How to: Measuring blood cytokines in biological psychiatry using commercially available multiplex immunoassays
Highlights • We compared two multiplex-cytokine detection technologies. • Both platforms performances were unequal depending on tested cytokines. • Healthy state is not synonymous of stability in blood circulating cytokines. • Caution is required to profile body fluid with multiplex technologies....
Gespeichert in:
Veröffentlicht in: | Psychoneuroendocrinology 2017-01, Vol.75, p.72-82 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 82 |
---|---|
container_issue | |
container_start_page | 72 |
container_title | Psychoneuroendocrinology |
container_volume | 75 |
creator | Belzeaux, Raoul Lefebvre, Marie-Noëlle Lazzari, Anne Le Carpentier, Tifenn Consoloni, Julia-Lou Zendjidjian, Xavier Abbar, Mocrane Courtet, Philippe Naudin, Jean Boucraut, José Gressens, Pierre Glaichenhaus, Nicolas Ibrahim, El Chérif |
description | Highlights • We compared two multiplex-cytokine detection technologies. • Both platforms performances were unequal depending on tested cytokines. • Healthy state is not synonymous of stability in blood circulating cytokines. • Caution is required to profile body fluid with multiplex technologies. |
doi_str_mv | 10.1016/j.psyneuen.2016.10.010 |
format | Article |
fullrecord | <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_01575039v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0306453016308022</els_id><sourcerecordid>1836735994</sourcerecordid><originalsourceid>FETCH-LOGICAL-c641t-4da250be82f661d3502755d108a1f466c03599167c251cf98468f12de4a107e63</originalsourceid><addsrcrecordid>eNqFkkFv1DAQhS0EokvhL1Q-wiHbsZ04WQ6IqgIWaREH4Gw5zqT11rEXO1maf4-jbXvgwsny6Jv3NPOGkAsGawZMXu7XhzR7nNCvef7n4hoYPCMr1tSiEELCc7ICAbIoKwFn5FVKewCQjeQvyRmvGwY1yBXx2_CHjuE9_YY6TdH6G9q6EDpq5jHcWY-JWk9bG1y4sUY7mm3NrdVjnOmUFtyEYcBorHZupvqordOtQzpMbrQHh_fUDsPkg05Jz-k1edFrl_DNw3tOfn3-9PN6W-y-f_l6fbUrjCzZWJSd5hW02PBeStaJCnhdVR2DRrO-lNKAqDYbJmvDK2b6TVPKpme8w1LnuVCKc_LupHurnTpEO-g4q6Ct2l7t1FIDVtUViM2RZfbtiT3E8HvCNKrBJoPOaY9hSoo1QtaLX5lReUJNDClF7J-0GaglF7VXj7moJZelnnPJjRcPHlM7YPfU9hhEBj6eAMxbOVqMKhmL3mBnI5pRdcH-3-PDPxLGWb-Edoczpn2Yos87V0wlrkD9WK5jOQ4mBTTAufgLGXK3sQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1836735994</pqid></control><display><type>article</type><title>How to: Measuring blood cytokines in biological psychiatry using commercially available multiplex immunoassays</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Belzeaux, Raoul ; Lefebvre, Marie-Noëlle ; Lazzari, Anne ; Le Carpentier, Tifenn ; Consoloni, Julia-Lou ; Zendjidjian, Xavier ; Abbar, Mocrane ; Courtet, Philippe ; Naudin, Jean ; Boucraut, José ; Gressens, Pierre ; Glaichenhaus, Nicolas ; Ibrahim, El Chérif</creator><creatorcontrib>Belzeaux, Raoul ; Lefebvre, Marie-Noëlle ; Lazzari, Anne ; Le Carpentier, Tifenn ; Consoloni, Julia-Lou ; Zendjidjian, Xavier ; Abbar, Mocrane ; Courtet, Philippe ; Naudin, Jean ; Boucraut, José ; Gressens, Pierre ; Glaichenhaus, Nicolas ; Ibrahim, El Chérif</creatorcontrib><description>Highlights • We compared two multiplex-cytokine detection technologies. • Both platforms performances were unequal depending on tested cytokines. • Healthy state is not synonymous of stability in blood circulating cytokines. • Caution is required to profile body fluid with multiplex technologies.</description><identifier>ISSN: 0306-4530</identifier><identifier>EISSN: 1873-3360</identifier><identifier>DOI: 10.1016/j.psyneuen.2016.10.010</identifier><identifier>PMID: 27810706</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Biochemistry, Molecular Biology ; Cytokine ; Endocrinology & Metabolism ; Genomics ; Human health and pathology ; Inflammation ; Life Sciences ; Multiplex immunoassay ; Psychiatrics and mental health ; Psychiatry</subject><ispartof>Psychoneuroendocrinology, 2017-01, Vol.75, p.72-82</ispartof><rights>Elsevier Ltd</rights><rights>2016 Elsevier Ltd</rights><rights>Copyright © 2016 Elsevier Ltd. All rights reserved.