Sensor fault estimation of PEM fuel cells using Takagi Sugeno fuzzy model
This paper presents a sensor fault estimation scheme for polymer electrolyte membrane (PEM) fuel cells using Takagi Sugeno (TS) fuzzy model. First, PEM fuel cell systems with sensor faults are modelled by TS fuzzy model. Next, by adding a first order filter, an augmented TS fuzzy system with actuato...
Gespeichert in:
Veröffentlicht in: | International journal of hydrogen energy 2020-04, Vol.45 (19), p.11267-11275 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 11275 |
---|---|
container_issue | 19 |
container_start_page | 11267 |
container_title | International journal of hydrogen energy |
container_volume | 45 |
creator | Li, Shanzhi Aitouche, Abdel Wang, Haoping Christov, Nicolai |
description | This paper presents a sensor fault estimation scheme for polymer electrolyte membrane (PEM) fuel cells using Takagi Sugeno (TS) fuzzy model. First, PEM fuel cell systems with sensor faults are modelled by TS fuzzy model. Next, by adding a first order filter, an augmented TS fuzzy system with actuator fault is obtained. Then, for the augmented system, an unknown input observer (UIO) and a fault estimator are developed. The UIO gains are computed by solving linear matrix equalities (LMEs) and linear matrix inequalities (LMIs). The UIO convergence and stability are analyzed and the performances of the proposed fault estimation scheme is demonstrated by numerical simulations for a PEM fuel cell system with return manifold pressure and hydrogen mass sensors.
•A TS fuzzy model for PEM fuel cells is used to considering the system uncertainty.•The sensor fault is transferred into the actuator fault by a low-order filter.•For augmented system, an unknown input observer and fault estimator are derived.•The UIO gains are computed by solving LMEs and LMIs. |
doi_str_mv | 10.1016/j.ijhydene.2019.01.100 |
format | Article |
fullrecord | <record><control><sourceid>hal_cross</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_03113187v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0360319919302320</els_id><sourcerecordid>oai_HAL_hal_03113187v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-c346t-d2322fe96d7e5417815e17c56d076555162b877aba6ccdb3750b2e832d4c0f473</originalsourceid><addsrcrecordid>eNqFUMFOwkAU3BhNRPQXzF49FN_rtrvtTUJQSDCagOfNsvsKi6U13UICX28J6tXTS-bNTGaGsXuEAQLKx83Ab9YHRxUNYsB8ANjhcMF6mKk8EkmmLlkPhIRIYJ5fs5sQNgCoIMl7bDqnKtQNL8yubDmF1m9N6-uK1wV_H7_yYkclt1SWge-Cr1Z8YT7NyvP5bkVV3b2PxwPf1o7KW3ZVmDLQ3c_ts4_n8WI0iWZvL9PRcBZZkcg2crGI44Jy6RSlCaoMU0JlU-lAyTRNUcbLTCmzNNJatxQqhWVMmYhdYqFIlOizh7Pv2pT6q-nyNgddG68nw5k-YSAQRdd9jx1Xnrm2qUNoqPgTIOjTeHqjf8fTp_E0YIdDJ3w6C6lrsvfU6GA9VZacb8i22tX-P4tvXJ56XQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Sensor fault estimation of PEM fuel cells using Takagi Sugeno fuzzy model</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Li, Shanzhi ; Aitouche, Abdel ; Wang, Haoping ; Christov, Nicolai</creator><creatorcontrib>Li, Shanzhi ; Aitouche, Abdel ; Wang, Haoping ; Christov, Nicolai</creatorcontrib><description>This paper presents a sensor fault estimation scheme for polymer electrolyte membrane (PEM) fuel cells using Takagi Sugeno (TS) fuzzy model. First, PEM fuel cell systems with sensor faults are modelled by TS fuzzy model. Next, by adding a first order filter, an augmented TS fuzzy system with actuator fault is obtained. Then, for the augmented system, an unknown input observer (UIO) and a fault estimator are developed. The UIO gains are computed by solving linear matrix equalities (LMEs) and linear matrix inequalities (LMIs). The UIO convergence and stability are analyzed and the performances of the proposed fault estimation scheme is demonstrated by numerical simulations for a PEM fuel cell system with return manifold pressure and hydrogen mass sensors.
