Mass transport and fractionation during monazite alteration by anisotropic replacement

The present experimental study investigates the causes of anisotropic replacement and its impact on the element mass transfer during monazite alteration by combining in situ characterization of solid and fluid products. Starting material of standard Manangotry monazite was placed at 200MPa with 18O...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical geology 2018-05, Vol.484, p.51-68
Hauptverfasser: Grand'Homme, A., Janots, E., Seydoux-Guillaume, A.M., Guillaume, D., Magnin, V., Hövelmann, J., Höschen, C., Boiron, M.C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 68
container_issue
container_start_page 51
container_title Chemical geology
container_volume 484
creator Grand'Homme, A.
Janots, E.
Seydoux-Guillaume, A.M.
Guillaume, D.
Magnin, V.
Hövelmann, J.
Höschen, C.
Boiron, M.C.
description The present experimental study investigates the causes of anisotropic replacement and its impact on the element mass transfer during monazite alteration by combining in situ characterization of solid and fluid products. Starting material of standard Manangotry monazite was placed at 200MPa with 18O doped fluids, at temperature (T) between 300 and 600°C, for durations between 14 and 114days, in some cases with hematite-magnetite buffer, and in presence of pre-fractured quartz crystals. For all experiments with NaOH at T>400°C, monazite products show a replacement rim (altered domain), but with complex microstructures that are best explained by nanoscale observations. At 400°C (and 500°C), replacement propagates anisotropically through the unaltered domain, due to preferentially oriented dissolution and/or fracturing at the reaction interface. The altered domain corresponds to nanochannels of secondary monazite (Mnz2) intruding primary monazite (Mnz1), with nanopores filled by amorphous Si-rich inclusions at the reaction front (interface). At 600°C, the altered domain increases in volume and becomes homogeneous and non-porous, due to textural (and chemical) reequilibration. However, nanoscale observations reveal an anisotropic propagation associated with dislocations and preservation of Mnz1 relics within the apparently homogeneous altered domain. Textural equilibration leads to transient pores/inclusions, which preferentially move toward the reaction front. In all experimental products, the abundant porosity attests to significant mass transfer during monazite replacement. Nanomixture within altered domains hampers accurate determination of Mnz2 composition, and is assumed to be responsible for the Pb measured in the rim, due to Mnz1 contribution. However, composition measurements indicate that Mnz2 contains higher light rare earth elements (LREE), higher Th/U ratio but lower Y, Th, U, Pb and Ca contents compared to Mnz1. Elements released in the fluid by monazite replacement are mobilized from the reaction front toward the grain boundary, and then redistributed between secondary Th-silicates and phosphates, Si-rich gel-like material and aqueous fluids. At T>500°C, analyses of inclusions trapped in replaced quartz confirm an efficient REE solubility in the alkaline solutions. The Si-rich gel-like inclusions contain high amounts of REE (e.g. 950–4600ppm Ce), Th (4480–6170ppm) and U (30–110ppm), while aqueous fluid inclusions have high concentrations of REE a
doi_str_mv 10.1016/j.chemgeo.2017.10.008
format Article
fullrecord <record><control><sourceid>elsevier_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_01904674v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0009254117305636</els_id><sourcerecordid>S0009254117305636</sourcerecordid><originalsourceid>FETCH-LOGICAL-a366t-591a8ab2ae864e42f022ec1972d928d91e6f34b2b8da96136f0ff7b25a98b6c3</originalsourceid><addsrcrecordid>eNqFUE1LxDAUDKLguvoThF49tCZpmzYnWRZ1hRUvi9fwmr7uZukXSVxYf70pFa9e3mPmzQy8IeSe0YRRJh6PiT5gt8ch4ZQVgUsoLS_IgpUFj0WZikuyoJTKmOcZuyY3zh0DZGmeL8jnOzgXeQu9GwfrI-jrqLGgvRl6mEZUf1nT76Mu4G_jMYLWo51P1TnojRu8HUajI4tjCxo77P0tuWqgdXj3u5dk9_K8W2_i7cfr23q1jSEVwse5ZFBCxQFLkWHGG8o5aiYLXkte1pKhaNKs4lVZgxQsFQ1tmqLiOciyEjpdkoc59gCtGq3pwJ7VAEZtVls1cZRJmokiO7GgzWettoNzFps_A6Nq6lEd1W-PaupxokOPwfc0-zD8cTJoldMGe421sai9qgfzT8IPDcV_9Q</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Mass transport and fractionation during monazite alteration by anisotropic replacement</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Grand'Homme, A. ; Janots, E. ; Seydoux-Guillaume, A.M. ; Guillaume, D. ; Magnin, V. ; Hövelmann, J. ; Höschen, C. ; Boiron, M.C.