Thermodynamic analysis of a 200 MWh electricity storage system based on high temperature thermal energy storage

With the increase in the share of intermittent renewable energies as part of the global energy mix comes the issue of energy storage. This work concerns a power-to-power electricity storage relying on sensible storage at high temperature (900 °C). A focus is put on finding the best compromise betwee...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy (Oxford) 2019-04, Vol.172, p.1132-1143
Hauptverfasser: Attonaty, Kevin, Stouffs, Pascal, Pouvreau, Jérôme, Oriol, Jean, Deydier, Alexandre
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1143
container_issue
container_start_page 1132
container_title Energy (Oxford)
container_volume 172
creator Attonaty, Kevin
Stouffs, Pascal
Pouvreau, Jérôme
Oriol, Jean
Deydier, Alexandre
description With the increase in the share of intermittent renewable energies as part of the global energy mix comes the issue of energy storage. This work concerns a power-to-power electricity storage relying on sensible storage at high temperature (900 °C). A focus is put on finding the best compromise between the valorization of the stored energy and the optimal functioning of the power-to-power process. The charging loop is made of an electrical heater and fans, while the conversion of the stored heat to electricity can be done in a gas cycle or a combined cycle. To set up a relevant base design for the system, the reciprocal influence of the storage and the discharging cycle needs to be evaluated. A thermodynamic modeling was therefore carried on and first and second law (or exergy) analyses were performed. Results show that the choice of the discharging cycle has a high impact on the sizing of the storage, by inducing different levels of pressure or temperature. Adding combustion in the discharging phase allows to achieve a better power-to-power efficiency and to reduce the storage volume, but also involves a fuel consumption that is not negligible. Finally, the power-to-heat conversion leads to high exergy destructions in the charging loop but thanks to the high temperature of the storage, this exergy destruction is not excessive when compared to conventional heat input from combustion systems. •The round-trip efficiency reaches around 50% in a combined cycle with combustion.•The electricity to heat conversion at 900 °C destroys about 30% of the inlet exergy.•Three possible architectures of the system have been studied.•Energy release in a gas cycle was found to be poorly efficient.•Packed bed thermal storage represents less than 10% of the global exergy destruction.
doi_str_mv 10.1016/j.energy.2019.01.153
format Article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_02153245v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0360544219301690</els_id><sourcerecordid>2216893080</sourcerecordid><originalsourceid>FETCH-LOGICAL-c414t-5c1320ee1b6f78d5d21c41b15c33ec4ae79246e4b85266741e9169d345d002543</originalsourceid><addsrcrecordid>eNp9UctuFDEQtBBILIE_4GCJE4cZuv2YxwUpiiBBWsQlUY6W19O749XseGPPRppb_oh_4kvi1RCOnFrqrqruqmbsI0KJgNWXfUkjxd1cCsC2BCxRy1dshU0ti6pu9Gu2AllBoZUSb9m7lPYAoJu2XbGH257iIXTzaA_ecTvaYU4-8bDllguAP0-_f973nAZyU_TOTzNPU4h2RzzNaaID39hEHQ8j7_2u57lzpGinUyQ-naXtwJfjXnjv2ZutHRJ9-Fsv2N33b7dXN8X61_WPq8t14RSqqdAOpQAi3FTbuul0JzAPNqidlOSUpboVqiK1abSoqlohtVi1nVS6AxBayQv2edHt7WCO0R9snE2w3txcrs25ByLHJJR-xIz9tGCPMTycKE1mH04xZ5GMEFg1rYQGMkotKBdDSpG2_2QRzPkRZm8Wr-b8CANo8oZM-7rQKLt99BRNcp5GR52POVXTBf9_gWf70ZPF</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2216893080</pqid></control><display><type>article</type><title>Thermodynamic analysis of a 200 MWh electricity storage system based on high temperature thermal energy storage</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Attonaty, Kevin ; Stouffs, Pascal ; Pouvreau, Jérôme ; Oriol, Jean ; Deydier, Alexandre</creator><creatorcontrib>Attonaty, Kevin ; Stouffs, Pascal ; Pouvreau, Jérôme ; Oriol, Jean ; Deydier, Alexandre</creatorcontrib><description>With the increase in the share of intermittent renewable energies as part of the global energy mix comes the issue of energy storage. This work concerns