Pedicle Screw Fixation Under Nonaxial Loads: A Cadaveric Study

An experimental study of pedicle screw fixation in human cadaveric vertebrae. The aim of this study was to experimentally characterize pedicle screw fixation under nonaxial loading and to analyze the effect of the surgeons' screw and placement choices on the fixation risk of failure. Pedicle sc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spine (Philadelphia, Pa. 1976) Pa. 1976), 2016-02, Vol.41 (3), p.E124-E130
Hauptverfasser: Bianco, Rohan-Jean, Aubin, Carl-Eric, Mac-Thiong, Jean-Marc, Wagnac, Eric, Arnoux, Pierre-Jean
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page E130
container_issue 3
container_start_page E124
container_title Spine (Philadelphia, Pa. 1976)
container_volume 41
creator Bianco, Rohan-Jean
Aubin, Carl-Eric
Mac-Thiong, Jean-Marc
Wagnac, Eric
Arnoux, Pierre-Jean
description An experimental study of pedicle screw fixation in human cadaveric vertebrae. The aim of this study was to experimentally characterize pedicle screw fixation under nonaxial loading and to analyze the effect of the surgeons' screw and placement choices on the fixation risk of failure. Pedicle screw fixation performance is traditionally characterized with axial pullout tests, which do not fully represent the various tridimensional loads sustained by the screws during correction maneuvers of severe spinal deformities. Previous studies have analyzed the biomechanics of nonaxial loads on pedicle screws, but their effects on the screw loosening mechanisms are still not well understood. A design of experiment (DOE) approach was used to evaluate 2 screw thread designs (single-lead and dual-lead threads), 2 insertion trajectories in the transverse and sagittal planes, and 2 loading directions (lateral and cranial). Pedicle screws were inserted in both pedicles of 12 cadaveric lumbar vertebrae for a total of 24 tests. Four sinewave loading cycles (0-400 N) were applied, orthogonally to the screw axis, at the screw head. The resulting forces, displacements, and rotations of the screws were recorded. In comparison to the other cycles, the first loading cycle revealed important permanent deformation of the bone (mean permanent displacement of the screw head of 0.79 mm), which gradually accumulated over the following cycles to 1.75 mm on average (plowing effect). The cranial loading direction caused significantly lower (P 
doi_str_mv 10.1097/BRS.0000000000001200
format Article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_01472616v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1765116205</sourcerecordid><originalsourceid>FETCH-LOGICAL-c290t-c2ca16780c81868fcf1a9cbdac00cdadaa33867029d89945b3705ac4997448783</originalsourceid><addsrcrecordid>eNpdkE9LAzEQxYMotla_gcge9bA1k93NHw9CLdYKRcXac0iTLEa2u7rZre23N6W1iHOYgeH33jAPoXPAfcCCXd-9Tvv4TwHB-AB1ISM8BsjEIerihJKYpAntoBPvPwJEExDHqENoxgAodNHtizVOFzaa6tp-RyO3Uo2rymhWGltHT1WpVk4V0aRSxt9Eg2iojFra2ulo2rRmfYqOclV4e7abPTQb3b8Nx_Hk-eFxOJjEmgjchK4VUMax5sApz3UOSui5URpjbYKlShJOGSbCcCHSbJ4wnCmdCsHSlDOe9NDV1vddFfKzdgtVr2WlnBwPJnKzw5AyQoEuIbCXW_azrr5a6xu5cF7bolClrVovgdEsPE9wFtB0i-q68r62-d4bsNykLEPK8n_KQXaxu9DOF9bsRb-xJj8rA3R4</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1765116205</pqid></control><display><type>article</type><title>Pedicle Screw Fixation Under Nonaxial Loads: A Cadaveric Study</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Bianco, Rohan-Jean ; Aubin, Carl-Eric ; Mac-Thiong, Jean-Marc ; Wagnac, Eric ; Arnoux, Pierre-Jean</creator><creatorcontrib>Bianco, Rohan-Jean ; Aubin, Carl-Eric ; Mac-Thiong, Jean-Marc ; Wagnac, Eric ; Arnoux, Pierre-Jean</creatorcontrib><description>An experimental study of pedicle screw fixation in human cadaveric vertebrae. The aim of this study was to experimentally characterize pedicle screw fixation under nonaxial loading and to analyze the effect of the surgeons' screw and placement choices on the fixation risk of failure. Pedicle screw fixation performance