</creator><creatorcontrib>Grand'Homme, A. ; Janots, E. ; Seydoux-Guillaume, A.M. ; Guillaume, D. ; Magnin, V. ; Hövelmann, J. ; Höschen, C. ; Boiron, M.C.</creatorcontrib><description>The present experimental study investigates the causes of anisotropic replacement and its impact on the element mass transfer during monazite alteration by combining in situ characterization of solid and fluid products. Starting material of standard Manangotry monazite was placed at 200MPa with 18O doped fluids, at temperature (T) between 300 and 600°C, for durations between 14 and 114days, in some cases with hematite-magnetite buffer, and in presence of pre-fractured quartz crystals. For all experiments with NaOH at T&gt;400°C, monazite products show a replacement rim (altered domain), but with complex microstructures that are best explained by nanoscale observations. At 400°C (and 500°C), replacement propagates anisotropically through the unaltered domain, due to preferentially oriented dissolution and/or fracturing at the reaction interface. The altered domain corresponds to nanochannels of secondary monazite (Mnz2) intruding primary monazite (Mnz1), with nanopores filled by amorphous Si-rich inclusions at the reaction front (interface). At 600°C, the altered domain increases in volume and becomes homogeneous and non-porous, due to textural (and chemical) reequilibration. However, nanoscale observations reveal an anisotropic propagation associated with dislocations and preservation of Mnz1 relics within the apparently homogeneous altered domain. Textural equilibration leads to transient pores/inclusions, which preferentially move toward the reaction front. In all experimental products, the abundant porosity attests to significant mass transfer during monazite replacement. Nanomixture within altered domains hampers accurate determination of Mnz2 composition, and is assumed to be responsible for the Pb measured in the rim, due to Mnz1 contribution. However, composition measurements indicate that Mnz2 contains higher light rare earth elements (LREE), higher Th/U ratio but lower Y, Th, U, Pb and Ca contents compared to Mnz1. Elements released in the fluid by monazite replacement are mobilized from the reaction front toward the grain boundary, and then redistributed between secondary Th-silicates and phosphates, Si-rich gel-like material and aqueous fluids. At T&gt;500°C, analyses of inclusions trapped in replaced quartz confirm an efficient REE solubility in the alkaline solutions. The Si-rich gel-like inclusions contain high amounts of REE (e.g. 950–4600ppm Ce), Th (4480–6170ppm) and U (30–110ppm), while aqueous fluid inclusions have high concentrations of REE and Th (around 100s of ppm) compared to common natural brines. There is a fractionation of Th and U during Mnz1 replacement (Th/U ~70) with low Th/U ratios in the aqueous fluid (7–23) compared to the secondary solid products (up to 150), independently of the initial presence of hematite-magnetite buffer. This accounts for a fractionation within the isotopic Th-Pb and U-Pb ages within the altered domain. In natural samples observed microscopically, the complex anisotropic geometry of the replacement can lead to a nanomixture within apparently homogeneous altered domains (with partial resetting of the U-Th-Pb geochronometer), and to misleading interpretations of secondary inclusions within apparently unaltered domain. •Anisotropic propagation of the reaction front during monazite alteration (&lt;600°C)•Anisotropic replacement leads to a nanomixture of Mnz1+Mnz2 in the altered domain.•Nanomixture in the altered domain can reproduce incomplete U-Th-Pb age resetting.•Apparent precipitation of secondary inclusions within unaltered domain at microscale•Unidentified nanomixtures may lead to data spreading and to age misinterpretation.</description><identifier>ISSN: 0009-2541</identifier><identifier>EISSN: 1872-6836</identifier><identifier>DOI: 10.1016/j.chemgeo.2017.10.008</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Anisotropic replacement ; Earth Sciences ; Experimental alteration ; Fluid inclusions ; Geochemistry ; Mineralogy ; Monazite ; Nanoscale observations (TEM) ; Sciences of the Universe ; Structural defects</subject><ispartof>Chemical geology, 2018-05, Vol.484, p.51-68</ispartof><rights>2017 Elsevier B.V.