a power-to-power electricity storage relying on sensible storage at high temperature (900 °C). A focus is put on finding the best compromise between the valorization of the stored energy and the optimal functioning of the power-to-power process. The charging loop is made of an electrical heater and fans, while the conversion of the stored heat to electricity can be done in a gas cycle or a combined cycle. To set up a relevant base design for the system, the reciprocal influence of the storage and the discharging cycle needs to be evaluated. A thermodynamic modeling was therefore carried on and first and second law (or exergy) analyses were performed. Results show that the choice of the discharging cycle has a high impact on the sizing of the storage, by inducing different levels of pressure or temperature. Adding combustion in the discharging phase allows to achieve a better power-to-power efficiency and to reduce the storage volume, but also involves a fuel consumption that is not negligible. Finally, the power-to-heat conversion leads to high exergy destructions in the charging loop but thanks to the high temperature of the storage, this exergy destruction is not excessive when compared to conventional heat input from combustion systems. •The round-trip efficiency reaches around 50% in a combined cycle with combustion.•The electricity to heat conversion at 900 °C destroys about 30% of the inlet exergy.•Three possible architectures of the system have been studied.•Energy release in a gas cycle was found to be poorly efficient.•Packed bed thermal storage represents less than 10% of the global exergy destruction.</description><identifier>ISSN: 0360-5442</identifier><identifier>EISSN: 1873-6785</identifier><identifier>DOI: 10.1016/j.energy.2019.01.153</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Charging ; Chemical and Process Engineering ; Combined cycle ; Combined cycle power plant ; Combustion ; Electric energy storage ; Electricity ; Energy conversion efficiency ; Energy storage ; Engineering Sciences ; Exergy ; Exergy analysis ; Heat ; High temperature ; Internal energy ; Packed bed ; Power consumption ; Power efficiency ; Temperature effects ; Thermal energy ; Thermal energy storage ; Thermodynamic models ; Thermodynamics</subject><ispartof>Energy (Oxford), 2019-04, Vol.172, p.1132-1143</ispartof><rights>2019 Elsevier Ltd</rights><rights>Copyright Elsevier BV Apr 1, 2019</rights><rights>Attribution - NonCommercial</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c414t-5c1320ee1b6f78d5d21c41b15c33ec4ae79246e4b85266741e9169d345d002543</citedby><cites>FETCH-LOGICAL-c414t-5c1320ee1b6f78d5d21c41b15c33ec4ae79246e4b85266741e9169d345d002543</cites><orcidid>0000-0003-3920-0205</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.energy.2019.01.153$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://univ-pau.hal.science/hal-02153245$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Attonaty, Kevin</creatorcontrib><creatorcontrib>Stouffs, Pascal</creatorcontrib><creatorcontrib>Pouvreau, Jérôme</creatorcontrib><creatorcontrib>Oriol, Jean</creatorcontrib><creatorcontrib>Deydier, Alexandre</creatorcontrib><title>Thermodynamic analysis of a 200 MWh electricity storage system based on high temperature thermal energy storage</title><title>Energy (Oxford)</title><description>With the increase in the share of intermittent renewable energies as part of the global energy mix comes the issue of energy storage. This work concerns a power-to-power electricity storage relying on sensible storage at high temperature (900 °C). A focus is put on finding the best compromise between the valorization of the stored energy and the optimal functioning of the power-to-power process. The charging loop is made of an electrical heater and fans, while the conversion of the stored heat to electricity can be done in a gas cycle or a combined cycle. To set up a relevant base design for the system, the reciprocal influence of the storage and the discharging cycle needs to be evaluated. A thermodynamic modeling was therefore carried on and first and second law (or exergy) analyses were performed. Results show