•A TS fuzzy model for PEM fuel cells is used to considering the system uncertainty.•The sensor fault is transferred into the actuator fault by a low-order filter.•For augmented system, an unknown input observer and fault estimator are derived.•The UIO gains are computed by solving LMEs and LMIs.</description><identifier>ISSN: 0360-3199</identifier><identifier>EISSN: 1879-3487</identifier><identifier>DOI: 10.1016/j.ijhydene.2019.01.100</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Engineering Sciences ; Fault estimation ; Fuel cells ; TS fuzzy system ; Unknown input observer</subject><ispartof>International journal of hydrogen energy, 2020-04, Vol.45 (19), p.11267-11275</ispartof><rights>2019 Hydrogen Energy Publications LLC</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c346t-d2322fe96d7e5417815e17c56d076555162b877aba6ccdb3750b2e832d4c0f473</citedby><cites>FETCH-LOGICAL-c346t-d2322fe96d7e5417815e17c56d076555162b877aba6ccdb3750b2e832d4c0f473</cites><orcidid>0000-0003-1888-1849 ; 0000-0001-9799-9647 ; 0000-0001-8910-7274</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ijhydene.2019.01.100$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://hal.science/hal-03113187$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Li, Shanzhi</creatorcontrib><creatorcontrib>Aitouche, Abdel</creatorcontrib><creatorcontrib>Wang, Haoping</creatorcontrib><creatorcontrib>Christov, Nicolai</creatorcontrib><title>Sensor fault estimation of PEM fuel cells using Takagi Sugeno fuzzy model</title><title>International journal of hydrogen energy</title><description>This paper presents a sensor fault estimation scheme for polymer electrolyte membrane (PEM) fuel cells using Takagi Sugeno (TS) fuzzy model. First, PEM fuel cell systems with sensor faults are modelled by TS fuzzy model. Next, by adding a first order filter, an augmented TS fuzzy system with actuator fault is obtained. Then, for the augmented system, an unknown input observer (UIO) and a fault estimator are developed. The UIO gains are computed by solving linear matrix equalities (LMEs) and linear matrix inequalities (LMIs). The UIO convergence and stability are analyzed and the performances of the proposed fault estimation scheme is demonstrated by numerical simulations for a PEM fuel cell system with return manifold pressure and hydrogen mass sensors.
•A TS fuzzy model for PEM fuel cells is used to considering the system uncertainty.•The sensor fault is transferred into the actuator fault by a low-order filter.•For augmented system, an unknown input observer and fault estimator are derived.•The UIO gains are computed by solving LMEs and LMIs.</description><subject>Engineering Sciences</subject><subject>Fault estimation</subject><subject>Fuel cells</subject><subject>TS fuzzy system</subject><subject>Unknown input observer</subject><issn>0360-3199</issn><issn>1879-3487</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFUMFOwkAU3BhNRPQXzF49FN_rtrvtTUJQSDCagOfNsvsKi6U13UICX28J6tXTS-bNTGaGsXuEAQLKx83Ab9YHRxUNYsB8ANjhcMF6mKk8EkmmLlkPhIRIYJ5fs5sQNgCoIMl7bDqnKtQNL8yubDmF1m9N6-uK1wV_H7_yYkclt1SWge-Cr1Z8YT7NyvP5bkVV3b2PxwPf1o7KW3ZVmDLQ3c_ts4_n8WI0iWZvL9PRcBZZkcg2crGI44Jy6RSlCaoMU0JlU-lAyTRNUcbLTCmzNNJatxQqhWVMmYhdYqFIlOizh7Pv2pT6q-nyNgddG68nw5k-YSAQRdd9jx1Xnrm2qUNoqPgTIOjTeHqjf8fTp_E0YIdDJ3w6C6lrsvfU6GA9VZacb8i22tX-P4tvXJ56XQ</recordid><startdate>20200403</startdate><enddate>20200403</enddate><creator>Li, Shanzhi</creator><creator>Aitouche, Abdel</creator><creator>Wang, Haoping</creator><creator>Christov, Nicolai</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><orcidid>https://orcid.org/0000-0003-1888-1849</orcidid><orcidid>https://orcid.org/0000-0001-9799-9647</orcidid><orcidid>https://orcid.org/0000-0001-8910-7274</orcidid></search><sort><creationdate>20200403</creationdate><title>Sensor