Methods and limitations of ‘clumped’ CO 2 isotope (Δ 47 ) analysis by gas‐source isotope ratio mass spectrometry

The geochemistry of multiply substituted isotopologues (‘clumped‐isotope’ geochemistry) examines the abundances in natural materials of molecules, formula units or moieties that contain more than one rare isotope (e.g. 13 C 18 O 16 O, 18 O 18 O, 15 N 2 , 13 C 18 O 16 O 2 2− ). Such species form the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of mass spectrometry. 2009-09, Vol.44 (9), p.1318-1329
Hauptverfasser: Huntington, K. W., Eiler, J. M., Affek, H. P., Guo, W., Bonifacie, M., Yeung, L. Y., Thiagarajan, N., Passey, B., Tripati, A., Daëron, M., Came, R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The geochemistry of multiply substituted isotopologues (‘clumped‐isotope’ geochemistry) examines the abundances in natural materials of molecules, formula units or moieties that contain more than one rare isotope (e.g. 13 C 18 O 16 O, 18 O 18 O, 15 N 2 , 13 C 18 O 16 O 2 2− ). Such species form the basis of carbonate clumped‐isotope thermometry and undergo distinctive fractionations during a variety of natural processes, but initial reports have provided few details of their analysis. In this study, we present detailed data and arguments regarding the theoretical and practical limits of precision, methods of standardization, instrument linearity and related issues for clumped‐isotope analysis by dual‐inlet gas‐source isotope ratio mass spectrometry (IRMS). We demonstrate long‐term stability and subtenth per mil precision in 47/44 ratios for counting systems consisting of a Faraday cup registered through a 10 12 Ω resistor on three Thermo‐Finnigan 253 IRMS systems. Based on the analyses of heated CO 2 gases, which have a stochastic distribution of isotopes among possible isotopologues, we document and correct for (1) isotopic exchange among analyte CO 2 molecules and (2) subtle nonlinearity in the relationship between actual and measured 47/44 ratios. External precisions of ∼0.01‰ are routinely achieved for measurements of the mass‐47 anomaly (a measure mostly of the abundance anomaly of 13 C‐ 18 O bonds) and follow counting statistics. The present technical limit to precision intrinsic to our methods and instrumentation is ∼5 parts per million (ppm), whereas precisions of measurements of heterogeneous natural materials are more typically ∼10 ppm (both 1 s.e.). These correspond to errors in carbonate clumped‐isotope thermometry of ±1.2 °C and ±2.4 °C, respectively. Copyright © 2009 John Wiley & Sons, Ltd.
ISSN:1076-5174
1096-9888