Uncommon Breast Tumor Attenuation Artifact on Radionuclide Ventriculography

A 39-year-old woman with locally advanced left breast cancer (T4 N0 M0) underwent equilibrium radionuclide ventriculography for baseline assessment of left ventricular function before neoadjuvant chemotherapy. The left ventricular ejection fraction was 76% at 75 beats per minute, without localized w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical nuclear medicine 2008-04, Vol.33 (4), p.288-289
Hauptverfasser: Metrard, Gilles, Girault, Sylvie, Capitain, Olivier, Jeanguillaume, Christian, Rakotonirina, Hervé, Berthelot, Cécile, Le Jeune, Jean-Jacques, Morel, Olivier
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 289
container_issue 4
container_start_page 288
container_title Clinical nuclear medicine
container_volume 33
creator Metrard, Gilles
Girault, Sylvie
Capitain, Olivier
Jeanguillaume, Christian
Rakotonirina, Hervé
Berthelot, Cécile
Le Jeune, Jean-Jacques
Morel, Olivier
description A 39-year-old woman with locally advanced left breast cancer (T4 N0 M0) underwent equilibrium radionuclide ventriculography for baseline assessment of left ventricular function before neoadjuvant chemotherapy. The left ventricular ejection fraction was 76% at 75 beats per minute, without localized wall motion abnormality. In the best septal left anterior oblique projection, a large photopenic “halo” surrounded the cardiac chambers, mimicking a pericardial effusion. In fact, this aspect resulted from an attenuation artifact by a large left breast tumor, as demonstrated by FDG-PET/CT imaging.
doi_str_mv 10.1097/RLU.0b013e3181662f5e
format Article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_00859142v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>68103274</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3334-8cfbbf0db8185f394186cb5a9cb76cab118da524adbd776bac10573cef637fea3</originalsourceid><addsrcrecordid>eNpdUF1rFDEUDaLYbes_EJknwYepuUkmyTyuxbbiglC6fQ1JJnFHM5M1yVj675uyiwUfLvfrnMPhIPQe8AXgXny-3WwvsMFAHQUJnBPfuVdoBR3lLSakf41WmHLa9oKTE3Sa8y-MgQNnb9EJSNpxLugKfd_ONk5TnJsvyelcmrtliqlZl-LmRZexPtapjF7b0tT5Vg_1tNgwDq65d3NJo11C_Jn0fvd4jt54HbJ7d-xnaHv19e7ypt38uP52ud60llLKWmm9MR4PRoLsPO0ZSG5Np3trBLfaAMhBd4TpwQxCcKMt4E5Q6zynwjtNz9Cng-5OB7VP46TTo4p6VDfrjXq-YSy7Hhj5CxX78YDdp_hncbmoaczWhaBnF5esuARMiWAVyA5Am2LOyfl_yoDVc-CqBq7-D7zSPhz1FzO54YV0TPhF9yGG4lL-HZYHl9TO6VB21SnGFAvSkuoZs7q1tYDRJzS6jWs</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68103274</pqid></control><display><type>article</type><title>Uncommon Breast Tumor Attenuation Artifact on Radionuclide Ventriculography</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Metrard, Gilles ; Girault, Sylvie ; Capitain, Olivier ; Jeanguillaume, Christian ; Rakotonirina, Hervé ; Berthelot, Cécile ; Le Jeune, Jean-Jacques ; Morel, Olivier</creator><creatorcontrib>Metrard, Gilles ; Girault, Sylvie ; Capitain, Olivier ; Jeanguillaume, Christian ; Rakotonirina, Hervé ; Berthelot, Cécile ; Le Jeune, Jean-Jacques ; Morel, Olivier</creatorcontrib><description>A 39-year-old woman with locally advanced left breast cancer (T4 N0 M0) underwent equilibrium radionuclide ventriculography for baseline assessment of left ventricular function before neoadjuvant chemotherapy. The left ventricular ejection fraction was 76% at 75 beats per minute, without localized wall motion abnormality. In the best septal left anterior oblique projection, a large photopenic “halo” surrounded the cardiac chambers, mimicking a pericardial effusion. In fact, this aspect resulted from an attenuation artifact by a large left breast tumor, as demonstrated by FDG-PET/CT imaging.