Fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RGDfC): exploiting all the abilities of the AllInOne synthesizer

Radiolabelled peptides are crucial tools for biomedical research purposes. Peptides are usually labeled with fluorine-18 via an indirect prosthetic group approach, which requires a complex multistep procedure not easily automatable. However, automation is a compulsory step of paramount importance to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Reaction chemistry & engineering 2019-12, Vol.4 (12), p.2088-2098
Hauptverfasser: Collet, Charlotte, Vucko, Timothé, Ariztia, Julen, Karcher, Gilles, Pellegrini-Moïse, Nadia, Lamandé-Langle, Sandrine
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2098
container_issue 12
container_start_page 2088
container_title Reaction chemistry & engineering
container_volume 4
creator Collet, Charlotte
Vucko, Timothé
Ariztia, Julen
Karcher, Gilles
Pellegrini-Moïse, Nadia
Lamandé-Langle, Sandrine
description Radiolabelled peptides are crucial tools for biomedical research purposes. Peptides are usually labeled with fluorine-18 via an indirect prosthetic group approach, which requires a complex multistep procedure not easily automatable. However, automation is a compulsory step of paramount importance to produce radiotracers with high reliability and minimal human involvement. Herein, we describe the fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RDGfC) on an AllInOne (AIO) synthesizer, exploiting for the first time all the abilities of the AIO module. The radiotracer was prepared in high radiochemical purity via a challenging three-step sequence in 140 minutes with a decay-corrected radiochemical yield of 3.6 ± 0.4%. Presenting a high stability and an improved hydrophilicity, [ 18 F]fluoro- C -glyco-c(RDGfC) could become a valuable tool in PET imaging for cancer diagnosis. Furthermore, the described automated procedure is modular and could be adapted to other prosthetic groups and/or peptides with minimal changes to afford a large panel of 18 F-radiolabeled peptides.
doi_str_mv 10.1039/C9RE00303G
format Article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_02520555v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2315466962</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-60b9928d65aa834bdb8d857bfe92c755647e7e7ffc9be9ba710b31ed370eab7c3</originalsourceid><addsrcrecordid>eNpNkV1LwzAUhoMoOHQ3_oKAN06oJs3SJt6Nui8YDIZeiZSkTbaOrJlJK0788WbOL87FObw85-VwXgAuMLrBiPDbjC-GCBFExkegEyPKIs4YOf43n4Ku92uEEE4CyNIO-Bi1xuygaBu7EY0qoRNlZf2ublbKVx5aDZ8gZnD0rE1rnY1gBqOl2RU2Kq4W43ud9e6getsaWzVVvYTCGBhWoZCVCYr6ctgLA2Om9bxW8Mf7XblzcKKF8ar73c_A42j4kE2i2Xw8zQazqCAxb6IESc5jViZUCEb6spSsZDSVWvG4SClN-qkKpXXBpeJSpBhJglVJUqSETAtyBnoH35Uw-dZVG-F2uRVVPhnM8r2GYhp-ROkrDuzlgd06-9Iq3-Rr27o6nJfHBNN-kvAkDtT1gSqc9d4p_WuLUb4PI_8Lg3wCvuR7Cw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2315466962</pqid></control><display><type>article</type><title>Fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RGDfC): exploiting all the abilities of the AllInOne synthesizer</title><source>Royal Society Of Chemistry Journals 2008-</source><creator>Collet, Charlotte ; Vucko, Timothé ; Ariztia, Julen ; Karcher, Gilles ; Pellegrini-Moïse, Nadia ; Lamandé-Langle, Sandrine</creator><creatorcontrib>Collet, Charlotte ; Vucko, Timothé ; Ariztia, Julen ; Karcher, Gilles ; Pellegrini-Moïse, Nadia ; Lamandé-Langle, Sandrine</creatorcontrib><description>Radiolabelled peptides are crucial tools for biomedical research purposes. Peptides are usually labeled with fluorine-18 via an indirect prosthetic group approach, which requires a complex multistep procedure not easily automatable. However, automation is a compulsory step of paramount importance to produce radiotracers with high reliability and minimal human involvement. Herein, we describe the fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RDGfC) on an AllInOne (AIO) synthesizer, exploiting for the first time all the abilities of the AIO module. The radiotracer was prepared in high radiochemical purity via a challenging three-step sequence in 140 minutes with a decay-corrected radiochemical yield of 3.6 ± 0.4%. Presenting a high stability and an improved hydrophilicity, [ 18 F]fluoro- C -glyco-c(RDGfC) could become a valuable tool in PET imaging for cancer diagnosis. Furthermore, the described automated procedure is modular and could be adapted to other prosthetic groups and/or peptides with minimal changes to afford a large panel of 18 F-radiolabeled peptides.