presented. The need to switch from fixed dose prescription to personalized prescription seems to be evident. Several studies in progress as well as the emergence of new software compiling all the information essential for its implementation will permit nuclear medicine departments to involve themselves more easily into the process.
Le traitement à l’iode 131 fait partie des traitements de référence pour les maladies bénignes de la thyroïde. Habituellement, la dose prescrite est unique pour une même maladie. Inspirée de la radiothérapie externe, l’émergence de la dosimétrie personnalisée pré-thérapeutique dans les services de médecine nucléaire permet de s’adapter à la maladie et à la physiologie du patient ; plus particulière à sa cinétique de distribution de l’iode. En personnalisant l’activité prescrite, la dosimétrie permet de se conformer au principe ALARA en radiothérapie métabolique tout en préservant l’objectif thérapeutique. La dosimétrie post-traitement permet quant à elle de valider la méthodologie et, en relevant la dose réellement délivrée aux organes avoisinant le volume cible, de contribuer à la compréhension de la relation dose-effet. Après un rappel du formalisme du MIRD sur lequel s’appuie le calcul de dose, ce document recense la démarche à suivre en dosimétrie thyroïdienne. Définition de la sensibilité, calcul des facteurs S, estimation de l’activité cumulée et des temps de résidence puis calcul de la dose sont les différentes étapes présentées. La nécessité d’une bascule de la prescription en dose fixe à la prescription personnalisée semble aujourd’hui être une évidence. De nombreuses études en cours ainsi que l’émergence de nouveaux logiciels compilant l’ensemble des informations indispensables pour sa mise en œuvre permettent aux services de médecine nucléaire de se projeter plus facilement dans la démarche.</description><subject>Benign thyroid disease</subject><subject>Dosimétrie personnalisée</subject><subject>Life Sciences</subject><subject>Maladie bénigne de la thyroïde</subject><subject>Personalized dosimetry</subject><subject>Radiodine therapy</subject><subject>Traitement à l’iode 131</subject><issn>0928-1258</issn><issn>1878-6820</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kEFLAzEQhYMoWKv_wMNePew6k-xm04tQqrWFghc9h2wy26a0m5LUQv-9W1Y8enrD470H8zH2iFAgoHzeFnty3bctOHAoQBYA5RUboapVLhWHazaCCVc58krdsruUtgBYI6oRm72G5Pd0jN5mvWyCC7uwPmdtiBkKXGbHDUVzGIyGOr_ueuscg3eZ84lMonTPblqzS_Twq2P2NX_7nC3y1cf7cjZd5RZVhbkxbWkQoeLGyJp4JaiR0Lja9YeYUCUFcNMIZRtogKMFiUStkGVbusrWYsyeht2N2elD9HsTzzoYrxfTlb54IHDCeV2dsM-WQ9bGkFKk9q-AoC_Q9FYP0PQFmgape2h97WWoUf_HyVPUyXrqLDkfyR61C_7_gR-LX3aG</recordid><startdate>202010</startdate><enddate>202010</enddate><creator>Piron, B.</creator><creator>Broggio, D.</creator><creator>Bardiès, M.</creator><creator>Barrau, C.</creator><creator>Kotzki, P.O.</creator><creator>Boudousq, V.</creator><general>Elsevier Masson SAS</general><general>Elsevier/Masson</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0001-8118-8268</orcidid></search><sort><creationdate>202010</creationdate><title>Dosimetric methodology for 131I therapy for benign thyroid diseases</title><author>Piron, B. ; Broggio, D. ; Bardiès, M. ; Barrau, C. ; Kotzki, P.O. ; Boudousq, V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1851-aaf4a11052aa67e253eb60bd7d3eb39e56302ab38cb0b021c061eef364f4d5c73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Benign thyroid disease</topic><topic>Dosimétrie personnalisée</topic><topic>Life Sciences</topic><topic>Maladie bénigne de la thyroïde</topic><topic>Personalized dosimetry</topic><topic>Radiodine therapy</topic><topic>Traitement à l’iode 131</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Piron, B.</creatorcontrib><creatorcontrib>Broggio, D.</creatorcontrib><creatorcontrib>Bardiès, M.</creatorcontrib><creatorcontrib>Barrau, C.</creatorcontrib><creatorcontrib>Kotzki, P.O.</creatorcontrib><creatorcontrib>Boudousq, V.</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Médecine nucléaire : imagerie fonctionelle et métabolique</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Piron, B.</au><au>Broggio, D.</au><au>Bardiès, M.</au><au>Barrau, C.</au><au>Kotzki, P.O.