</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a366t-591a8ab2ae864e42f022ec1972d928d91e6f34b2b8da96136f0ff7b25a98b6c3</citedby><cites>FETCH-LOGICAL-a366t-591a8ab2ae864e42f022ec1972d928d91e6f34b2b8da96136f0ff7b25a98b6c3</cites><orcidid>0000-0001-7283-6200 ; 0000-0002-9921-4695 ; 0000-0001-5232-8380</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0009254117305636$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,776,780,881,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://hal.science/hal-01904674$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Grand'Homme, A.</creatorcontrib><creatorcontrib>Janots, E.</creatorcontrib><creatorcontrib>Seydoux-Guillaume, A.M.</creatorcontrib><creatorcontrib>Guillaume, D.</creatorcontrib><creatorcontrib>Magnin, V.</creatorcontrib><creatorcontrib>Hövelmann, J.</creatorcontrib><creatorcontrib>Höschen, C.</creatorcontrib><creatorcontrib>Boiron, M.C.</creatorcontrib><title>Mass transport and fractionation during monazite alteration by anisotropic replacement</title><title>Chemical geology</title><description>The present experimental study investigates the causes of anisotropic replacement and its impact on the element mass transfer during monazite alteration by combining in situ characterization of solid and fluid products. Starting material of standard Manangotry monazite was placed at 200MPa with 18O doped fluids, at temperature (T) between 300 and 600°C, for durations between 14 and 114days, in some cases with hematite-magnetite buffer, and in presence of pre-fractured quartz crystals. For all experiments with NaOH at T&gt;400°C, monazite products show a replacement rim (altered domain), but with complex microstructures that are best explained by nanoscale observations. At 400°C (and 500°C), replacement propagates anisotropically through the unaltered domain, due to preferentially oriented dissolution and/or fracturing at the reaction interface. The altered domain corresponds to nanochannels of secondary monazite (Mnz2) intruding primary monazite (Mnz1), with nanopores filled by amorphous Si-rich inclusions at the reaction front (interface). At 600°C, the altered domain increases in volume and becomes homogeneous and non-porous, due to textural (and chemical) reequilibration. However, nanoscale observations reveal an anisotropic propagation associated with dislocations and preservation of Mnz1 relics within the apparently homogeneous altered domain. Textural equilibration leads to transient pores/inclusions, which preferentially move toward the reaction front. In all experimental products, the abundant porosity attests to significant mass transfer during monazite replacement. Nanomixture within altered domains hampers accurate determination of Mnz2 composition, and is assumed to be responsible for the Pb measured in the rim, due to Mnz1 contribution. However, composition measurements indicate that Mnz2 contains higher light rare earth elements (LREE), higher Th/U ratio but lower Y, Th, U, Pb and Ca contents compared to Mnz1. Elements released in the fluid by monazite replacement are mobilized from the reaction front toward the grain boundary, and then redistributed between secondary Th-silicates and phosphates, Si-rich gel-like material and aqueous fluids. At T&gt;500°C, analyses of inclusions trapped in replaced quartz confirm an efficient REE solubility in the alkaline solutions. The Si-rich gel-like inclusions contain high amounts of REE (e.g. 950–4600ppm Ce), Th (4480–6170ppm) and U (30–110ppm), while aqueous fluid inclusions have high concentrations of REE and Th (around 100s of ppm) compared to common natural brines. There is a fractionation of Th and U during Mnz1 replacement (Th/U ~70) with low Th/U ratios in the aqueous fluid (7–23) compared to the secondary solid products (up to 150), independently of the initial presence of hematite-magnetite buffer. This accounts for a fractionation within the isotopic Th-Pb and U-Pb ages within the altered domain. In natural samples observed microscopically, the complex anisotropic geometry of the replacement can lead to a nanomixture within apparently homogeneous altered domains (with partial resetting of the U-Th-Pb geochronometer), and to misleading interpretations of secondary inclusions within apparently unaltered domain. •Anisotropic propagation of the reaction front during monazite alteration (&lt;600°C)•Anisotropic replacement leads to a nanomixture of Mnz1+Mnz2 in the altered domain.