that the choice of the discharging cycle has a high impact on the sizing of the storage, by inducing different levels of pressure or temperature. Adding combustion in the discharging phase allows to achieve a better power-to-power efficiency and to reduce the storage volume, but also involves a fuel consumption that is not negligible. Finally, the power-to-heat conversion leads to high exergy destructions in the charging loop but thanks to the high temperature of the storage, this exergy destruction is not excessive when compared to conventional heat input from combustion systems. •The round-trip efficiency reaches around 50% in a combined cycle with combustion.•The electricity to heat conversion at 900 °C destroys about 30% of the inlet exergy.•Three possible architectures of the system have been studied.•Energy release in a gas cycle was found to be poorly efficient.•Packed bed thermal storage represents less than 10% of the global exergy destruction.</description><subject>Charging</subject><subject>Chemical and Process Engineering</subject><subject>Combined cycle</subject><subject>Combined cycle power plant</subject><subject>Combustion</subject><subject>Electric energy storage</subject><subject>Electricity</subject><subject>Energy conversion efficiency</subject><subject>Energy storage</subject><subject>Engineering Sciences</subject><subject>Exergy</subject><subject>Exergy analysis</subject><subject>Heat</subject><subject>High temperature</subject><subject>Internal energy</subject><subject>Packed bed</subject><subject>Power consumption</subject><subject>Power efficiency</subject><subject>Temperature effects</subject><subject>Thermal energy</subject><subject>Thermal energy storage</subject><subject>Thermodynamic models</subject><subject>Thermodynamics</subject><issn>0360-5442</issn><issn>1873-6785</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9UctuFDEQtBBILIE_4GCJE4cZuv2YxwUpiiBBWsQlUY6W19O749XseGPPRppb_oh_4kvi1RCOnFrqrqruqmbsI0KJgNWXfUkjxd1cCsC2BCxRy1dshU0ti6pu9Gu2AllBoZUSb9m7lPYAoJu2XbGH257iIXTzaA_ecTvaYU4-8bDllguAP0-_f973nAZyU_TOTzNPU4h2RzzNaaID39hEHQ8j7_2u57lzpGinUyQ-naXtwJfjXnjv2ZutHRJ9-Fsv2N33b7dXN8X61_WPq8t14RSqqdAOpQAi3FTbuul0JzAPNqidlOSUpboVqiK1abSoqlohtVi1nVS6AxBayQv2edHt7WCO0R9snE2w3txcrs25ByLHJJR-xIz9tGCPMTycKE1mH04xZ5GMEFg1rYQGMkotKBdDSpG2_2QRzPkRZm8Wr-b8CANo8oZM-7rQKLt99BRNcp5GR52POVXTBf9_gWf70ZPF</recordid><startdate>20190401</startdate><enddate>20190401</enddate><creator>Attonaty, Kevin</creator><creator>Stouffs, Pascal</creator><creator>Pouvreau, Jérôme</creator><creator>Oriol, Jean</creator><creator>Deydier, Alexandre</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7ST</scope><scope>7TB</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope><scope>SOI</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0003-3920-0205</orcidid></search><sort><creationdate>20190401</creationdate><title>Thermodynamic analysis of a 200 MWh electricity storage system based on high temperature thermal energy storage</title><author>Attonaty, Kevin ; Stouffs, Pascal ; Pouvreau, Jérôme ; Oriol, Jean ; Deydier, Alexandre</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c414t-5c1320ee1b6f78d5d21c41b15c33ec4ae79246e4b85266741e9169d345d002543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Charging</topic><topic>Chemical and Process Engineering</topic><topic>Combined cycle</topic><topic>Combined cycle power plant</topic><topic>Combustion</topic><topic>Electric energy storage</topic><topic>Electricity</topic><topic>Energy conversion efficiency</topic><topic>Energy storage</topic><topic>Engineering Sciences</topic><topic>Exergy</topic><topic>Exergy analysis</topic><topic>Heat</topic><topic>High temperature</topic><topic>Internal energy</topic><topic>Packed bed</topic><topic>Power consumption</topic><topic>Power efficiency</topic><topic>Temperature effects</topic><topic>Thermal energy</topic><topic>Thermal energy storage</topic><topic>Thermodynamic models</topic><topic>Thermodynamics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Attonaty, Kevin</creatorcontrib><creatorcontrib>Stouffs, Pascal</creatorcontrib><creatorcontrib>Pouvreau, Jérôme</creatorcontrib><creatorcontrib>Oriol, Jean</creatorcontrib><creatorcontrib>Deydier, Alexandre</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Environment Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Environment