</au><au>Boudousq, V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dosimetric methodology for 131I therapy for benign thyroid diseases</atitle><jtitle>Médecine nucléaire : imagerie fonctionelle et métabolique</jtitle><date>2020-10</date><risdate>2020</risdate><volume>44</volume><issue>4</issue><spage>261</spage><epage>266</epage><pages>261-266</pages><issn>0928-1258</issn><eissn>1878-6820</eissn><abstract>Treatment with 131I is one of the standard treatments for benign thyroid disease. In most cases, the prescribed dose is specific for the same disease. Inspired by external radiotherapy, the emergence of personalized pre-therapeutic dosimetry in nuclear medicine departments makes it possible to adapt to the patient's diseases and physiology; more specific to its kinetics of iodine distribution. By personalizing the prescribed activity, dosimetry makes it possible to comply with the ALARA principle in metabolic radiotherapy while at the same time preserving the therapeutic objective. Post-treatment dosimetry permits to validate the methodology and, by recording the dose actually delivered to the organs surrounding the target volume, to contribute to the understanding of the dose-effect relationship. A re-reading of the MIRD formalism guidelines is important as this document lists the procedure to be followed in thyroid dosimetry. Defining the sensitivity, calculating the S factors, estimating the cumulative activity and residence times and then calculating the dose are the different steps presented. The need to switch from fixed dose prescription to personalized prescription seems to be evident. Several studies in progress as well as the emergence of new software compiling all the information essential for its implementation will permit nuclear medicine departments to involve themselves more easily into the process.
Le traitement à l’iode 131 fait partie des traitements de référence pour les maladies bénignes de la thyroïde. Habituellement, la dose prescrite est unique pour une même maladie. Inspirée de la radiothérapie externe, l’émergence de la dosimétrie personnalisée pré-thérapeutique dans les services de médecine nucléaire permet de s’adapter à la maladie et à la physiologie du patient ; plus particulière à sa cinétique de distribution de l’iode. En personnalisant l’activité prescrite, la dosimétrie permet de se conformer au principe ALARA en radiothérapie métabolique tout en préservant l’objectif thérapeutique. La dosimétrie post-traitement permet quant à elle de valider la méthodologie et, en relevant la dose réellement délivrée aux organes avoisinant le volume cible, de contribuer à la compréhension de la relation dose-effet. Après un rappel du formalisme du MIRD sur lequel s’appuie le calcul de dose, ce document recense la démarche à suivre en dosimétrie thyroïdienne. Définition de la sensibilité, calcul des facteurs S, estimation de l’activité cumulée et des temps de résidence puis calcul de la dose sont les différentes étapes présentées. La nécessité d’une bascule de la prescription en dose fixe à la prescription personnalisée semble aujourd’hui être une évidence. De nombreuses études en cours ainsi que l’émergence de nouveaux logiciels compilant l’ensemble des informations indispensables pour sa mise en œuvre permettent aux services de médecine nucléaire de se projeter plus facilement dans la démarche.</abstract><pub>Elsevier Masson SAS</pub><doi>10.1016/j.mednuc.2020.06.004</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0001-8118-8268</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0928-1258 |
ispartof | Médecine nucléaire : imagerie fonctionelle et métabolique, 2020-10, Vol.44 (4), p.261-266 |
issn | 0928-1258 1878-6820 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_03192275v1 |
source | Access via ScienceDirect (Elsevier) |
subjects | Benign thyroid disease Dosimétrie personnalisée Life Sciences Maladie bénigne de la thyroïde Personalized dosimetry Radiodine therapy Traitement à l’iode 131 |
title | Dosimetric methodology for 131I therapy for benign thyroid diseases |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T16%3A12%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dosimetric%20methodology%20for%20131I%20therapy%20for%20benign%20thyroid%20diseases&rft.jtitle=M%C3%A9decine%20nucl%C3%A9aire%20:%20imagerie%20fonctionelle%20et%20m%C3%A9tabolique&rft.au=Piron,%20B.&rft.date=2020-10&rft.volume=44&rft.issue=4&rft.spage=261&rft.epage=266&rft.pages=261-266&rft.issn=0928-1258&rft.eissn=1878-6820&rft_id=info:doi/10.1016/j.mednuc.2020.06.004&rft_dat=%3Chal_cross%3Eoai_HAL_hal_03192275v1%3C/hal_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S0928125820302047&rfr_iscdi=true |