</description><identifier>ISSN: 0363-9762</identifier><identifier>EISSN: 1536-0229</identifier><identifier>DOI: 10.1097/RLU.0b013e3181662f5e</identifier><identifier>PMID: 18356673</identifier><language>eng</language><publisher>United States: Lippincott Williams &amp; Wilkins, Inc</publisher><subject>Adult ; Breast Neoplasms - diagnostic imaging ; Diagnostic Errors - prevention &amp; control ; False Positive Reactions ; Female ; Humans ; Radionuclide Ventriculography - methods ; Ventricular Dysfunction, Left - diagnostic imaging</subject><ispartof>Clinical nuclear medicine, 2008-04, Vol.33 (4), p.288-289</ispartof><rights>2008 Lippincott Williams &amp; Wilkins, Inc.</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3334-8cfbbf0db8185f394186cb5a9cb76cab118da524adbd776bac10573cef637fea3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18356673$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-00859142$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Metrard, Gilles</creatorcontrib><creatorcontrib>Girault, Sylvie</creatorcontrib><creatorcontrib>Capitain, Olivier</creatorcontrib><creatorcontrib>Jeanguillaume, Christian</creatorcontrib><creatorcontrib>Rakotonirina, Hervé</creatorcontrib><creatorcontrib>Berthelot, Cécile</creatorcontrib><creatorcontrib>Le Jeune, Jean-Jacques</creatorcontrib><creatorcontrib>Morel, Olivier</creatorcontrib><title>Uncommon Breast Tumor Attenuation Artifact on Radionuclide Ventriculography</title><title>Clinical nuclear medicine</title><addtitle>Clin Nucl Med</addtitle><description>A 39-year-old woman with locally advanced left breast cancer (T4 N0 M0) underwent equilibrium radionuclide ventriculography for baseline assessment of left ventricular function before neoadjuvant chemotherapy. The left ventricular ejection fraction was 76% at 75 beats per minute, without localized wall motion abnormality. In the best septal left anterior oblique projection, a large photopenic “halo” surrounded the cardiac chambers, mimicking a pericardial effusion. In fact, this aspect resulted from an attenuation artifact by a large left breast tumor, as demonstrated by FDG-PET/CT imaging.</description><subject>Adult</subject><subject>Breast Neoplasms - diagnostic imaging</subject><subject>Diagnostic Errors - prevention &amp; control</subject><subject>False Positive Reactions</subject><subject>Female</subject><subject>Humans</subject><subject>Radionuclide Ventriculography - methods</subject><subject>Ventricular Dysfunction, Left - diagnostic imaging</subject><issn>0363-9762</issn><issn>1536-0229</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdUF1rFDEUDaLYbes_EJknwYepuUkmyTyuxbbiglC6fQ1JJnFHM5M1yVj675uyiwUfLvfrnMPhIPQe8AXgXny-3WwvsMFAHQUJnBPfuVdoBR3lLSakf41WmHLa9oKTE3Sa8y-MgQNnb9EJSNpxLugKfd_ONk5TnJsvyelcmrtliqlZl-LmRZexPtapjF7b0tT5Vg_1tNgwDq65d3NJo11C_Jn0fvd4jt54HbJ7d-xnaHv19e7ypt38uP52ud60llLKWmm9MR4PRoLsPO0ZSG5Np3trBLfaAMhBd4TpwQxCcKMt4E5Q6zynwjtNz9Cng-5OB7VP46TTo4p6VDfrjXq-YSy7Hhj5CxX78YDdp_hncbmoaczWhaBnF5esuARMiWAVyA5Am2LOyfl_yoDVc-CqBq7-D7zSPhz1FzO54YV0TPhF9yGG4lL-HZYHl9TO6VB21SnGFAvSkuoZs7q1tYDRJzS6jWs</recordid><startdate>200804</startdate><enddate>200804</enddate><creator>Metrard, Gilles</creator><creator>Girault, Sylvie</creator><creator>Capitain, Olivier</creator><creator>Jeanguillaume, Christian</creator><creator>Rakotonirina, Hervé</creator><creator>Berthelot, Cécile</creator><creator>Le Jeune, Jean-Jacques</creator><creator>Morel, Olivier</creator><general>Lippincott Williams &amp; Wilkins, Inc</general><general>Lippincott, Williams &amp; Wilkins</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>1XC</scope></search><sort><creationdate>200804</creationdate><title>Uncommon Breast Tumor Attenuation Artifact on Radionuclide Ventriculography</title><author>Metrard, Gilles ; Girault, Sylvie ; Capitain, Olivier ; Jeanguillaume, Christian ; Rakotonirina, Hervé ; Berthelot, Cécile ; Le Jeune, Jean-Jacques ; Morel, Olivier</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3334-8cfbbf0db8185f394186cb5a9cb76cab118da524adbd776bac10573cef637fea3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Adult</topic><topic>Breast Neoplasms - diagnostic imaging</topic><topic>Diagnostic Errors - prevention &amp; control</topic><topic>False Positive Reactions</topic><topic>Female</topic><topic>Humans</topic><topic>Radionuclide Ventriculography - methods</topic><topic>Ventricular Dysfunction, Left - diagnostic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Metrard, Gilles</creatorcontrib><creatorcontrib>Girault, Sylvie</creatorcontrib><creatorcontrib>Capitain, Olivier</creatorcontrib><creatorcontrib>Jeanguillaume, Christian</creatorcontrib><creatorcontrib>Rakotonirina, Hervé</creatorcontrib><creatorcontrib>Berthelot, Cécile</creatorcontrib><creatorcontrib>Le Jeune, Jean-Jacques</creatorcontrib><creatorcontrib>Morel, Olivier</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Clinical nuclear medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Metrard, Gilles</au><au>Girault, Sylvie</au><au>Capitain, Olivier</au><au>Jeanguillaume, Christian</au><au>Rakotonirina, Hervé</au><au>Berthelot, Cécile</au><au>Le Jeune, Jean-Jacques</au><au>Morel, Olivier</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Uncommon Breast Tumor Attenuation Artifact on Radionuclide Ventriculography</atitle><jtitle>Clinical nuclear medicine</jtitle><addtitle>Clin Nucl Med</addtitle><date>2008-04</date><risdate>2008</risdate><volume>33</volume><issue>4</issue><spage>288</spage><epage>289</epage><pages>288-289</pages><issn>0363-9762</issn><eissn>1536-0229</eissn><abstract>A 39-year-old woman with locally advanced left breast cancer (T4 N0 M0) underwent equilibrium radionuclide ventriculography for baseline assessment of left ventricular function before neoadjuvant chemotherapy. The left ventricular ejection fraction was 76% at 75 beats per minute, without localized wall motion abnormality. In the best septal left anterior oblique projection, a large photopenic “halo” surrounded the cardiac chambers, mimicking a pericardial effusion. In fact, this aspect resulted from an attenuation artifact by a large left breast tumor, as demonstrated by FDG-PET/CT imaging.</abstract><cop>United States</cop><pub>Lippincott Williams &amp; Wilkins, Inc</pub><pmid>18356673</pmid><doi>10.1097/RLU.0b013e3181662f5e</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0363-9762
ispartof Clinical nuclear medicine, 2008-04, Vol.33 (4), p.288-289
issn 0363-9762
1536-0229
language eng
recordid cdi_hal_primary_oai_HAL_hal_00859142v1
source MEDLINE; Journals@Ovid Complete
subjects Adult
Breast Neoplasms - diagnostic imaging
Diagnostic Errors - prevention & control
False Positive Reactions
Female
Humans
Radionuclide Ventriculography - methods
Ventricular Dysfunction, Left - diagnostic imaging
title Uncommon Breast Tumor Attenuation Artifact on Radionuclide Ventriculography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T14%3A27%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Uncommon%20Breast%20Tumor%20Attenuation%20Artifact%20on%20Radionuclide%20Ventriculography&rft.jtitle=Clinical%20nuclear%20medicine&rft.au=Metrard,%20Gilles&rft.date=2008-04&rft.volume=33&rft.issue=4&rft.spage=288&rft.epage=289&rft.pages=288-289&rft.issn=0363-9762&rft.eissn=1536-0229&rft_id=info:doi/10.1097/RLU.0b013e3181662f5e&rft_dat=%3Cproquest_hal_p%3E68103274%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68103274&rft_id=info:pmid/18356673&rfr_iscdi=true