Abstracts</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Energy (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Attonaty, Kevin</au><au>Stouffs, Pascal</au><au>Pouvreau, Jérôme</au><au>Oriol, Jean</au><au>Deydier, Alexandre</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Thermodynamic analysis of a 200 MWh electricity storage system based on high temperature thermal energy storage</atitle><jtitle>Energy (Oxford)</jtitle><date>2019-04-01</date><risdate>2019</risdate><volume>172</volume><spage>1132</spage><epage>1143</epage><pages>1132-1143</pages><issn>0360-5442</issn><eissn>1873-6785</eissn><abstract>With the increase in the share of intermittent renewable energies as part of the global energy mix comes the issue of energy storage. This work concerns a power-to-power electricity storage relying on sensible storage at high temperature (900 °C). A focus is put on finding the best compromise between the valorization of the stored energy and the optimal functioning of the power-to-power process. The charging loop is made of an electrical heater and fans, while the conversion of the stored heat to electricity can be done in a gas cycle or a combined cycle. To set up a relevant base design for the system, the reciprocal influence of the storage and the discharging cycle needs to be evaluated. A thermodynamic modeling was therefore carried on and first and second law (or exergy) analyses were performed. Results show that the choice of the discharging cycle has a high impact on the sizing of the storage, by inducing different levels of pressure or temperature. Adding combustion in the discharging phase allows to achieve a better power-to-power efficiency and to reduce the storage volume, but also involves a fuel consumption that is not negligible. Finally, the power-to-heat conversion leads to high exergy destructions in the charging loop but thanks to the high temperature of the storage, this exergy destruction is not excessive when compared to conventional heat input from combustion systems. •The round-trip efficiency reaches around 50% in a combined cycle with combustion.•The electricity to heat conversion at 900 °C destroys about 30% of the inlet exergy.•Three possible architectures of the system have been studied.•Energy release in a gas cycle was found to be poorly efficient.•Packed bed thermal storage represents less than 10% of the global exergy destruction.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.energy.2019.01.153</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-3920-0205</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0360-5442
ispartof Energy (Oxford), 2019-04, Vol.172, p.1132-1143
issn 0360-5442
1873-6785
language eng
recordid cdi_hal_primary_oai_HAL_hal_02153245v1
source ScienceDirect Journals (5 years ago - present)
subjects Charging
Chemical and Process Engineering
Combined cycle
Combined cycle power plant
Combustion
Electric energy storage
Electricity
Energy conversion efficiency
Energy storage
Engineering Sciences
Exergy
Exergy analysis
Heat
High temperature
Internal energy
Packed bed
Power consumption
Power efficiency
Temperature effects
Thermal energy
Thermal energy storage
Thermodynamic models
Thermodynamics
title Thermodynamic analysis of a 200 MWh electricity storage system based on high temperature thermal energy storage
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T19%3A21%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Thermodynamic%20analysis%20of%20a%20200%E2%80%AFMWh%20electricity%20storage%20system%20based%20on%20high%20temperature%20thermal%20energy%20storage&rft.jtitle=Energy%20(Oxford)&rft.au=Attonaty,%20Kevin&rft.date=2019-04-01&rft.volume=172&rft.spage=1132&rft.epage=1143&rft.pages=1132-1143&rft.issn=0360-5442&rft.eissn=1873-6785&rft_id=info:doi/10.1016/j.energy.2019.01.153&rft_dat=%3Cproquest_hal_p%3E2216893080%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2216893080&rft_id=info:pmid/&rft_els_id=S0360544219301690&rfr_iscdi=true