Non-resonant and non-enhanced Raman correlation spectroscopy
We present the first non-resonant and non-enhanced Raman correlation spectroscopy experiments. They are conducted on a confocal microscope combined with a Raman spectrometer. The thermal fluctuations of the Raman intensities scattered by dispersions of polystyrene particles of sub-micrometric diamet...
Gespeichert in:
Veröffentlicht in: | Optics express 2013-07, Vol.21 (13), p.15418-15429 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 15429 |
---|---|
container_issue | 13 |
container_start_page | 15418 |
container_title | Optics express |
container_volume | 21 |
creator | Barbara, A Dubois, F Quémerais, P Eng, L |
description | We present the first non-resonant and non-enhanced Raman correlation spectroscopy experiments. They are conducted on a confocal microscope combined with a Raman spectrometer. The thermal fluctuations of the Raman intensities scattered by dispersions of polystyrene particles of sub-micrometric diameters are measured and analysed by deriving the autocorrelation functions (ACFs) of the intensities. We show that for particles of diameter down to 200 nm, RCS measurements are successfully obtained in spite of the absence of any source of amplification of the Raman signal. For particles of diameter ranging from 200 to 750 nm, the ACFs present a time-decay behaviour in accordance with the model of free Brownian particles. For particles of 1000 nm in diameter, the AFCs present a different behaviour with a much smaller characteristic time. This results from the dynamics of a single-Brownian particle trapped in the confocal volume by the optical forces of the focus spot. |
doi_str_mv | 10.1364/OE.21.015418 |
format | Article |
fullrecord | <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_02001171v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1399925783</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-c9c3c9aee77bfcc8b1621ae5549ef7584927af82e61b09f0a39fc1fb28c192673</originalsourceid><addsrcrecordid>eNpNkFFLwzAUhYMobk7ffJY-KtiZm6RNAr6MMZ0wHIg-hzRLWKVNatMJ-_d2VIdP93L4OHA-hK4BT4Hm7GG9mBKYYsgYiBM0BixZyrDgp__-EbqI8RNjYFzyczQiVDBCiRyjx9fg09bG4LXvEu03ie8D67faG7tJ3nStfWJC29pKd2XwSWys6doQTWj2l-jM6Sraq987QR9Pi_f5Ml2tn1_ms1VqaE671EhDjdTWcl44Y0QBOQFts4xJ63gmmCRcO0FsDgWWDmsqnQFXEGFAkpzTCbobere6Uk1b1rrdq6BLtZyt1CHDpN8GHL6hZ28HtmnD187GTtVlNLaqtLdhFxVQKSXJuKA9ej-gpt8TW-uO3YDVwa1aLxQBNbjt8Zvf5l1R280R_pNJfwBI2nLt</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1399925783</pqid></control><display><type>article</type><title>Non-resonant and non-enhanced Raman correlation spectroscopy</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Barbara, A ; Dubois, F ; Quémerais, P ; Eng, L</creator><creatorcontrib>Barbara, A ; Dubois, F ; Quémerais, P ; Eng, L</creatorcontrib><description>We present the first non-resonant and non-enhanced Raman correlation spectroscopy experiments. They are conducted on a confocal microscope combined with a Raman spectrometer. The thermal fluctuations of the Raman intensities scattered by dispersions of polystyrene particles of sub-micrometric diameters are measured and analysed by deriving the autocorrelation functions (ACFs) of the intensities. We show that for particles of diameter down to 200 nm, RCS measurements are successfully obtained in spite of the absence of any source of amplification of the Raman signal. For particles of diameter ranging from 200 to 750 nm, the ACFs present a time-decay behaviour in accordance with the model of free Brownian particles. For particles of 1000 nm in diameter, the AFCs present a different behaviour with a much smaller characteristic time. This results from the dynamics of a single-Brownian particle trapped in the confocal volume by the optical forces of the focus spot.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.21.015418</identifier><identifier>PMID: 23842329</identifier><language>eng</language><publisher>United States: Optical Society of America - OSA Publishing</publisher><subject>Optics ; Physics</subject><ispartof>Optics express, 2013-07, Vol.21 (13), p.15418-15429</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c363t-c9c3c9aee77bfcc8b1621ae5549ef7584927af82e61b09f0a39fc1fb28c192673</citedby><cites>FETCH-LOGICAL-c363t-c9c3c9aee77bfcc8b1621ae5549ef7584927af82e61b09f0a39fc1fb28c192673</cites><orcidid>0000-0003-4620-7747</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,864,885,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23842329$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-02001171$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Barbara, A</creatorcontrib><creatorcontrib>Dubois, F</creatorcontrib><creatorcontrib>Quémerais, P</creatorcontrib><creatorcontrib>Eng, L</creatorcontrib><title>Non-resonant and non-enhanced Raman correlation spectroscopy</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>We present the first non-resonant and