is traditionally characterized with axial pullout tests, which do not fully represent the various tridimensional loads sustained by the screws during correction maneuvers of severe spinal deformities. Previous studies have analyzed the biomechanics of nonaxial loads on pedicle screws, but their effects on the screw loosening mechanisms are still not well understood. A design of experiment (DOE) approach was used to evaluate 2 screw thread designs (single-lead and dual-lead threads), 2 insertion trajectories in the transverse and sagittal planes, and 2 loading directions (lateral and cranial). Pedicle screws were inserted in both pedicles of 12 cadaveric lumbar vertebrae for a total of 24 tests. Four sinewave loading cycles (0-400 N) were applied, orthogonally to the screw axis, at the screw head. The resulting forces, displacements, and rotations of the screws were recorded. In comparison to the other cycles, the first loading cycle revealed important permanent deformation of the bone (mean permanent displacement of the screw head of 0.79 mm), which gradually accumulated over the following cycles to 1.75 mm on average (plowing effect). The cranial loading direction caused significantly lower (P &lt; 0.05) bone deformation than lateral loading. The dual-lead screw had a significantly higher (P &lt; 0.05) initial stiffness than the single-lead thread screw. Nonaxial loads induce screw plowing that lead to bone compacting and subsequent screw loosening or even bone failure, thus reducing the pedicle screw fixation strength. Lateral loads induce greater bone deformation and risks of failure than cranial loads. N/A.</description><identifier>ISSN: 0362-2436</identifier><identifier>ISSN: 1528-1159</identifier><identifier>EISSN: 1528-1159</identifier><identifier>DOI: 10.1097/BRS.0000000000001200</identifier><identifier>PMID: 26571161</identifier><language>eng</language><publisher>United States</publisher><subject>Bioengineering ; Biomechanical Phenomena - physiology ; Humans ; Life Sciences ; Lumbar Vertebrae - physiology ; Materials Testing - instrumentation ; Materials Testing - methods ; Materials Testing - standards ; Pedicle Screws - standards ; Spinal Fusion - instrumentation ; Spinal Fusion - methods ; Spinal Fusion - standards ; Weight-Bearing - physiology</subject><ispartof>Spine (Philadelphia, Pa. 1976), 2016-02, Vol.41 (3), p.E124-E130</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c290t-c2ca16780c81868fcf1a9cbdac00cdadaa33867029d89945b3705ac4997448783</cites><orcidid>0000-0003-3806-7326 ; 0000-0002-0311-560X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26571161$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-01472616$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Bianco, Rohan-Jean</creatorcontrib><creatorcontrib>Aubin, Carl-Eric</creatorcontrib><creatorcontrib>Mac-Thiong, Jean-Marc</creatorcontrib><creatorcontrib>Wagnac, Eric</creatorcontrib><creatorcontrib>Arnoux, Pierre-Jean</creatorcontrib><title>Pedicle Screw Fixation Under Nonaxial Loads: A Cadaveric Study</title><title>Spine (Philadelphia, Pa. 1976)</title><addtitle>Spine (Phila Pa 1976)</addtitle><description>An experimental study of pedicle screw fixation in human cadaveric vertebrae. The aim of this study was to experimentally characterize pedicle screw fixation under nonaxial loading and to analyze the effect of the surgeons' screw and placement choices on the fixation risk of failure. Pedicle screw fixation performance is traditionally characterized with axial pullout tests, which do not fully represent the various tridimensional loads sustained by the screws during correction maneuvers of severe spinal deformities. Previous studies have analyzed the biomechanics of nonaxial loads on pedicle screws, but their effects on the screw loosening mechanisms are still not well understood. A design of experiment (DOE) approach was used to evaluate 2 screw thread designs (single-lead and dual-lead threads), 2 insertion