Zernike ultrasonic tomography for fluid velocity imaging based on pipeline intrusive time-of-flight measurements

In this paper, we propose a novel ultrasonic tomography method for pipeline flow field imaging, based on the Zernike polynomial series. Having intrusive multipath time-offlight ultrasonic measurements (difference in flight time and speed of ultrasound) at the input, we provide at the output tomogram...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 2014-11, Vol.61 (11), p.1846-1855
Hauptverfasser: Besic, Nikola, Vasile, Gabriel, Anghel, Andrei, Petrut, Teodor-Ion, Ioana, Cornel, Stankovic, Srdjan, Girard, Alexandre, d'Urso, Guy