fault estimation of PEM fuel cells using Takagi Sugeno fuzzy model</title><author>Li, Shanzhi ; Aitouche, Abdel ; Wang, Haoping ; Christov, Nicolai</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c346t-d2322fe96d7e5417815e17c56d076555162b877aba6ccdb3750b2e832d4c0f473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Engineering Sciences</topic><topic>Fault estimation</topic><topic>Fuel cells</topic><topic>TS fuzzy system</topic><topic>Unknown input observer</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Shanzhi</creatorcontrib><creatorcontrib>Aitouche, Abdel</creatorcontrib><creatorcontrib>Wang, Haoping</creatorcontrib><creatorcontrib>Christov, Nicolai</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>International journal of hydrogen energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Shanzhi</au><au>Aitouche, Abdel</au><au>Wang, Haoping</au><au>Christov, Nicolai</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensor fault estimation of PEM fuel cells using Takagi Sugeno fuzzy model</atitle><jtitle>International journal of hydrogen energy</jtitle><date>2020-04-03</date><risdate>2020</risdate><volume>45</volume><issue>19</issue><spage>11267</spage><epage>11275</epage><pages>11267-11275</pages><issn>0360-3199</issn><eissn>1879-3487</eissn><abstract>This paper presents a sensor fault estimation scheme for polymer electrolyte membrane (PEM) fuel cells using Takagi Sugeno (TS) fuzzy model. First, PEM fuel cell systems with sensor faults are modelled by TS fuzzy model. Next, by adding a first order filter, an augmented TS fuzzy system with actuator fault is obtained. Then, for the augmented system, an unknown input observer (UIO) and a fault estimator are developed. The UIO gains are computed by solving linear matrix equalities (LMEs) and linear matrix inequalities (LMIs). The UIO convergence and stability are analyzed and the performances of the proposed fault estimation scheme is demonstrated by numerical simulations for a PEM fuel cell system with return manifold pressure and hydrogen mass sensors.
•A TS fuzzy model for PEM fuel cells is used to considering the system uncertainty.•The sensor fault is transferred into the actuator fault by a low-order filter.•For augmented system, an unknown input observer and fault estimator are derived.•The UIO gains are computed by solving LMEs and LMIs.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.ijhydene.2019.01.100</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0003-1888-1849</orcidid><orcidid>https://orcid.org/0000-0001-9799-9647</orcidid><orcidid>https://orcid.org/0000-0001-8910-7274</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0360-3199 |
ispartof | International journal of hydrogen energy, 2020-04, Vol.45 (19), p.11267-11275 |
issn | 0360-3199 1879-3487 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_03113187v1 |
source | ScienceDirect Journals (5 years ago - present) |
subjects | Engineering Sciences Fault estimation Fuel cells TS fuzzy system Unknown input observer |
title | Sensor fault estimation of PEM fuel cells using Takagi Sugeno fuzzy model |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T23%3A34%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensor%20fault%20estimation%20of%20PEM%20fuel%20cells%20using%20Takagi%20Sugeno%20fuzzy%20model&rft.jtitle=International%20journal%20of%20hydrogen%20energy&rft.au=Li,%20Shanzhi&rft.date=2020-04-03&rft.volume=45&rft.issue=19&rft.spage=11267&rft.epage=11275&rft.pages=11267-11275&rft.issn=0360-3199&rft.eissn=1879-3487&rft_id=info:doi/10.1016/j.ijhydene.2019.01.100&rft_dat=%3Chal_cross%3Eoai_HAL_hal_03113187v1%3C/hal_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S0360319919302320&rfr_iscdi=true |