trajectories in the transverse and sagittal planes, and 2 loading directions (lateral and cranial). Pedicle screws were inserted in both pedicles of 12 cadaveric lumbar vertebrae for a total of 24 tests. Four sinewave loading cycles (0-400 N) were applied, orthogonally to the screw axis, at the screw head. The resulting forces, displacements, and rotations of the screws were recorded. In comparison to the other cycles, the first loading cycle revealed important permanent deformation of the bone (mean permanent displacement of the screw head of 0.79 mm), which gradually accumulated over the following cycles to 1.75 mm on average (plowing effect). The cranial loading direction caused significantly lower (P &lt; 0.05) bone deformation than lateral loading. The dual-lead screw had a significantly higher (P &lt; 0.05) initial stiffness than the single-lead thread screw. Nonaxial loads induce screw plowing that lead to bone compacting and subsequent screw loosening or even bone failure, thus reducing the pedicle screw fixation strength. Lateral loads induce greater bone deformation and risks of failure than cranial loads. N/A.</description><subject>Bioengineering</subject><subject>Biomechanical Phenomena - physiology</subject><subject>Humans</subject><subject>Life Sciences</subject><subject>Lumbar Vertebrae - physiology</subject><subject>Materials Testing - instrumentation</subject><subject>Materials Testing - methods</subject><subject>Materials Testing - standards</subject><subject>Pedicle Screws - standards</subject><subject>Spinal Fusion - instrumentation</subject><subject>Spinal Fusion - methods</subject><subject>Spinal Fusion - standards</subject><subject>Weight-Bearing - physiology</subject><issn>0362-2436</issn><issn>1528-1159</issn><issn>1528-1159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkE9LAzEQxYMotla_gcge9bA1k93NHw9CLdYKRcXac0iTLEa2u7rZre23N6W1iHOYgeH33jAPoXPAfcCCXd-9Tvv4TwHB-AB1ISM8BsjEIerihJKYpAntoBPvPwJEExDHqENoxgAodNHtizVOFzaa6tp-RyO3Uo2rymhWGltHT1WpVk4V0aRSxt9Eg2iojFra2ulo2rRmfYqOclV4e7abPTQb3b8Nx_Hk-eFxOJjEmgjchK4VUMax5sApz3UOSui5URpjbYKlShJOGSbCcCHSbJ4wnCmdCsHSlDOe9NDV1vddFfKzdgtVr2WlnBwPJnKzw5AyQoEuIbCXW_azrr5a6xu5cF7bolClrVovgdEsPE9wFtB0i-q68r62-d4bsNykLEPK8n_KQXaxu9DOF9bsRb-xJj8rA3R4</recordid><startdate>20160201</startdate><enddate>20160201</enddate><creator>Bianco, Rohan-Jean</creator><creator>Aubin, Carl-Eric</creator><creator>Mac-Thiong, Jean-Marc</creator><creator>Wagnac, Eric</creator><creator>Arnoux, Pierre-Jean</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>1XC</scope><orcidid>https://orcid.org/0000-0003-3806-7326</orcidid><orcidid>https://orcid.org/0000-0002-0311-560X</orcidid></search><sort><creationdate>20160201</creationdate><title>Pedicle Screw Fixation Under Nonaxial Loads: A Cadaveric Study</title><author>Bianco, Rohan-Jean ; Aubin, Carl-Eric ; Mac-Thiong, Jean-Marc ; Wagnac, Eric ; Arnoux, Pierre-Jean</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c290t-c2ca16780c81868fcf1a9cbdac00cdadaa33867029d89945b3705ac4997448783</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Bioengineering</topic><topic>Biomechanical Phenomena - physiology</topic><topic>Humans</topic><topic>Life Sciences</topic><topic>Lumbar Vertebrae - physiology</topic><topic>Materials Testing - instrumentation</topic><topic>Materials Testing - methods</topic><topic>Materials Testing - standards</topic><topic>Pedicle Screws - standards</topic><topic>Spinal Fusion - instrumentation</topic><topic>Spinal Fusion - methods</topic><topic>Spinal Fusion - standards</topic><topic>Weight-Bearing - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bianco, Rohan-Jean</creatorcontrib><creatorcontrib>Aubin, Carl-Eric</creatorcontrib><creatorcontrib>Mac-Thiong, Jean-Marc</creatorcontrib><creatorcontrib>Wagnac, Eric</creatorcontrib><creatorcontrib>Arnoux, Pierre-Jean</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Spine (Philadelphia, Pa. 