</description><identifier>ISSN: 2058-9883</identifier><identifier>EISSN: 2058-9883</identifier><identifier>DOI: 10.1039/C9RE00303G</identifier><language>eng</language><publisher>Cambridge: Royal Society of Chemistry</publisher><subject>Automation ; Chemical Sciences ; Fluorine ; Fluorine isotopes ; Peptides ; Positron emission ; Prostheses ; Radioactive tracers ; Radioactivity ; Radiochemistry ; Synthesis ; Tomography</subject><ispartof>Reaction chemistry &amp; engineering, 2019-12, Vol.4 (12), p.2088-2098</ispartof><rights>Copyright Royal Society of Chemistry 2019</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-60b9928d65aa834bdb8d857bfe92c755647e7e7ffc9be9ba710b31ed370eab7c3</citedby><cites>FETCH-LOGICAL-c329t-60b9928d65aa834bdb8d857bfe92c755647e7e7ffc9be9ba710b31ed370eab7c3</cites><orcidid>0000-0001-8569-5793 ; 0000-0001-5576-3011</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://hal.univ-lorraine.fr/hal-02520555$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Collet, Charlotte</creatorcontrib><creatorcontrib>Vucko, Timothé</creatorcontrib><creatorcontrib>Ariztia, Julen</creatorcontrib><creatorcontrib>Karcher, Gilles</creatorcontrib><creatorcontrib>Pellegrini-Moïse, Nadia</creatorcontrib><creatorcontrib>Lamandé-Langle, Sandrine</creatorcontrib><title>Fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RGDfC): exploiting all the abilities of the AllInOne synthesizer</title><title>Reaction chemistry &amp; engineering</title><description>Radiolabelled peptides are crucial tools for biomedical research purposes. Peptides are usually labeled with fluorine-18 via an indirect prosthetic group approach, which requires a complex multistep procedure not easily automatable. However, automation is a compulsory step of paramount importance to produce radiotracers with high reliability and minimal human involvement. Herein, we describe the fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RDGfC) on an AllInOne (AIO) synthesizer, exploiting for the first time all the abilities of the AIO module. The radiotracer was prepared in high radiochemical purity via a challenging three-step sequence in 140 minutes with a decay-corrected radiochemical yield of 3.6 ± 0.4%. Presenting a high stability and an improved hydrophilicity, [ 18 F]fluoro- C -glyco-c(RDGfC) could become a valuable tool in PET imaging for cancer diagnosis. Furthermore, the described automated procedure is modular and could be adapted to other prosthetic groups and/or peptides with minimal changes to afford a large panel of 18 F-radiolabeled peptides.</description><subject>Automation</subject><subject>Chemical Sciences</subject><subject>Fluorine</subject><subject>Fluorine isotopes</subject><subject>Peptides</subject><subject>Positron emission</subject><subject>Prostheses</subject><subject>Radioactive tracers</subject><subject>Radioactivity</subject><subject>Radiochemistry</subject><subject>Synthesis</subject><subject>Tomography</subject><issn>2058-9883</issn><issn>2058-9883</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpNkV1LwzAUhoMoOHQ3_oKAN06oJs3SJt6Nui8YDIZeiZSkTbaOrJlJK0788WbOL87FObw85-VwXgAuMLrBiPDbjC-GCBFExkegEyPKIs4YOf43n4Ku92uEEE4CyNIO-Bi1xuygaBu7EY0qoRNlZf2ublbKVx5aDZ8gZnD0rE1rnY1gBqOl2RU2Kq4W43ud9e6getsaWzVVvYTCGBhWoZCVCYr6ctgLA2Om9bxW8Mf7XblzcKKF8ar73c_A42j4kE2i2Xw8zQazqCAxb6IESc5jViZUCEb6spSsZDSVWvG4SClN-qkKpXXBpeJSpBhJglVJUqSETAtyBnoH35Uw-dZVG-F2uRVVPhnM8r2GYhp-ROkrDuzlgd06-9Iq3-Rr27o6nJfHBNN-kvAkDtT1gSqc9d4p_WuLUb4PI_8Lg3wCvuR7Cw</recordid><startdate>20191201</startdate><enddate>20191201</enddate><creator>Collet, Charlotte</creator><creator>Vucko, Timothé</creator><creator>Ariztia, Julen</creator><creator>Karcher, Gilles</creator><creator>Pellegrini-Moïse, Nadia</creator><creator>Lamandé-Langle, Sandrine</creator><general>Royal Society of Chemistry</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0001-8569-5793</orcidid><orcidid>https://orcid.org/0000-0001-5576-3011</orcidid></search><sort><creationdate>20191201</creationdate><title>Fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RGDfC): exploiting