</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c641t-4da250be82f661d3502755d108a1f466c03599167c251cf98468f12de4a107e63</citedby><cites>FETCH-LOGICAL-c641t-4da250be82f661d3502755d108a1f466c03599167c251cf98468f12de4a107e63</cites><orcidid>0000-0002-6519-8586 ; 0000-0002-8997-0470 ; 0000-0003-1222-6050 ; 0000-0002-0909-4221</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.psyneuen.2016.10.010$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27810706$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://amu.hal.science/hal-01575039$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Belzeaux, Raoul</creatorcontrib><creatorcontrib>Lefebvre, Marie-Noëlle</creatorcontrib><creatorcontrib>Lazzari, Anne</creatorcontrib><creatorcontrib>Le Carpentier, Tifenn</creatorcontrib><creatorcontrib>Consoloni, Julia-Lou</creatorcontrib><creatorcontrib>Zendjidjian, Xavier</creatorcontrib><creatorcontrib>Abbar, Mocrane</creatorcontrib><creatorcontrib>Courtet, Philippe</creatorcontrib><creatorcontrib>Naudin, Jean</creatorcontrib><creatorcontrib>Boucraut, José</creatorcontrib><creatorcontrib>Gressens, Pierre</creatorcontrib><creatorcontrib>Glaichenhaus, Nicolas</creatorcontrib><creatorcontrib>Ibrahim, El Chérif</creatorcontrib><title>How to: Measuring blood cytokines in biological psychiatry using commercially available multiplex immunoassays</title><title>Psychoneuroendocrinology</title><addtitle>Psychoneuroendocrinology</addtitle><description>Highlights • We compared two multiplex-cytokine detection technologies. • Both platforms performances were unequal depending on tested cytokines. • Healthy state is not synonymous of stability in blood circulating cytokines. • Caution is required to profile body fluid with multiplex technologies.</description><subject>Biochemistry, Molecular Biology</subject><subject>Cytokine</subject><subject>Endocrinology & Metabolism</subject><subject>Genomics</subject><subject>Human health and pathology</subject><subject>Inflammation</subject><subject>Life Sciences</subject><subject>Multiplex immunoassay</subject><subject>Psychiatrics and mental health</subject><subject>Psychiatry</subject><issn>0306-4530</issn><issn>1873-3360</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqFkkFv1DAQhS0EokvhL1Q-wiHbsZ04WQ6IqgIWaREH4Gw5zqT11rEXO1maf4-jbXvgwsny6Jv3NPOGkAsGawZMXu7XhzR7nNCvef7n4hoYPCMr1tSiEELCc7ICAbIoKwFn5FVKewCQjeQvyRmvGwY1yBXx2_CHjuE9_YY6TdH6G9q6EDpq5jHcWY-JWk9bG1y4sUY7mm3NrdVjnOmUFtyEYcBorHZupvqordOtQzpMbrQHh_fUDsPkg05Jz-k1edFrl_DNw3tOfn3-9PN6W-y-f_l6fbUrjCzZWJSd5hW02PBeStaJCnhdVR2DRrO-lNKAqDYbJmvDK2b6TVPKpme8w1LnuVCKc_LupHurnTpEO-g4q6Ct2l7t1FIDVtUViM2RZfbtiT3E8HvCNKrBJoPOaY9hSoo1QtaLX5lReUJNDClF7J-0GaglF7VXj7moJZelnnPJjRcPHlM7YPfU9hhEBj6eAMxbOVqMKhmL3mBnI5pRdcH-3-PDPxLGWb-Edoczpn2Yos87V0wlrkD9WK5jOQ4mBTTAufgLGXK3sQ</recordid><startdate>20170101</startdate><enddate>20170101</enddate><creator>Belzeaux, Raoul</creator><creator>Lefebvre, Marie-Noëlle</creator><creator>Lazzari, Anne</creator><creator>Le Carpentier, Tifenn</creator><creator>Consoloni, Julia-Lou</creator><creator>Zendjidjian, Xavier</creator><creator>Abbar, Mocrane</creator><creator>Courtet, Philippe</creator><creator>Naudin, Jean</creator><creator>Boucraut, José</creator><creator>Gressens, Pierre</creator><creator>Glaichenhaus, Nicolas</creator><creator>Ibrahim, El Chérif</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0002-6519-8586</orcidid><orcidid>https://orcid.org/0000-0002-8997-0470</orcidid><orcidid>https://orcid.org/0000-0003-1222-6050</orcidid><orcidid>https://orcid.org/0000-0002-0909-4221</orcidid></search><sort><creationdate>20170101</creationdate><title>How to: Measuring blood cytokines in biological psychiatry using commercially available multiplex immunoassays</title><author>Belzeaux, Raoul ; Lefebvre, Marie-Noëlle ; Lazzari, Anne ; Le Carpentier, Tifenn ; Consoloni, Julia-Lou ; Zendjidjian, Xavier ; Abbar, Mocrane ; Courtet, Philippe ; Naudin, Jean ; Boucraut, José ; Gressens, Pierre ; Glaichenhaus, Nicolas ; Ibrahim, El Chérif</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c641t-4da250be82f661d3502755d108a1f466c03599167c251cf98468f12de4a107e63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Biochemistry, Molecular Biology</topic><topic>Cytokine</topic><topic>Endocrinology & Metabolism</topic><topic>Genomics</topic><topic>Human health and pathology</topic><topic>Inflammation</topic><topic>Life Sciences</topic><topic>Multiplex immunoassay</topic><topic>Psychiatrics and mental health</topic><topic>Psychiatry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Belzeaux, Raoul</creatorcontrib><creatorcontrib>Lefebvre, Marie-Noëlle</creatorcontrib><creatorcontrib>Lazzari, Anne</creatorcontrib><creatorcontrib>Le Carpentier, Tifenn</creatorcontrib><creatorcontrib>Consoloni, Julia-Lou</creatorcontrib><creatorcontrib>Zendjidjian, Xavier</creatorcontrib><creatorcontrib>Abbar, Mocrane</creatorcontrib><creatorcontrib>Courtet, Philippe</creatorcontrib><creatorcontrib>Naudin, Jean</creatorcontrib><creatorcontrib>Boucraut, José</creatorcontrib><creatorcontrib>Gressens, Pierre</creatorcontrib><creatorcontrib>Glaichenhaus, Nicolas</creatorcontrib><creatorcontrib>Ibrahim, El Chérif</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Psychoneuroendocrinology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Belzeaux, Raoul</au><au>Lefebvre, Marie-Noëlle</au><au>Lazzari, Anne</au><au>Le Carpentier, Tifenn</au><au>Consoloni, Julia-Lou</au><au>Zendjidjian, Xavier</au><au>Abbar, Mocrane</au><au>Courtet, Philippe</au><au>Naudin, Jean</au><au>Boucraut, José</au><au>Gressens, Pierre</au><au>Glaichenhaus, Nicolas</au><au>Ibrahim, El Chérif</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>How to: Measuring blood cytokines in biological psychiatry using commercially available multiplex immunoassays</atitle><jtitle>Psychoneuroendocrinology</jtitle><addtitle>Psychoneuroendocrinology</addtitle><date>2017-01-01</date><risdate>2017</risdate><volume>75</volume><spage>72</spage><epage>82</epage><pages>72-82</pages><issn>0306-4530</issn><eissn>1873-3360</eissn><abstract>Highlights • We compared two multiplex-cytokine detection technologies. • Both platforms performances were unequal depending on tested cytokines. • Healthy state is not synonymous of stability in blood circulating cytokines. • Caution is required to profile body fluid with multiplex technologies.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>27810706</pmid><doi>10.1016/j.psyneuen.2016.10.010</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-6519-8586</orcidid><orcidid>https://orcid.org/0000-0002-8997-0470</orcidid><orcidid>https://orcid.org/0000-0003-1222-6050</orcidid><orcidid>https://orcid.org/0000-0002-0909-4221</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0306-4530 |
ispartof | Psychoneuroendocrinology, 2017-01, Vol.75, p.72-82 |
issn | 0306-4530 1873-3360 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_01575039v1 |
source | ScienceDirect Journals (5 years ago - present) |
subjects | Biochemistry, Molecular Biology Cytokine Endocrinology & Metabolism Genomics Human health and pathology Inflammation Life Sciences Multiplex immunoassay Psychiatrics and mental health Psychiatry |
title | How to: Measuring blood cytokines in biological psychiatry using commercially available multiplex immunoassays |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T04%3A14%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=How%20to:%20Measuring%20blood%20cytokines%20in%20biological%20psychiatry%20using%20commercially%20available%20multiplex%20immunoassays&rft.jtitle=Psychoneuroendocrinology&rft.au=Belzeaux,%20Raoul&rft.date=2017-01-01&rft.volume=75&rft.spage=72&rft.epage=82&rft.pages=72-82&rft.issn=0306-4530&rft.eissn=1873-3360&rft_id=info:doi/10.1016/j.psyneuen.2016.10.010&rft_dat=%3Cproquest_hal_p%3E1836735994%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1836735994&rft_id=info:pmid/27810706&rft_els_id=S0306453016308022&rfr_iscdi=true |