•Nanomixture in the altered domain can reproduce incomplete U-Th-Pb age resetting.•Apparent precipitation of secondary inclusions within unaltered domain at microscale•Unidentified nanomixtures may lead to data spreading and to age misinterpretation.</description><subject>Anisotropic replacement</subject><subject>Earth Sciences</subject><subject>Experimental alteration</subject><subject>Fluid inclusions</subject><subject>Geochemistry</subject><subject>Mineralogy</subject><subject>Monazite</subject><subject>Nanoscale observations (TEM)</subject><subject>Sciences of the Universe</subject><subject>Structural defects</subject><issn>0009-2541</issn><issn>1872-6836</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFUE1LxDAUDKLguvoThF49tCZpmzYnWRZ1hRUvi9fwmr7uZukXSVxYf70pFa9e3mPmzQy8IeSe0YRRJh6PiT5gt8ch4ZQVgUsoLS_IgpUFj0WZikuyoJTKmOcZuyY3zh0DZGmeL8jnOzgXeQu9GwfrI-jrqLGgvRl6mEZUf1nT76Mu4G_jMYLWo51P1TnojRu8HUajI4tjCxo77P0tuWqgdXj3u5dk9_K8W2_i7cfr23q1jSEVwse5ZFBCxQFLkWHGG8o5aiYLXkte1pKhaNKs4lVZgxQsFQ1tmqLiOciyEjpdkoc59gCtGq3pwJ7VAEZtVls1cZRJmokiO7GgzWettoNzFps_A6Nq6lEd1W-PaupxokOPwfc0-zD8cTJoldMGe421sai9qgfzT8IPDcV_9Q</recordid><startdate>20180505</startdate><enddate>20180505</enddate><creator>Grand'Homme, A.</creator><creator>Janots, E.</creator><creator>Seydoux-Guillaume, A.M.</creator><creator>Guillaume, D.</creator><creator>Magnin, V.</creator><creator>Hövelmann, J.</creator><creator>Höschen, C.</creator><creator>Boiron, M.C.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><orcidid>https://orcid.org/0000-0001-7283-6200</orcidid><orcidid>https://orcid.org/0000-0002-9921-4695</orcidid><orcidid>https://orcid.org/0000-0001-5232-8380</orcidid></search><sort><creationdate>20180505</creationdate><title>Mass transport and fractionation during monazite alteration by anisotropic replacement</title><author>Grand'Homme, A. ; Janots, E. ; Seydoux-Guillaume, A.M. ; Guillaume, D. ; Magnin, V. ; Hövelmann, J. ; Höschen, C. ; Boiron, M.C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a366t-591a8ab2ae864e42f022ec1972d928d91e6f34b2b8da96136f0ff7b25a98b6c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Anisotropic replacement</topic><topic>Earth Sciences</topic><topic>Experimental alteration</topic><topic>Fluid inclusions</topic><topic>Geochemistry</topic><topic>Mineralogy</topic><topic>Monazite</topic><topic>Nanoscale observations (TEM)</topic><topic>Sciences of the Universe</topic><topic>Structural defects</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Grand'Homme, A.</creatorcontrib><creatorcontrib>Janots, E.</creatorcontrib><creatorcontrib>Seydoux-Guillaume, A.M.</creatorcontrib><creatorcontrib>Guillaume, D.</creatorcontrib><creatorcontrib>Magnin, V.</creatorcontrib><creatorcontrib>Hövelmann, J.</creatorcontrib><creatorcontrib>Höschen, C.</creatorcontrib><creatorcontrib>Boiron, M.C.</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Chemical geology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Grand'Homme, A.</au><au>Janots, E.</au><au>Seydoux-Guillaume, A.M.</au><au>Guillaume, D.</au><au>Magnin, V.</au><au>Hövelmann, J.</au><au>Höschen, C.</au><au>Boiron, M.C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Mass transport and fractionation during monazite alteration by anisotropic replacement</atitle><jtitle>Chemical geology</jtitle><date>2018-05-05</date><risdate>2018</risdate><volume>484</volume><spage>51</spage><epage>68</epage><pages>51-68</pages><issn>0009-2541</issn><eissn>1872-6836</eissn><abstract>The present experimental study investigates the causes of anisotropic replacement and its impact on the element mass transfer during monazite alteration by combining in situ characterization of solid and fluid products. Starting material of standard Manangotry monazite was placed at 200MPa with 18O doped fluids, at temperature (T) between 300 and 600°C, for durations between 14 and 114days, in some cases with hematite-magnetite buffer, and in presence of pre-fractured quartz crystals. For all experiments with NaOH at T&gt;400°C, monazite products show a replacement rim (altered domain), but with complex microstructures that are best explained