all the abilities of the AllInOne synthesizer</title><author>Collet, Charlotte ; Vucko, Timothé ; Ariztia, Julen ; Karcher, Gilles ; Pellegrini-Moïse, Nadia ; Lamandé-Langle, Sandrine</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-60b9928d65aa834bdb8d857bfe92c755647e7e7ffc9be9ba710b31ed370eab7c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Automation</topic><topic>Chemical Sciences</topic><topic>Fluorine</topic><topic>Fluorine isotopes</topic><topic>Peptides</topic><topic>Positron emission</topic><topic>Prostheses</topic><topic>Radioactive tracers</topic><topic>Radioactivity</topic><topic>Radiochemistry</topic><topic>Synthesis</topic><topic>Tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Collet, Charlotte</creatorcontrib><creatorcontrib>Vucko, Timothé</creatorcontrib><creatorcontrib>Ariztia, Julen</creatorcontrib><creatorcontrib>Karcher, Gilles</creatorcontrib><creatorcontrib>Pellegrini-Moïse, Nadia</creatorcontrib><creatorcontrib>Lamandé-Langle, Sandrine</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Reaction chemistry &amp; engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Collet, Charlotte</au><au>Vucko, Timothé</au><au>Ariztia, Julen</au><au>Karcher, Gilles</au><au>Pellegrini-Moïse, Nadia</au><au>Lamandé-Langle, Sandrine</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RGDfC): exploiting all the abilities of the AllInOne synthesizer</atitle><jtitle>Reaction chemistry &amp; engineering</jtitle><date>2019-12-01</date><risdate>2019</risdate><volume>4</volume><issue>12</issue><spage>2088</spage><epage>2098</epage><pages>2088-2098</pages><issn>2058-9883</issn><eissn>2058-9883</eissn><abstract>Radiolabelled peptides are crucial tools for biomedical research purposes. Peptides are usually labeled with fluorine-18 via an indirect prosthetic group approach, which requires a complex multistep procedure not easily automatable. However, automation is a compulsory step of paramount importance to produce radiotracers with high reliability and minimal human involvement. Herein, we describe the fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RDGfC) on an AllInOne (AIO) synthesizer, exploiting for the first time all the abilities of the AIO module. The radiotracer was prepared in high radiochemical purity via a challenging three-step sequence in 140 minutes with a decay-corrected radiochemical yield of 3.6 ± 0.4%. Presenting a high stability and an improved hydrophilicity, [ 18 F]fluoro- C -glyco-c(RDGfC) could become a valuable tool in PET imaging for cancer diagnosis. Furthermore, the described automated procedure is modular and could be adapted to other prosthetic groups and/or peptides with minimal changes to afford a large panel of 18 F-radiolabeled peptides.</abstract><cop>Cambridge</cop><pub>Royal Society of Chemistry</pub><doi>10.1039/C9RE00303G</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-8569-5793</orcidid><orcidid>https://orcid.org/0000-0001-5576-3011</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2058-9883
ispartof Reaction chemistry & engineering, 2019-12, Vol.4 (12), p.2088-2098
issn 2058-9883
2058-9883
language eng
recordid cdi_hal_primary_oai_HAL_hal_02520555v1
source Royal Society Of Chemistry Journals 2008-
subjects Automation
Chemical Sciences
Fluorine
Fluorine isotopes
Peptides
Positron emission
Prostheses
Radioactive tracers
Radioactivity
Radiochemistry
Synthesis
Tomography
title Fully automated radiosynthesis of [ 18 F]fluoro- C -glyco-c(RGDfC): exploiting all the abilities of the AllInOne synthesizer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T17%3A47%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fully%20automated%20radiosynthesis%20of%20%5B%2018%20F%5Dfluoro-%20C%20-glyco-c(RGDfC):%20exploiting%20all%20the%20abilities%20of%20the%20AllInOne%20synthesizer&rft.jtitle=Reaction%20chemistry%20&%20engineering&rft.au=Collet,%20Charlotte&rft.date=2019-12-01&rft.volume=4&rft.issue=12&rft.spage=2088&rft.epage=2098&rft.pages=2088-2098&rft.issn=2058-9883&rft.eissn=2058-9883&rft_id=info:doi/10.1039/C9RE00303G&rft_dat=%3Cproquest_hal_p%3E2315466962%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2315466962&rft_id=info:pmid/&rfr_iscdi=true