1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bianco, Rohan-Jean</au><au>Aubin, Carl-Eric</au><au>Mac-Thiong, Jean-Marc</au><au>Wagnac, Eric</au><au>Arnoux, Pierre-Jean</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pedicle Screw Fixation Under Nonaxial Loads: A Cadaveric Study</atitle><jtitle>Spine (Philadelphia, Pa. 1976)</jtitle><addtitle>Spine (Phila Pa 1976)</addtitle><date>2016-02-01</date><risdate>2016</risdate><volume>41</volume><issue>3</issue><spage>E124</spage><epage>E130</epage><pages>E124-E130</pages><issn>0362-2436</issn><issn>1528-1159</issn><eissn>1528-1159</eissn><abstract>An experimental study of pedicle screw fixation in human cadaveric vertebrae. The aim of this study was to experimentally characterize pedicle screw fixation under nonaxial loading and to analyze the effect of the surgeons' screw and placement choices on the fixation risk of failure. Pedicle screw fixation performance is traditionally characterized with axial pullout tests, which do not fully represent the various tridimensional loads sustained by the screws during correction maneuvers of severe spinal deformities. Previous studies have analyzed the biomechanics of nonaxial loads on pedicle screws, but their effects on the screw loosening mechanisms are still not well understood. A design of experiment (DOE) approach was used to evaluate 2 screw thread designs (single-lead and dual-lead threads), 2 insertion trajectories in the transverse and sagittal planes, and 2 loading directions (lateral and cranial). Pedicle screws were inserted in both pedicles of 12 cadaveric lumbar vertebrae for a total of 24 tests. Four sinewave loading cycles (0-400 N) were applied, orthogonally to the screw axis, at the screw head. The resulting forces, displacements, and rotations of the screws were recorded. In comparison to the other cycles, the first loading cycle revealed important permanent deformation of the bone (mean permanent displacement of the screw head of 0.79 mm), which gradually accumulated over the following cycles to 1.75 mm on average (plowing effect). The cranial loading direction caused significantly lower (P &lt; 0.05) bone deformation than lateral loading. The dual-lead screw had a significantly higher (P &lt; 0.05) initial stiffness than the single-lead thread screw. Nonaxial loads induce screw plowing that lead to bone compacting and subsequent screw loosening or even bone failure, thus reducing the pedicle screw fixation strength. Lateral loads induce greater bone deformation and risks of failure than cranial loads. N/A.</abstract><cop>United States</cop><pmid>26571161</pmid><doi>10.1097/BRS.0000000000001200</doi><orcidid>https://orcid.org/0000-0003-3806-7326</orcidid><orcidid>https://orcid.org/0000-0002-0311-560X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0362-2436
ispartof Spine (Philadelphia, Pa. 1976), 2016-02, Vol.41 (3), p.E124-E130
issn 0362-2436
1528-1159
1528-1159
language eng
recordid cdi_hal_primary_oai_HAL_hal_01472616v1
source MEDLINE; Journals@Ovid Complete
subjects Bioengineering
Biomechanical Phenomena - physiology
Humans
Life Sciences
Lumbar Vertebrae - physiology
Materials Testing - instrumentation
Materials Testing - methods
Materials Testing - standards
Pedicle Screws - standards
Spinal Fusion - instrumentation
Spinal Fusion - methods
Spinal Fusion - standards
Weight-Bearing - physiology
title Pedicle Screw Fixation Under Nonaxial Loads: A Cadaveric Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T12%3A27%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pedicle%20Screw%20Fixation%20Under%20Nonaxial%20Loads:%20A%20Cadaveric%20Study&rft.jtitle=Spine%20(Philadelphia,%20Pa.%201976)&rft.au=Bianco,%20Rohan-Jean&rft.date=2016-02-01&rft.volume=41&rft.issue=3&rft.spage=E124&rft.epage=E130&rft.pages=E124-E130&rft.issn=0362-2436&rft.eissn=1528-1159&rft_id=info:doi/10.1097/BRS.0000000000001200&rft_dat=%3Cproquest_hal_p%3E1765116205%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1765116205&rft_id=info:pmid/26571161&rfr_iscdi=true