by nanoscale observations. At 400°C (and 500°C), replacement propagates anisotropically through the unaltered domain, due to preferentially oriented dissolution and/or fracturing at the reaction interface. The altered domain corresponds to nanochannels of secondary monazite (Mnz2) intruding primary monazite (Mnz1), with nanopores filled by amorphous Si-rich inclusions at the reaction front (interface). At 600°C, the altered domain increases in volume and becomes homogeneous and non-porous, due to textural (and chemical) reequilibration. However, nanoscale observations reveal an anisotropic propagation associated with dislocations and preservation of Mnz1 relics within the apparently homogeneous altered domain. Textural equilibration leads to transient pores/inclusions, which preferentially move toward the reaction front. In all experimental products, the abundant porosity attests to significant mass transfer during monazite replacement. Nanomixture within altered domains hampers accurate determination of Mnz2 composition, and is assumed to be responsible for the Pb measured in the rim, due to Mnz1 contribution. However, composition measurements indicate that Mnz2 contains higher light rare earth elements (LREE), higher Th/U ratio but lower Y, Th, U, Pb and Ca contents compared to Mnz1. Elements released in the fluid by monazite replacement are mobilized from the reaction front toward the grain boundary, and then redistributed between secondary Th-silicates and phosphates, Si-rich gel-like material and aqueous fluids. At T&gt;500°C, analyses of inclusions trapped in replaced quartz confirm an efficient REE solubility in the alkaline solutions. The Si-rich gel-like inclusions contain high amounts of REE (e.g. 950–4600ppm Ce), Th (4480–6170ppm) and U (30–110ppm), while aqueous fluid inclusions have high concentrations of REE and Th (around 100s of ppm) compared to common natural brines. There is a fractionation of Th and U during Mnz1 replacement (Th/U ~70) with low Th/U ratios in the aqueous fluid (7–23) compared to the secondary solid products (up to 150), independently of the initial presence of hematite-magnetite buffer. This accounts for a fractionation within the isotopic Th-Pb and U-Pb ages within the altered domain. In natural samples observed microscopically, the complex anisotropic geometry of the replacement can lead to a nanomixture within apparently homogeneous altered domains (with partial resetting of the U-Th-Pb geochronometer), and to misleading interpretations of secondary inclusions within apparently unaltered domain. •Anisotropic propagation of the reaction front during monazite alteration (&lt;600°C)•Anisotropic replacement leads to a nanomixture of Mnz1+Mnz2 in the altered domain.•Nanomixture in the altered domain can reproduce incomplete U-Th-Pb age resetting.•Apparent precipitation of secondary inclusions within unaltered domain at microscale•Unidentified nanomixtures may lead to data spreading and to age misinterpretation.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.chemgeo.2017.10.008</doi><tpages>18</tpages><orcidid>https://orcid.org/0000-0001-7283-6200</orcidid><orcidid>https://orcid.org/0000-0002-9921-4695</orcidid><orcidid>https://orcid.org/0000-0001-5232-8380</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0009-2541
ispartof Chemical geology, 2018-05, Vol.484, p.51-68
issn 0009-2541
1872-6836
language eng
recordid cdi_hal_primary_oai_HAL_hal_01904674v1
source Elsevier ScienceDirect Journals Complete
subjects Anisotropic replacement
Earth Sciences
Experimental alteration
Fluid inclusions
Geochemistry
Mineralogy
Monazite
Nanoscale observations (TEM)
Sciences of the Universe
Structural defects
title Mass transport and fractionation during monazite alteration by anisotropic replacement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T15%3A31%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Mass%20transport%20and%20fractionation%20during%20monazite%20alteration%20by%20anisotropic%20replacement&rft.jtitle=Chemical%20geology&rft.au=Grand'Homme,%20A.&rft.date=2018-05-05&rft.volume=484&rft.spage=51&rft.epage=68&rft.pages=51-68&rft.issn=0009-2541&rft.eissn=1872-6836&rft_id=info:doi/10.1016/j.chemgeo.2017.10.008&rft_dat=%3Celsevier_hal_p%3ES0009254117305636%3C/elsevier_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S0009254117305636&rfr_iscdi=true