non-enhanced Raman correlation spectroscopy experiments. They are conducted on a confocal microscope combined with a Raman spectrometer. The thermal fluctuations of the Raman intensities scattered by dispersions of polystyrene particles of sub-micrometric diameters are measured and analysed by deriving the autocorrelation functions (ACFs) of the intensities. We show that for particles of diameter down to 200 nm, RCS measurements are successfully obtained in spite of the absence of any source of amplification of the Raman signal. For particles of diameter ranging from 200 to 750 nm, the ACFs present a time-decay behaviour in accordance with the model of free Brownian particles. For particles of 1000 nm in diameter, the AFCs present a different behaviour with a much smaller characteristic time. This results from the dynamics of a single-Brownian particle trapped in the confocal volume by the optical forces of the focus spot.</description><subject>Optics</subject><subject>Physics</subject><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNpNkFFLwzAUhYMobk7ffJY-KtiZm6RNAr6MMZ0wHIg-hzRLWKVNatMJ-_d2VIdP93L4OHA-hK4BT4Hm7GG9mBKYYsgYiBM0BixZyrDgp__-EbqI8RNjYFzyczQiVDBCiRyjx9fg09bG4LXvEu03ie8D67faG7tJ3nStfWJC29pKd2XwSWys6doQTWj2l-jM6Sraq987QR9Pi_f5Ml2tn1_ms1VqaE671EhDjdTWcl44Y0QBOQFts4xJ63gmmCRcO0FsDgWWDmsqnQFXEGFAkpzTCbobere6Uk1b1rrdq6BLtZyt1CHDpN8GHL6hZ28HtmnD187GTtVlNLaqtLdhFxVQKSXJuKA9ej-gpt8TW-uO3YDVwa1aLxQBNbjt8Zvf5l1R280R_pNJfwBI2nLt</recordid><startdate>20130701</startdate><enddate>20130701</enddate><creator>Barbara, A</creator><creator>Dubois, F</creator><creator>Quémerais, P</creator><creator>Eng, L</creator><general>Optical Society of America - OSA Publishing</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0003-4620-7747</orcidid></search><sort><creationdate>20130701</creationdate><title>Non-resonant and non-enhanced Raman correlation spectroscopy</title><author>Barbara, A ; Dubois, F ; Quémerais, P ; Eng, L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-c9c3c9aee77bfcc8b1621ae5549ef7584927af82e61b09f0a39fc1fb28c192673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Optics</topic><topic>Physics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Barbara, A</creatorcontrib><creatorcontrib>Dubois, F</creatorcontrib><creatorcontrib>Quémerais, P</creatorcontrib><creatorcontrib>Eng, L</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Barbara, A</au><au>Dubois, F</au><au>Quémerais, P</au><au>Eng, L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Non-resonant and non-enhanced Raman correlation spectroscopy</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2013-07-01</date><risdate>2013</risdate><volume>21</volume><issue>13</issue><spage>15418</spage><epage>15429</epage><pages>15418-15429</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>We present the first non-resonant and non-enhanced Raman correlation spectroscopy experiments. They are conducted on a confocal microscope combined with a Raman spectrometer. The thermal fluctuations of the Raman intensities scattered by dispersions of polystyrene particles of sub-micrometric diameters are measured and analysed by deriving the autocorrelation functions (ACFs) of the intensities. We show that for particles of diameter down to 200 nm, RCS measurements are successfully obtained in spite of the absence of any source of amplification of the Raman signal. For particles of diameter ranging from 200 to 750 nm, the ACFs present a time-decay behaviour in accordance with the model of free Brownian particles. For particles of 1000 nm in diameter, the AFCs present a different behaviour with a much smaller characteristic time. This results from the dynamics of a single-Brownian particle trapped in the confocal volume by the optical forces of the focus spot.</abstract><cop>United States</cop><pub>Optical Society of America - OSA Publishing</pub><pmid>23842329</pmid><doi>10.1364/OE.21.015418</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-4620-7747</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1094-4087 |
ispartof | Optics express, 2013-07, Vol.21 (13), p.15418-15429 |
issn | 1094-4087 1094-4087 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_02001171v1 |
source | DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection |
subjects | Optics Physics |
title | Non-resonant and non-enhanced Raman correlation spectroscopy |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T05%3A17%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Non-resonant%20and%20non-enhanced%20Raman%20correlation%20spectroscopy&rft.jtitle=Optics%20express&rft.au=Barbara,%20A&rft.date=2013-07-01&rft.volume=21&rft.issue=13&rft.spage=15418&rft.epage=15429&rft.pages=15418-15429&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.21.015418&rft_dat=%3Cproquest_hal_p%3E1399925783%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1399925783&rft_id=info:pmid/23842329&rfr_iscdi=true |